ACK r Class
These registers are unlocked
Register 382 allows configuring the device for ACK requests as well as switching between LoRaWAN classes A & C.
When sending a frame to the network, the demonstrator can ask for an acknowledge (ACK) frame in return. When asking for an
acknowledge frame, the device is configured in
CONFIRMED
mode. Otherwise, it is configured in
UNCONFIRMED
mode.
By default, the device is configured in Class A (communication is asynchronous and initiated by the device) and can be
configured in Class C (device in continuous RX, communication can be initiated by the gateway)
Register Number
Description
Default Value
Range / Values
Comment
382
ACK r Class
0x00
0x00 = Class A unconfirmed
0x01 = Class A confirmed
0x10 = Class C unconfirmed
0x11 = Class C confirmed
All other
values are
RESERVED
3.3.8
Transmission periodicity
These registers are unlocked
Frames can be transmitted automatically by the device. The transmission periodicity in seconds can be set through the following
register:
Register Number
Description
Default Value
Range / Values
Comment
380
Frame TX periodicity
20
0-86400
In seconds
If the register is set to 0, periodic transmission is disabled. Frames can only be sent by pressing BTN1
3.3.9
Accelerometer
These registers are locked. In order to be unlocked, the following command must be sent:
ATT63 ROOT<CR>
The device’s accelerometer is configured by default to trigger whenever the device is shaken by hand. However, its configuration
can be modified to suit the user’s application. Two parameters can be changed:
-
The full scale, i.e. the maximum acceleration that the accelerometer will be able to detect
-
The detection threshold, i.e. the acceleration level above which the accelerometer will trigger
This can be done through registers 340 & 341:
Register Number
Description
Default Value
Range / Values
Comment
340
Full scale
8
2 to 16
Unit in g
341
Detection Threshold
2000
0 – (Full scale x 1000)
Unit in mg
The accelerometer can be deactivated or activated through register 330:
These registers are unlocked
Register Number
Description
Default Value
Range / Values
Comment
330
Accelerometer
activation
0x0001F007
0x0001F007 = Activate
accelerometer
All other
values are
RESERVED
0x0001F003 = deactivate
accelerometer