DISCLAIMER: 
 

All technical content within this document can be modified without notice. The content of the document is a under continual renewal. 
For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal 
conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such 
as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use. 
 
 

OTHER REGULATIONS AND STANDARDS: 
 

WEEE

 INFORMATION

 

Disposal  of  old  electrical  and  electronic  equipment  (as  in  the  European  Union  and  other  European  countries  with  separate 
collection systems). 

 

This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it 

should  be  taken  to  an  applicable  collection  point  for  the  recycling  of  electrical  and  electronic  equipment.  If  the  product  is  disposed 
correctly,  you  will  help  prevent  potential  negative  environmental  factors  and  impact  of  human  health,  which  could  otherwise  be 
caused  by  inappropriate  disposal.  The  recycling  of  materials  will  help  to  conserve  natural  resources.  For  more  information  about 
recycling this product, please contact your local city office, your household waste disposal service or the shop where you purchased 
the product. 
 
 

R

ESTRICTION OF 

H

AZARDOUS 

S

UBSTANCES DIRECTIVE

 

 

The  device  respects  the  2002/95/EC  Directive  on  the  restriction  of  the  use  of  certain  hazardous  substances  in  electrical 
and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS). 

 
 

CE

 MARKING

 

 

The product conforms with the essential requirements of the applicable EC directives. 

 
 

 
 

Summary of Contents for HD67E10-A1

Page 1: ...com Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master...

Page 2: ...24 RETURN POLICY 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own...

Page 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and opera...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 4 of 24 EXAMPLE OF CONNECTION...

Page 5: ...dustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 5 of 24 CONNECTION SCHEME Figure 1 Connection scheme for HD67E10 A...

Page 6: ...er Supply Two directional information between EtherCAT bus and DeviceNet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F...

Page 7: ...MN67E10_ENG Revision 1 000 Page 7 of 24 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumpti...

Page 8: ...g on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is us...

Page 9: ...links quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherCAT comm green It blinks when EtherCAT communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in...

Page 10: ...the standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them whil...

Page 11: ...t be made using Connector8 of the HD67E10 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections...

Page 12: ...hat runs with Windows called SW67E10 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Page 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave DeviceNet Slave Converter in order to configure another device in the s...

Page 14: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Page 15: ...AT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 15 of 24 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insi...

Page 16: ...he DeviceNet Master section are In the field ID Device the address for the DeviceNet Slave is defined In the field Baudrate the velocity of the DeviceNet Master bus is defined In the field Number Byte...

Page 17: ...the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT varia...

Page 18: ...field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT variable is defined In the field Position the starting address of the EtherCAT array where th...

Page 19: ...thernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip...

Page 20: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progr...

Page 21: ...Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 21 of 24 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for H...

Page 22: ...ombination of the following HD67E10 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E10 EtherCAT Slave DeviceNet Slave Converter Order Co...

Page 23: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 24: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: