Page
16
/
28
2
RTU features mode description
2.1
RTU State Machine
2.1.1
State diagram
Figure 9: RTU state diagram
2.1.2
Idle and Nominal mode
At powerup or after a reset or the module enter idle mode. To allow IoT communication, the host controller must
send the Start RTU command (command code 0x01). In these states, the module reaches ultra low power
consumption while there is not command processing. The module is automatically wakeup by the char received
on its UART and returns to standby mode after the processing.
2.1.3
Command mode
Command mode is the configuration and test command state of the RTU module. Command mode may be
entered from Idle mode or Nominal mode by sending the Enter Command Mode command (command code
0xFE). In this mode, the RTU is not standby so there is no power saving while the module stays in this state. The
command format is based on AT style command which is an ASCII oriented format.
Nominal
mode
-
Comman
d mode
-
Configuration
& Test
command
Reset
ATO command
Idle mode
-
Waiting for a
start from
host
Start RTU
command
Stop RTU
command
Enter Command mode
command
Enter Command mode
command