SIGFOX PULSE - Mode d’emploi / User guide version V1.5
31
Page
of 41
1.4.5 Meter compatibility
Examples of meters tested by Adeunis RF (non-exhaustive list)
Type
Name
Meter type
Water
Itron Flodis
Itron Cyble Sensor V2
Wehrle TRK-HYX / ETK-EAX
Wehrle Modularis
Sappel-Diehl Aquarius/Altair
Dhiel IZAR Pulse 3 & 4 wires
Gas
Elster BK
Elster IN-Z63
Electricity
Fludia FM250E and FM250M
Socomec Countis E00
Heat
Itron CF Echo II
2. Preparation and configuration
2.1. Dismantling the case
The product is supplied disassembled such that the lower electronic part can be accessed. This part is where the meter or meters are connected
to the screw terminals and where the configuration switches can be accessed.
Once connection of the meters has been finalised and configuration carried out, the case may be closed.
Please note
: once the case has been closed, opening it is no longer possible without the risk of losing the IP67 protection index guarantee.
2.2. Installation of the compression seal
Before connecting your meter cables to the product’s screw terminals, you must insert the compression gland nut and the appropriate seal for
your configuration.
3 types of seals are supplied with the SIGFOX PULSE: for a 5 mm diameter cable, for a 3 mm diameter cable, for 2 x 2.2 mm cables.
Seal for 1 x 5 mm cable
Seal for 1 x 3 mm cable
Seal for 2 x 2.2 mm cables
Assembly procedure:
107
90
27
49,50
1- Your meter and its
pulse interface.
2 - Pass the cable
through the compres-
sion gland nut.
3 - Pass the cable
through the compres-
sion gland seal
6 - Connect the ends
of the meter cable to
the screw terminals.
4 - Pass the cable
through the SIGFOX
PULSE’S case plate.
5 - Install the O-ring
seal on the case plate.