ORDERING INFORMATIONS: 

 
The ordering part number is formed by a valid combination of the following:  

HD67B47 – B 2 

 
 

 

 

 

Connectors Type 

 

 

 

 

2: Fixed Screw Terminal 

 
 

 

 

 

Enclosure Type 

B: Modulbox 4M, 35mm DIN Rail mounting

 

 

 

 

 

Device Family 

 

 

 

 

HD67B47: OPC UA Server / SNMP Manager - Converter 

 
 

Order Code: 

HD67B47-B2 

-  

OPC UA Server / SNMP Manager - Converter 

 

 
 

ACCESSORIES: 

 
Order Code:  

AC34011 

-  

35mm

 

Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC  

Order Code:  

AC34012 

35mm

 

Rail

 

DIN - Power Supply 220/240V AC 50/60Hz – 24 V DC

 

Summary of Contents for HD67B23

Page 1: ...Modbus TCP Master www adfweb com Product HD67B30 Modbus TCP Slave www adfweb com Product HD67B31 Bacnet Master www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B33 CAN www adfwe...

Page 2: ...D TECHNICAL SUPPORT 24 RETURN POLICY 24 Pagina 2 di 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updat...

Page 3: ...ocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation as...

Page 4: ...ectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 4 of 24 EXAMPLE O...

Page 5: ...Fweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 5 of 24 Figure 1 Connection scheme f...

Page 6: ...following characteristics Up to 1500 bytes in reading and 1500 bytes in writing Two directional information between SNMP and OPC UA Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC o...

Page 7: ...r SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 7 of 24 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vma...

Page 8: ...device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with...

Page 9: ...ly Boot state Blinks very slowly 0 5Hz update in progress 2 OPC UA comm yellow Flashing OPC UA request OFF OPC UA request Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 SNMP c...

Page 10: ...T The Ethernet connection must be made using Connector3 of HD67B47 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norm...

Page 11: ...r use the available software that runs with Windows called SW67B47 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last v...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server SNMP Manager Converter in order to confi...

Page 13: ...here is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section C...

Page 14: ...9 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 14 of 24 In the section Software Settings it is possible to enable disable some keyboard s commands...

Page 15: ...his feature is used for going out of the net In the field DNS the DNS address is defined This field is required if the server address is define by URL and not IP Address In the field Port the port use...

Page 16: ...define the list of OPC UA variables to read write The means of the checkboxes inside the table are If the field Enable is checked the OPC UA variable is enabled In the field Type the data format of th...

Page 17: ...fined selectable or editable manually In the field OID the OID to read write from to the SNMP Agent device is defined In the field Type the type of data to read write String or Int is defined In the f...

Page 18: ...or the SNMP authentication is defined o In the field Auth Pass the password for the SNMP aithentication is defined o In the field Priv Pass the password for Privacy authentication is defined o In the...

Page 19: ...rn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are...

Page 20: ...C Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that...

Page 21: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 21 of 24 MECHANICAL DIMENSIONS Figure 8 Mech...

Page 22: ...art number is formed by a valid combination of the following HD67B47 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B47 OPC UA Server...

Page 23: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applic...

Page 24: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information abou...

Reviews: