background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

S7comm / EtherNet/IP Slave

 

 

Document code: MN67627_ENG     Revision 1.000   Page 4 of 30

 

 

 

EXAMPLES OF CONNECTION: 

 

 

 

 

 

Summary of Contents for HD67627-A1

Page 1: ...us TCP Slave www adfweb com Product HD67619 PROFIBUS Slave www adfweb com Product HD67620 IEC61850 Server www adfweb com Product HD67621 Serial www adfweb com Product HD67622 Modbus Slave www adfweb c...

Page 2: ...PORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you...

Page 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operatio...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 4 of 30 EXAMPLES OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1 Connection scheme for HD67627 A1...

Page 6: ...een Ethernet Power Supply Two directional information between EtherNet IP bus and S7comm bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C...

Page 7: ...7627_ENG Revision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption...

Page 8: ...n the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used...

Page 9: ...owered OFF Device not powered 2 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherNet IP comm green It blinks when EtherNet IP communica...

Page 10: ...verters must be made using Connector3 and or Connector4 of the HD67620 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Page 11: ...runs with Windows called SW67627 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Page 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable S7comm EtherNet IP Slave Converter in order to configure another device in the same ma...

Page 13: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Page 14: ...omm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 14 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside...

Page 15: ...IP Address Automatically DHCP for Cable Connection is checked DHCP for LAN connection is enabled If the field Enable DNS is checked DNS protocol is enabled In the field Primary DNS the IP Address of t...

Page 16: ...Mask the SubNet Mask for EtherNet IP side of the converter is defined In the fields Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box fi...

Page 17: ...ss of the PLC that contains the data to be read is defined In the field PLC Port the port used for S7comm communication is defined In the field PLC Type the family of the PLC is defined In the field R...

Page 18: ...Net IP memory array from which mapping the data read is defined In the field Start Bit is used for the Bit data It is possible to select the bit of the selected Position where mapping the data If the...

Page 19: ...In the field DB Number the number of the DB of the PLC to write is defined In the field PLC Area the memory area where the data is located inside the PLC is defined In the field PLC Add the starting...

Page 20: ...om S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 20 of 30 If the field Swap W is checked the words order is reversed In the field Mnemonic a description of t...

Page 21: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 o...

Page 22: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program...

Page 23: ...missioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In case of using a control system from an...

Page 24: ...the Comm Format Data SINT shall be selected as the data type RSLogix 5000 requires a configuration assembly instance Both modules do not provide a configuration assembly instance Therefore it is allo...

Page 25: ...trial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 25 of 30 4 After the configuration is completed the controller tags are cre...

Page 26: ...et IP Slave Document code MN67627_ENG Revision 1 000 Page 26 of 30 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP device it is possible to load the EDS fi...

Page 27: ...ial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 27 of 30 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD67...

Page 28: ...d combination of the following HD67627 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67627 S7comm EtherNet IP Slave Converter Order Code...

Page 29: ...tion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the rec...

Page 30: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...