Industrial
Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO:
www.adfweb.com
Phone +39.0438.30.91.31
User Manual
PROFINET Master/ DeviceNet Slave
Document code: MN67B75_ENG Revision 1.000 Pagina 16 di 26
SET COMMUNICATION:
This section define the fundamental communication parameters of two buses,
PROFINET and DeviceNet.
By Pressing the “
Set Communication
” button from the main window of SW67B75
(Fig. 2) the window “Set Communication” appears (Fig. 3).
The means of the fields for “PROFINET Master” are:
In the fields “
IP Address
” the IP address for PROFINET side of the converter
is defined;
In the fields “
SubNet
Mask
” the SubNet Mask for PROFINET side of the
converter is defined;
In the fields “
Gateway
” the default gateway of the net is defined. This
feature can be enabled or disabled pressing the Check Box field. This feature
is used for going out of the net;
In the field "
Name of Station
" the name of PROFINET side of the converter
is defined.
The means of the fields for the “DeviceNet Slave” section are:
In the field “
ID Device
” the address for the DeviceNet Slave is defined;
In the field “
Baudrate
” the velocity of the DeviceNet Master bus is defined:
In the field “
Number Byte IN
” the number input bytes of DeviceNet Slave is
defined (max 455 bytes);
In the field “
Number Byte OUT
” the number output bytes of DeviceNet
Slave is defined (max 455 bytes).
Figure 3: “Set Communication” window