background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

 

User Manual   

Modbus Slave / Modbus TCP Master

 

 

Document code: MN67510_ENG     Revision 2.100    Page 12 of 38

 

 

 

FUNCTION MODES: 

 
The device has got two function modes depending on the position of the ‘Dip-Switch A’. 

 

With ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. 

 

With ‘Dip1 of Dip-Switch A’ at “ON” position, is used for uploading the Project and/or Firmware. 

 

 

 
For the operations to follow for the updating, see ‘UPDATE DEVICE’ section. 
 
According to the functioning mode, the LEDs will have specific functions, see ‘LEDS’ section. 
 

 

 

 

 
 
 

Summary of Contents for HD67510-A1

Page 1: ...thers products see also the following links RS232 RS485 USB Ethernet www adfweb com Product HD67118 RS232 RS485 Converter www adfweb com Product HD67119 USB RS485 Converter www adfweb com Product HD67...

Page 2: ...38 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the mos...

Page 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and opera...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 4 of 38 EXAMPLES OF CONNECTION...

Page 5: ...dustrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 5 of 38 CONNECTION SCHEME Figure 1a Connection scheme for HD67510...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 6 of 38 Figure 1b Connection scheme for HD67510 A1 422...

Page 7: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 7 of 38 Figure 1c Connection scheme for HD67510 B2...

Page 8: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 8 of 38 Figure 1d Connection scheme for HD67510 Slim 232...

Page 9: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 9 of 38 Figure 1e Connection scheme for HD67510 Slim 485...

Page 10: ...ristics Triple isolation between Serial Power Supply Serial Ethernet Power Supply Ethernet Ethernet 10Base T 100Base T autosensing for Modbus TCP Mountable on 35mm Rail DIN Wide power supply input ran...

Page 11: ...8 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Consumption W VA H...

Page 12: ...modes depending on the position of the Dip Switch A With Dip1 of Dip Switch A at OFF position is used for the normal working of the device With Dip1 of Dip Switch A at ON position is used for uploadi...

Page 13: ...inks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet Link ON Ethernet cable connected OFF Ethernet cable disconnected ON Ethernet cable connected OFF Ethernet cable disconnec...

Page 14: ...nks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Modbus communication Blinks when are received Modbus response frames RS232 RS485 Blinks quickly Boot state Blinks very slowly 0 5Hz...

Page 15: ...n cat 5 up to 100 Mbps To connect the device to a Hub Switch the use of a straight cable is recommended To connect the device to a PC PLC other the use of a cross cable is recommended RS232 The connec...

Page 16: ...dip 1 ON like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p...

Page 17: ...odbus TCP Master Document code MN67510_ENG Revision 2 100 Page 17 of 38 RS422 For terminate the RS422 line with a 120 resistor it is necessary to put ON dip 1 for T line and or put ON dip 2 for R line...

Page 18: ...uns with Windows called SW67510 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on o...

Page 19: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable Modbus Slave Modbus TCP Master Converter in order to configure another device in the s...

Page 20: ...nge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possib...

Page 21: ...21 of 38 SET COMMUNICATION By Pressing the Set Communication button from the main window for SW67510 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in ord...

Page 22: ...Table every request that arrives on serial is transferred on TCP using TCP format of frame to the slave with the IP address defined in the Set Communication section MODBUS SLAVE This section is used t...

Page 23: ...Mask the Subnet Mask of the converter is defined In the field Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is use...

Page 24: ...he data of the columns have the following meanings In the field Data Type the type of Modbus data is defined In the field Address the address of the Modbus register to which address the requests on RT...

Page 25: ...er sends to the TCP Slave 192 168 0 19 the read request of Input Status address 100 Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the data on serial EXAMP...

Page 26: ...n the field IP Address TCP the IP address of the Modbus TCP slave device to which address the TCP requests is defined In the field Slave ID TCP the station ID of the Modbus TCP slave device to which a...

Page 27: ...2 The Converter sends to the TCP slave 192 168 0 19 the read write request using the TCP slave ID 1 Step 3 The slave TCP replies to the Converter with the data Step 4 The Converter sends back the dat...

Page 28: ...ess defined in the Set Communication section EXAMPLE 1 Using the configuration of Figure 3 Step 1 A serial Modbus master do the request to the Converter to read write a register from the RTU Slave Add...

Page 29: ...hese instructions Turn OFF the Device Connect the RS232 Null Modem cable form your PC to the Converter Put Dip2 of Dip Switch A in ON position Select the COM port and press the Connect button Turn ON...

Page 30: ...e Ping button Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF...

Page 31: ...e converter Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main...

Page 32: ...S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 32 of 38 MECHANICAL DIMENSIONS Figure 12a Mechanical dimensions scheme for HD67510 A1 Figure 12b Mechani...

Page 33: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 33 of 38 Figure 12c Mechanical dimensions scheme for HD67510 B2...

Page 34: ...ustrial Electronic Devices ADFweb com S r l User Manual Modbus Slave Modbus TCP Master Document code MN67510_ENG Revision 2 100 Page 34 of 38 Figure 12d Mechanical dimensions scheme for HD67510 Slim x...

Page 35: ...m DIN Rail mounting Slim 2M 35mm DIN Rail mounting Device Family HD67510 Modbus Slave Modbus TCP Master Converter Order Code HD67510 A1 Modbus Slave Modbus TCP Master Converter Housing type A Terminal...

Page 36: ...510_ENG Revision 2 100 Page 36 of 38 ACCESSORIES Order Code AC34107 Null Modem Cable Fem Fem D sub 9 Pin 1 5 m Order Code AC34114 Null Modem Cable Fem Fem D sub 9 Pin 5 m Order Code AC34011 Rail DIN P...

Page 37: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 38: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: