background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

J1939 / CAN - Converter 

 

Document code: MN67439_ENG     Revision 1.101  Page 1 of 33 

    Page 1 of 33 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 

User Manual 

Revision 1.101 
English 

 

J1939 / CAN – Converter 

(Order Code: HD67439) 

 

For Website information:  

www.adfweb.com?Product=HD67439

 

  

 

For Price information: 

www.adfweb.com?Price=HD67439

     

 

Benefits and Main Features: 

 

Very easy to configure 

 

Wide supply input range 

 

Electrical isolation 

 

Industrial temperature range: 

 

-40°C / 105°C  (-40°F / 221°F) 

For others Gateways / Bridges:  

 
J1939 to Modbus

  

See also the following links: 

www.adfweb.com?Product=HD67212

 (Modbus RTU) 

 
CANopen to Modbus

  

See also the following links: 

www.adfweb.com?Product=HD67001

 (Modbus RTU Master) 

www.adfweb.com?Product=HD67002

 (Modbus RTU Slave) 

www.adfweb.com?Product=HD67004

  (Modbus TCP Master) 

www.adfweb.com?Product=HD67005

  (Modbus TCP Slave) 

 
For others Gateways / Bridges:  
For 

CAN bus 2.0A

 and/or 

CAN bus 2.0B

 to 

Modbus

 

See also the following links: 

www.adfweb.com?Product=HD67011

  (Modbus RTU Slave) 

www.adfweb.com?Product=HD67012

  (Modbus RTU Master) 

www.adfweb.com?Product=HD67014

  (Modbus TCP Slave) 

www.adfweb.com?Product=HD67015

  (Modbus TCP Master) 

 
Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67439

Page 1: ...ing links www adfweb com Product HD67212 Modbus RTU CANopen to Modbus See also the following links www adfweb com Product HD67001 Modbus RTU Master www adfweb com Product HD67002 Modbus RTU Slave www...

Page 2: ...33 RETURN POLICY 33 Pagina 2 di 33 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the p...

Page 3: ...erlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Page 4: ...ronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 4 of 33 Page 4 of 33 EXAMPL...

Page 5: ...om Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 5 of 33 Page 5 of 33 CONNECTION SCHEME Figure 1a...

Page 6: ...ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 6 of 33 Page 6 of 33 Figure 1b Connectio...

Page 7: ...tors or AMP SuperSeal 1 5 connectors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof All the four series have these characteristics Triple 4kV isolation between Power S...

Page 8: ...e 8 of 33 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67439 Exx xxx 8V 26V 10V 40V Consumption at 2...

Page 9: ...cribed in the table below LED Normal Mode Boot Mode 1 USB link yellow ON USB cable inserted OFF USB cable not inserted ON USB cable inserted OFF USB cable not inserted 2 Device state green Blinks slow...

Page 10: ...the HD67439 E7x xxx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of J1939 line with a 120 resist...

Page 11: ...he HD67439 E7x xxx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of CAN line with a 120 resistor...

Page 12: ...w adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 12 of 33 Page 12 of 33 USB The USB port is used to start the converter in Boot Mode an...

Page 13: ...67439 To configure the Converter use the available software that runs with Windows called SW67439 It is downloadable on the site www adfweb com and its operation is described in this document This man...

Page 14: ...lder which contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable J1939 CAN Converter in order to configure...

Page 15: ...n there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sectio...

Page 16: ...he window Set Communication Setting appears Fig 3 The meaning of the fields of J1939 are In the field Baudrate the data rate of J1939 bus is defined In the field TimeOut Data s a time is defined When...

Page 17: ...t sends the frame is defined If the field Transport Protocol is checked the frame will use Transport Protocol functions it is used to send more than 8 bytes In the field Start Byte the starting byte t...

Page 18: ...ity and 7 is the lowest In the field Data Page the data page of the J1939 message is defined The value can be 0 or 1 usually it is 0 In the field PGN the PGN of the J1939 message to be written from CA...

Page 19: ...me from 1 to 8 is defined In the field Byte1 the offset of the internal array where saving byte 1 of the CAN frame is defined In the field Byte2 the offset of the internal array where saving byte 2 of...

Page 20: ...t code MN67439_ENG Revision 1 101 Page 20 of 33 Page 20 of 33 In the field TimeOut the time in ms of the timeout of the data is defined If a CAN frame is not received in this time all the data of the...

Page 21: ...of the internal array where taking byte 1 of the CAN frame is defined In the field Byte2 the offset of the internal array where taking byte 2 of the CAN frame is defined In the field Byte3 the offset...

Page 22: ...r Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 22 of 33 Page 22 of 33 If the field Time is checked the CAN frame is sent cyclically In the field Time ms the delay in ms bet...

Page 23: ...are if is necessary In order to load the parameters or update the firmware in the Converter follow these instructions Connect the AC67400 to the PC Connect the CAN port of AC67400 to a CAN port of HD6...

Page 24: ...guration into the device and also the Firmware if is necessary using the USB port In order to load the parameters or update the firmware in the device follow these instructions Connect the USB cable f...

Page 25: ...try to do the Update before require assistance try these points Check if the serial COM port selected is the correct one Check if the AC67400 is connected between the PC and the device Check if the US...

Page 26: ...onic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 26 of 33 Page 26 of 33 MECHA...

Page 27: ...l Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 27 of 33 Page 27 of...

Page 28: ...l Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 28 of 33 Page 28 of...

Page 29: ...l Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 29 of 33 Page 29 of...

Page 30: ...ONS The ordering part number is formed by a valid combination of the following HD67439 E y z s d f Fixing lugs A Type 1 B Type 2 C Type 3 D without fixing lugs J1939 Termination Y Terminated with 120...

Page 31: ...01 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC Order Code AC67402 Cable Super Seal 1 5 MALE 2 pole 1 0 Meter Order Code AC67402 3...

Page 32: ...opean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an app...

Page 33: ...wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information...

Reviews: