background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual   

EnOcean / NMEA2000

 

 

Document code: MN67C73_ENG     Revision 1.000   Page 4 of 30

 

 

 
EXAMPLE OF CONNECTION: 

 

 

Summary of Contents for HD67C58-5-B2

Page 1: ...Product HD67C50 Serial www adfweb com Product HD67C52 Modbus Slave www adfweb com Product HD67C54 Modbus TCP Slave www adfweb com Product HD67C56 BACnet Slave www adfweb com Product HD67C57 CAN www ad...

Page 2: ...ICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the prod...

Page 3: ...ce can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean NMEA2000 Document code MN67C73_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EnOcean NMEA2000 Document code MN67C73_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1 Connection scheme for HD67C73 B2...

Page 6: ...haracteristics Electrical isolation between EnOcean and Power Supply Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGU...

Page 7: ...3_ENG Revision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Page 9: ...Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 NMEA2000 communication yellow Blinks when a NMEA2000 message is received Blinks quickly Boot state Blinks ver...

Page 10: ...Ethernet connection must be made using Connector2 of HD67C73 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms rel...

Page 11: ...or terminating the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch C is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m...

Page 12: ...tering and lighting Each device uses a unique ID for identification and one of the standardized profiles EEPs for data transmission Communication process may be secure or unsecure and may be unidirect...

Page 13: ...nverter use the available software that runs with Windows called SW67C73 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Window...

Page 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable EnOcean NMEA2000 Converter in order to configure another device in the same manner it...

Page 15: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Page 16: ...EnOcean NMEA2000 Document code MN67C73_ENG Revision 1 000 Page 16 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Page 17: ...2000 message is not received in this time the data on OPC UA side are set to 0xFF If the field Enable Peer to Peer is checked the gateway will mask the Source Address of the NMEA2000 messages received...

Page 18: ...MN67C73_ENG Revision 1 000 Page 18 of 30 Figure 4 EnOcean Access window ENOCEAN ACCESS By Pressing the EnOcean Set Access button from the main window for SW67C73 Fig 2 the window EnOcean Set Access a...

Page 19: ...evice is defined In the field Secure Type the type of EnOcean communication is defined In the field Key the key used for encryption of frames in Secure Mode is defined In the field Rolling Code the Ro...

Page 20: ...are In the field Rorg the type of EnOcean telegram is defined In the field Func the type of EnOcean instance is defined In the field Type the type of event is defined The means of the Variable fields...

Page 21: ...b ID is defined 2 0A 11 bits or 2 0B 29 bits In the field Dimension the number of byte of the COB from 1 to 8 is defined The field TimeOut is used for put at zero the data into internal array if the N...

Page 22: ...ng 5th byte of the NMEA2000 message In the field Byte6 insert the byte of the internal array where saving 6th byte of the NMEA2000 message In the field Byte7 insert the byte of the internal array wher...

Page 23: ...f byte of the COB from 1 to 8 is defined If the field OnChange is checked the frame is sent when the data from EnOcean change If the field OnCMD is checked the frame is sent when a EnOcean message is...

Page 24: ...ert the byte of the internal array where taking 6th byte of the NMEA2000 message In the field Byte7 insert the byte of the internal array where taking 7th byte of the NMEA2000 message In the field Byt...

Page 25: ...cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Di...

Page 26: ...gram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more...

Page 27: ...ustrial Electronic Devices ADFweb com S r l User Manual EnOcean NMEA2000 Document code MN67C73_ENG Revision 1 000 Page 27 of 30 Figure 9 Mechanical dimensions scheme for HD67C73 B2 MECHANICAL DIMENSIO...

Page 28: ...alid combination of the following HD67C73 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67C73 EnOcean NMEA2000 Converter Order Code HD6...

Page 29: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycli...

Page 30: ...he following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the...

Reviews: