User Manual
PROFINET / M-Bus Master
Document code: MN67078_ENG Revision 1.100 Page 17 of 40
S
ECTION
V
ARIABLES
(B
Y
T
YPE
):
Selecting the desired node it is possible to add a variable.
In order to create a new variable it is necessary to fill
these items:
To use the created variable the field “
Enable
Variable
” must be checked. If you have created a
variable but for the moment it is unused it is
possible to uncheck the field “Enable Variable”
without delete it;
In the field “
Description
” it is possible to write a
description of the variable (it isn’t a necessary
information, it helps the readability of the tree of
network);
The field “
Type of Data
” is used to select the unit
of measure;
In the field “
VIF ASCII String
” insert the string of
VIF. It is possible to use this field only if the “Type
of Data” is “VIF is in ASCII”;
In the field “
Function Field
” it is necessary to
select the type of data;
The field “
Dimension
” is used to select the
dimension of the variable (8, 16, 24, 32, 32 real,
48, 64 bit, Variable Length);
In the field “
Length(Variable Len)
” insert the
length of the data in the case of the dimension is
“Variable Length”;
In the field “
Unit
” if it is necessary it is possible to select the unit of that variable. The Unit is used for indicates from which device
the data come;
If the field “
Scale
” is checked, the converter reserves a bytes on PROFINET array with Scale value (see page 26 for more info);
In the field “
Storage Number
” if it is necessary it is possible to insert the value of storage counter of that variable. With this field
the slave can indicate and transmit various stored counter states or historical values, in the order in which they occur;
In the field “
Tariff
” if it is necessary it is possible to insert the value of the tariff of that variable. The Tariff is used for indicates from
which device the data come;