8
–
*37
DOWNLOAD COMMAND ENABLES
0
Dialer
System
Not
Remote Remote
Remote UploadDownload
Shutdwn Shutdwn
Used
Bypass
Disarm
Arm
Program Program
See field 1*53 for Callback disable option; [1=enable];
0=disable; For Commercial Fire & UL installations, all
entries must be "0."
*38
PREVENT ZONE XXX BYPASS
[000]
| |
001-128; 00 if all zones can be bypassed
*39
ENABLE OPEN/CLOSE REPORT FOR
[1]
INSTALLER CODE
1=enable; 0=disable
*40
OPEN/CLOSE REPORT FOR KEYSWITCH
[0]
1=enable;
0=disable
*
41
NORMALLY CLOSED or EOLR (Zones 3-8)
[0]
1=N.C.loops; 0=EOLR supervision; Must be "0" for
Commercial Fire & UL.
*42
DIAL TONE PAUSE
[0]
0=5 seconds; 1=11 seconds; 2=30 seconds; Must be
"0" Commercial Fire & UL.
*43
DIAL TONE DETECTION
[1]
1=wait for true dial tone; 0=pause, then dial
*44
RING DETECTION COUNT
[00]
|
01-14; 15=answering machine; 00=no detection. Must
be "00" for Commercial Fire & UL Burglary.
*45
PRIMARY FORMAT
[0]
0=Low Speed; 1=Contact ID; 2=Ademco High
Speed
;
3=Ademco Express
*46
LOW SPEED FORMAT (Primary)
[0]
0=Ademco Low Speed; 1=Sescoa/Radionics
*47
SECONDARY FORMAT
[0]
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
*48
LOW SPEED FORMAT (Sec.)
[0]
0=Ademco Low Speed; 1=Sescoa/Radionics
*49
CHECKSUM VERIFICATION
[0] [0]
1=yes; 0=no
Prim
Sec
*50
SESCOA/RADIONICS SELECT
[0]
1=Sescoa; 0=Radionics
*51
DUAL REPORTING
[0]
1=yes; 0=no If used with Spilt Reporting "1" option (1*34),
alarms and alarm restores go to both primary & secondary
numbers, while all other reports go to secondary only. If used
with Split Reporting "2" option, alarms and alarm restores go
to both, open/close and test messages go to secondary only,
while all other reports go to primary. If used with Split
Reporting "3" option, fire alarms and fire supervisory signals
go to both primary and secondary, while all other reports go to
secondary only.
*52
STANDARD/EXPANDED REPORT FOR PRIMARY
[0 0 0 0 0 0]
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
0=standard; 1=expanded;
Note: Expanded overrides 4+2 format.
*53
STANDARD/EXPANDED REPORT FOR SECONDARY
[0 0 0 0 0 0]
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
0=standard; 1=expanded;
Note: Expanded overrides 4+2 format.
*56
USE LRR ONLY
[0]
0=No, 1=Yes, if built-in dialer will not be used.
*57
LRR IF DIALER FAILS
[0]
0=No, 1=Yes, if radio is to be used as a backup to dialer
*58
LRR ENABLE CS #1
[0 0 0 0 0 0]
Alrm Trbl Byp O/C Syst Tst
0=disable, 1=enable for reports for primary subs id of LRR
*59
LRR ENABLE CS#2
[0 0 0 0 0 0]
Alrm Trbl Byp O/C Syst Tst
0=disable, 1=enable for reports for secondary subs id of LRR
*64
PAGER INSTALLED
[0]
0=No, 1=Yes, alpha numeric pager interface is installed.
*65
PAGER PHONE # FOR ALARMS
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause
*66
PAGER ID # FOR ALARMS
Enter up to 10 digits for the pager id #
*67
PAGER PHONE # FOR TROUBLES
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause
*68
PAGER ID # FOR TROUBLES
Enter up to 10 digits for the pager id #
*69
PAGER PHONE # FOR BYPASSES
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause
*70
PAGER ID # FOR BYPASSES
Enter up to 10 digits for the pager id #