ADF Web HD67617-422-A1 User Manual Download Page 10

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

NMEA 0183 / Modbus TCP Slave - Converter

 

 

Document code: MN67617_ENG     Revision 1.000    Page 10 of 30 

 

 

LEDS: 

 
The device has got four LEDs that are used to give information of the functioning status. 
The various meanings of the LEDs are described in the table below.

 

 

LED 

Normal Mode 

Boot Mode 

1: Device State (green) 

Blinks slowly (~1Hz) 

Blinks quickly:

 Boot state 

Blinks very slowly (~0.5Hz):

 update in progress 

2: Ethernet Link (green) 

ON:

 Ethernet cable connected 

OFF:

 Ethernet cable disconnected 

ON:

 Ethernet cable connected 

OFF:

 Ethernet cable disconnected 

3: NMEA 0183 
communication (green) 

Blinks when NMEA 0183 frames are received 

Blinks quickly:

 Boot state 

Blinks very slowly (~0.5Hz):

 update in progress 

4: Modbus TCP 
communication (green) 

Blinks when Modbus TCP communication is 
running 

Blinks quickly:

 Boot state 

Blinks very slowly (~0.5Hz):

 update in progress 

 

 

 

Summary of Contents for HD67617-422-A1

Page 1: ...ww adfweb com product HD67514 Modbus TCP Master www adfweb com product HD67515 Modbus TCP Server Do you have an your customer protocol See the following links www adfweb com Product HD67003 Do you nee...

Page 2: ...RDS 29 WARRANTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is...

Page 3: ...s mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with...

Page 4: ...nic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 4 of 30 EXAM...

Page 5: ...com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figur...

Page 6: ...ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 6 of 30 Figure 1b Connec...

Page 7: ...cteristics electrical isolation between NMEA 0183 Modbus TCP Power Supply Modbus TCP Power Supply NMEA 0183 Multiple independent NMEA 0183 lines Mountable on Rail DIN Wide power supply input range 8 2...

Page 8: ...ument code MN67617_ENG Revision 1 000 Page 8 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC The consumption depends to the code of the device For more details see the two tabl...

Page 9: ...of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading...

Page 10: ...w LED Normal Mode Boot Mode 1 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet Link green ON Ethernet cable connected OFF Ethernet...

Page 11: ...120 resistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conducto...

Page 12: ...31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 12 of 30 RS422 For terminate the RS422 line with a 120 resistor it is necessary to put ON dip 1 for T...

Page 13: ...1 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 13 of 30 RS232 The connection from RS232 socket to a serial port must be made with a Null Modem cable a...

Page 14: ...ETHERNET The Ethernet connection must be made using Connector5 of HD67617 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Page 15: ...ITOR SW67617 To configure the Converter use the available software that runs with Windows called SW67617 It is downloadable on the site www adfweb com and its operation is described in this document T...

Page 16: ...ich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable NMEA 0183 Modbus TCP Slave Converter in order to...

Page 17: ...ton there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sect...

Page 18: ...8 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 18 of 30 In the section Software Settings it is possible to enable disable some keyboard s com...

Page 19: ...code MN67617_ENG Revision 1 000 Page 19 of 30 SET COMMUNICATION By Pressing the Set Communication button from the main window for SW67617 Fig 2 the window Set Communication appears Fig 3 The window is...

Page 20: ...d pressing the Check Box field This feature is used for going out of the net In the field Port the TCP port to use for Modbus TCP communication is defined RS232 This section is used to define the main...

Page 21: ...Figure 3d Set Communication RS485 2 window RS485 2 This section is used to define the main parameters of RS485 2 line The means of the fields are If the field Enable RS485 2 is checked the serial port...

Page 22: ...wing meanings If the field Enable is checked the NMEA 0183 sentence is enabled In the field Serial Channel the serial port from which the sentence will be received is defined In the field Sentence the...

Page 23: ...evice Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF...

Page 24: ...stance Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Opera...

Page 25: ...p is created automatically In relation to the configuration defined it is possible to have two different maps Data in reading Type Address Function Description Input Register 0 03 Position 0 1 of inte...

Page 26: ...IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 26 of 30 Figure 7a Mechanical dimension...

Page 27: ...com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 27 of 30 Figure 7b Mechanical...

Page 28: ...5mm DIN Rail mounting Serial Ports None 1 x RS232 2 x RS485 RS422 1 x RS232 1 x RS485 1 x RS422 Device Family HD67617 NMEA 0183 Modbus TCP Slave Converter Order Code HD67617 A1 NMEA 0183 Modbus TCP Sl...

Page 29: ...uropean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an a...

Page 30: ...wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information...

Reviews: