background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

 

User Manual   

Modbus Slave / Modbus TCP Master

 

 

Document code: MN67510_ENG     Revision 2.100    Page 7 of 33

 

 

 

Figure 1c: Connection scheme for HD67510-B2

 

Summary of Contents for HD67510

Page 1: ...RS232 RS485 USB Ethernet www adfweb com Product HD67118 RS232 RS485 Converter www adfweb com Product HD67119 USB RS485 Converter www adfweb com Product HD67038 RS485 RS232 Ethernet Converter CAN CANo...

Page 2: ...customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document not...

Page 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and opera...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 4 of 33 EXAMPLES OF CONNECTION...

Page 5: ...dustrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 5 of 33 CONNECTION SCHEME Figure 1a Connection scheme for HD67510...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 6 of 33 Figure 1b Connection scheme for HD67510 A1 422...

Page 7: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 7 of 33 Figure 1c Connection scheme for HD67510 B2...

Page 8: ...cteristics Triple isolation between Serial Power Supply Serial Ethernet Power Supply Ethernet Ethernet 10Base T 100Base T autosensing for Modbus TCP Mountable on 35mm Rail DIN Wide power supply input...

Page 9: ...2 100 Page 9 of 33 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device C...

Page 10: ...used for the normal working of the device With Dip1 of Dip Switch A at ON position is used for uploading the Project and or Firmware HD67510 B2 version The first with Dip2 of Dip Switch A at OFF posit...

Page 11: ...ot state Blinks very slowly 0 5Hz update in progress 2 Ethernet Link ON Ethernet cable connected OFF Ethernet cable disconnected ON Ethernet cable connected OFF Ethernet cable disconnected 3 Serial co...

Page 12: ...Mbps To connect the device to a Hub Switch the use of a straight cable is recommended To connect the device to a PC PLC other the use of a cross cable is recommended RS232 The connection from RS232 s...

Page 13: ...dip 1 ON like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p...

Page 14: ...odbus TCP Master Document code MN67510_ENG Revision 2 100 Page 14 of 33 RS422 For terminate the RS422 line with a 120 resistor it is necessary to put ON dip 1 for T line and or put ON dip 2 for R line...

Page 15: ...runs with Windows called SW67510 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Page 16: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable Modbus Slave Modbus TCP Master Converter in order to configure another device in the s...

Page 17: ...nge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possib...

Page 18: ...18 of 33 SET COMMUNICATION By Pressing the Set Communication button from the main window for SW67510 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in ord...

Page 19: ...Table every request that arrives on serial is transferred on TCP using TCP format of frame to the slave with the IP address defined in the Set Communication section MODBUS SLAVE This section is used t...

Page 20: ...Mask the Subnet Mask of the converter is defined In the field Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is use...

Page 21: ...he data of the columns have the following meanings In the field Data Type the type of Modbus data is defined In the field Address the address of the Modbus register to which address the requests on RT...

Page 22: ...er sends to the TCP Slave 192 168 0 19 the read request of Input Status address 100 Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the data on serial EXAMP...

Page 23: ...n the field IP Address TCP the IP address of the Modbus TCP slave device to which address the TCP requests is defined In the field Slave ID TCP the station ID of the Modbus TCP slave device to which a...

Page 24: ...2 The Converter sends to the TCP slave 192 168 0 19 the read write request using the TCP slave ID 1 Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the dat...

Page 25: ...ess defined in the Set Communication section EXAMPLE 1 Using the configuration of Figure 3 Step 1 A serial Modbus master do the request to the Converter to read write a register from the RTU Slave Add...

Page 26: ...hese instructions Turn OFF the Device Connect the RS232 Null Modem cable form your PC to the Converter Put Dip2 of Dip Switch A in ON position Select the COM port and press the Connect button Turn ON...

Page 27: ...e Ping button Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF...

Page 28: ...e the converter Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the m...

Page 29: ...S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 29 of 33 MECHANICAL DIMENSIONS Figure 12a Mechanical dimensions scheme for HD67510 A1 Figure 12b Mechani...

Page 30: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 30 of 33 Figure 12c Mechanical dimensions scheme for HD67510 B2...

Page 31: ...nting Device Family HD67510 Modbus Slave Modbus TCP Master Converter Order Code HD67510 A1 Modbus Slave Modbus TCP Master Converter Housing type A Terminal Blocks Connectors Order Code HD67510 A1 422...

Page 32: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 33: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: