NMEA 0183 / Modbus TCP Slave - Converter
Document code: MN67617_ENG Revision 1.000 Page 20 of 30
Figure 3b: “Set Communication
Modbus TCP
Slave” window
Figure 3c: “Set Communication
RS232” window
Figure 3d: “Set Communication
RS485 / RS422”
window
M
ODBUS
TCP
S
LAVE
:
This section is used to define the main parameters of Modbus TCP line. The means of
the fields are:
In the field “
IP Address
” the IP address of the converter is defined;
In the field “
SubNet
Mask
” the Subnet Mask of the converter is defined;
In the field “
Gateway
” the default gateway of the net is defined. This feature
can be enabled or disabled pressing the Check Box field. This feature is used
for going out of the net;
In the field “
Port
” the TCP port to use for Modbus TCP communication is
defined.
RS232:
This section is used to define the main parameters of RS232 line. The means of the
fields are:
If the field “
Enable RS232
” is checked, the serial port is enabled;
In the field “
Baudrate
” the baudrate for the serial line is defined;
In the field “
Parity
” the parity of the serial line is defined;
In the field “
Stop Bits
” the number of stop bits of the serial line is defined.
RS485
/
RS422:
This section is used to define the main parameters of RS485 / RS422 line. The
means of the fields are:
If the field “
Enable RS485 / RS422
” is checked, the serial port is enabled;
In the field “
Baudrate
” the baudrate for the serial line is defined;
In the field “
Parity
” the parity of the serial line is defined;
In the field “
Stop Bits
” the number of stop bits of the serial line is defined.