USE OF COMPOSITOR SW67E00: 

 

To  configure  the  Converter,  use  the  available  software  that  runs  with  Windows  called  SW67E00.  It  is  downloadable  on  the  site 
www.adfweb.com and its operation is described in this document. 

(This manual is referenced to the last version of the software present on 

our web site)

. The software works with MSWindows (XP, Vista, Seven, 8, 10, 11; 32/64bit). 

 

 

When launching the SW67E00, the window below appears (Fig. 2). 
 

 

 

Note: 
    It is necessary to have installed .Net Framework 4. 

 

 

 
 

Figure 2: Main window for SW67E00 

Summary of Contents for HD67E00-2-A1

Page 1: ...ster www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www adfweb com Product HD67E1...

Page 2: ...HNICAL SUPPORT 31 RETURN POLICY 31 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the pr...

Page 3: ...vice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave Serial Document code MN67E00_ENG Revision 1 001 Page 4 of 31 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave Serial Document code MN67E00_ENG Revision 1 001 Page 5 of 31 CONNECTION SCHEME Figure 1a Connection scheme for HD67E00 2 A1...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave Serial Document code MN67E00_ENG Revision 1 001 Page 6 of 31 Figure 1b Connection scheme for HD67E00 5 A1...

Page 7: ...ion between EtherCAT bus and Serial bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW6...

Page 8: ..._ENG Revision 1 001 Page 8 of 31 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 2...

Page 9: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used fo...

Page 10: ...links quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Serial comm green It blinks when a Serial request is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progre...

Page 11: ...standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them while th...

Page 12: ...t code MN67E00_ENG Revision 1 001 Page 12 of 31 RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a NULL MODEM cable a serial cable where t...

Page 13: ...ip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82...

Page 14: ...made using Connector8 of the HD67E00 x A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in...

Page 15: ...ns with Windows called SW67E00 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on ou...

Page 16: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave Serial Converter in order to configure another device in the same manne...

Page 17: ...he language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Page 18: ...herCAT Slave Serial Document code MN67E00_ENG Revision 1 001 Page 18 of 31 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside th...

Page 19: ...ed In the field Primary DNS the IP Address of the primary DNS server is defined In the field Secondary DNS the IP Address of the secondary DNS server is defined If the field Clear Data on EtherCAT fau...

Page 20: ...thernet are In the fields IP Address the IP address for Ethernet side of the converter is defined In the fields SubNet Mask the SubNet Mask for Ethernet side of the converter is defined In the fields...

Page 21: ...EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variable i...

Page 22: ...le is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT var...

Page 23: ...erCAT Slave Serial Document code MN67E00_ENG Revision 1 001 Page 23 of 31 ETHERCAT ESI FILE By pressing the EtherCAT ESI File button it is possible to save the ESI file for the EtherCAT side of the co...

Page 24: ...net cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of...

Page 25: ...ogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mor...

Page 26: ...h to send some simple commands over serial port Reading data from HD67E00 EtherCAT Ethernet by Array Request Byte Number Description 1 E 0x45 2 T 0x54 3 H 0x48 4 E 0x45 5 R 0x52 6 C 0x43 7 A 0x41 8 T...

Page 27: ...e Number Description 1 E 0x45 2 T 0x54 3 H 0x48 4 E 0x45 5 R 0x52 6 C 0x43 7 A 0x41 8 T 0x54 9 S 0x53 10 L 0x4C 11 A 0x41 12 V 0x56 13 E 0x45 14 W 0x57 15 0x2E 16 18 Position byte of the EtherCAT arra...

Page 28: ...rial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave Serial Document code MN67E00_ENG Revision 1 001 Page 28 of 31 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD67E0...

Page 29: ...ctors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Modbus port 2 RS232 5 RS485 Device Family HD67E00 EtherCAT Slave Serial Converter Order Code HD67E00 2 A1 EtherCAT...

Page 30: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...

Page 31: ...o the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Reviews: