44 

Custom Word Substitutes for VIP Module Annunciation

A substitute word can be programmed for each of the 20 custom words used in your alpha zone descriptions.
The VIP Module will announce this substitute word in place of the custom word that is displayed on the
alpha keypad.  For example, an alarm display of "John's Bedroom" could be announced as "Son's Bedroom,"
since there is no annunciation for the custom word "John."  Note that if a substitute word is not assigned, the
VIP Module will not annunciate the zone descriptor at all, but will only annunciate the zone number.

To enter custom word substitutes, do the following:

1.

 

From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt.

2.

 

Press 0 (NO) to each menu option until the "CUSTOM INDEX ?" prompt is displayed.

CUSTOM  INDEX ?
0=no              1=yes

Enter 1 at this prompt.

CUSTOM WORD NO.
00=QUIT

Enter the custom word number (01-20) for which a voice
substitute is desired.  Enter 00 to quit this Programming Mode.

Press [

] to accept entry.

01  ENTER INDEX #

Enter the 3-digit substitute word index number from the relay
voice descriptor and custom word substitutes vocabulary list
found in the Relay Voice Descriptors part of this section.

Press [

] to accept entry.

The "CUSTOM WORD NO." prompt will be displayed.  Enter
the next custom word number to be substituted or enter 00 to
quit.

RF Serial Number Clear Mode

This mode may be used in the event that an undesired transmitter has been enrolled during sequential
enrolling, causing each subsequent serial number to be assigned to an incorrect zone.  Performing this
operation will delete all RF serial numbers, leaving all other zone information intact.  You may then return
to Sequential Mode to re-enroll wireless transmitters.

The RF Serial Number Clear Mode will 

not 

delete polling loop serial numbers.

To clear all RF wireless serial numbers, do the following:

1.

 

Enter Data Field Programming Mode: [Installer Code] + 8 0 0 0.

2.

 

From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt.

3.

 

Press 0 (NO) repeatedly until the "CLEAR RF SERIAL #?" prompt appears.

CLEAR RF SERIAL#?
1 = YES, 0 = NO      0

Enter 1 to clear all RF wireless serial numbers.  The "ARE
YOU SURE?" prompt is displayed as follows:

ARE YOU SURE?
1 = YES, 0 = NO    0

Enter 1 to clear all RF serial numbers.  Re-enter the Sequential
Mode to enroll wireless transmitters.

Summary of Contents for Vista-128FB  

Page 1: ...V128FB PRV1 10 98 9 9 6 67 7 RPPHUFLDO LUH DQG XUJODU 3DUWLWLRQHG 6HFXULW 6 VWHP ZLWK 6FKHGXOLQJ 4XLFN 6WDUW XLGH FIRE FIRE PULL Previous Menu...

Page 2: ...2...

Page 3: ...ontrol and is set to device address 00 Single Partition System The system default is for a single partition system Use the VISTA 128FB SINGLE PARTITION PROGRAMMING FORM when programming for single par...

Page 4: ...detailed instructions 5 Use 93 Menu Mode for device programming Refer to the DEVICE PROGRAMMING section to assign keypad ID numbers and default partitions for each keypad and to selectively suppress...

Page 5: ...g the Installer s code use 98 The only way to re access programming mode is by depressing both the and keys at the same time within 30 seconds of power up Exiting by using 99 always allows reentry int...

Page 6: ...ific 89 Communications 90 Partition Specific 1 01 93 Menu Mode 1 02 93 Menu Mode 1 03 93 Menu Mode 1 04 93 Menu Mode 1 05 93 Menu Mode 1 06 93 Menu Mode 1 07 93 Menu Mode 1 08 93 Menu Mode 1 09 93 Men...

Page 7: ...2 6 12 hrs 0 normal report about 2 min after AC loss Must be 2 for Central and Remote Station Fire alarm systems 20 VIP MODULE PHONE CODE Enter 01 09 for the first digit enter 00 11 11 for or 12 for...

Page 8: ...er reports go to secondary only If used with Split Reporting 2 option alarms and alarm restores go to both open close and test messages go to secondary only while all other reports go to primary If us...

Page 9: ...Commercial Fire UL installations 1 19 ARMS LOBBY 0 Enter 1 if arming this partition attempts to arm lobby enter 0 if it does not Must be 0 for Commercial Fire UL installations 1 20 EXIT ERROR LOGIC 0...

Page 10: ...d 56 1 75 RELAY TIMEOUT YY SECONDS 000 Enter the relay timeout 0 127 seconds desired for 80 Menu Mode time driven event relay command numbers 05 10 and 93 Menu Mode Relay Programming command 57 1 76 A...

Page 11: ...DELAY for ZONE TYPES 17 18 00 Waterflow FIre Supv Enter 00 15 times 2 seconds 3 17 ALTERNATE FUNCTION TAMPER 0 FOR ZONE 6 0 disabled 1 enabled 3 18 EXTENDED DELAY FOR TYPES 17 18 0 0 No 1 Yes 3 19 ENA...

Page 12: ...to next page of program fields press 94 To return to previous set of fields press 99 To erase account phone number field entries press field number To assign zone descriptors press 93 follow menu pro...

Page 13: ...nes can be bypassed 39 ENABLE OPEN CLOSE REPORT 1 FOR INSTALLER CODE 1 enable 0 disable 84 SWINGER SUPPRESSION 03 01 15 alarms Must be 00 disabled for Commercial Fire UL installations 85 ENABLE DIALER...

Page 14: ...ity to the installetion 0 disable 1 enable 2 18 ENABLE GOTO FOR THIS PARTITION 0 1 Allow log on from other partitions 0 disable 2 20 ENABLE J7 TRIGGERS by PARTITION 1 0 disable for displayed partition...

Page 15: ...assignment for zone Input device type for zone whether RF polling loop etc Enrolling serial numbers of 5800 Series transmitters and serial polling loop devices into the system all other zone characte...

Page 16: ...ramming part of this section for programming alpha descriptors The following is a list of commands used while in the Menu Mode 93 Menu Mode Key Commands 93 Enters Menu Mode Serves as ENTER key Press t...

Page 17: ...to continue or press the key to back the system up to the PROGRAM TOOL prompt ENTER ZN NO 000 QUIT 010 Zone 010 entered Enter the 3 digit zone number to be programmed protection zones 001 032 relay zo...

Page 18: ...its which will result in arming the system in the STAY or AWAY mode or disarming of the system depending on the selection made Press to continue 010 ACCESS POINT 00 31 01 If response type 27 was selec...

Page 19: ...DDR 01 31 01 If input type 09 was selected this prompt will be displayed Enter the ECP address of the keypad that is being used for entry exit for this access point 01 31 010 ACS ZONE NO 00 31 01 If i...

Page 20: ...sed Enter 0 NO to enroll later If 0 is entered the system will advance to the summary screen prompt 3 4 1 2 ALWAYS USE LOOP 5801 ENROLL AS UR OR RF LOOP 1 5802 5802CP ENROLL AS BR LOOP 1 5802MN ENROLL...

Page 21: ...ring this step you may press the key on the keypad or the upper left hand button of the program tool if you are satisfied with the serial and loop number combination that has been enrolled regardless...

Page 22: ...e TECHNOLOGY TYPE prompt PROGRAM TOOL 0 NO 1 YES 0 If a program tool is being used enter 1 If not using a tool enter 0 When a 0 is entered the system will advance to the TECHNOLOGY TYPE prompt 000 INP...

Page 23: ...u do not wish to enroll the zone displayed press on the keypad or the upper right hand button on the program tool a long beep will be heard to verify The following prompt will appear 010 LEARN S N 0 N...

Page 24: ...s have been displayed whether enrolled or not the ENTER ZN NO prompt will appear Enter 000 to exit the Sequential Mode and return to Data Field Programming Mode When you have finished programming all...

Page 25: ...of the Alarm Report code Press to continue ENTER ZONE NO 000 QUIT 001 Enter the zone number for which you are entering the report code When all zone Alarm Codes have been programmed enter 000 to Quit...

Page 26: ...er 000 Press to continue QUIT REPORT MENU 1 YES 0 NO 0 If you have completely finished entering report codes press 1 Y to quit Report Code Programming If you wish to enter other system report codes en...

Page 27: ...ort Code Programming If you wish to enter other system report codes enter 0 N Press to continue System Group 3 Codes SYSTEM GROUP 3 1 YES 0 NO 0 To enter System Group 3 codes press 1 Y EARLY OPEN 1st...

Page 28: ...at are selected from a vocabulary of 244 words stored in memory and any word can have an s or s added to it NOTE Due to the use of 3 digit zone numbers the first word of the descriptor is limited to 6...

Page 29: ...s follows Assume for example that the desired description for Zone 1 is BACK DOOR a Press followed by the 3 digit number of the first word from the fixed dictionary shown later in this section e g 0 1...

Page 30: ...d word enter 02 and so on A cursor will now appear at the beginning of the second line 3 Type the word using one of two methods as follows a Press followed by the 2 digit entry for the first letter yo...

Page 31: ...oceed as follows 1 Select Default Screen Mode The keypad will ask for the partition number for this message Enter the partition number Press to accept entry The following will appear DISARMED READY TO...

Page 32: ...118 LIGHT 119 LINE 120 LIQUOR 121 LIVING 122 LOADING 123 LOCK 124 LOOP 125 LORRA 126 LOW 127 LOWER 128 MACHINE 129 MAGNETIC 130 MAIDS 131 MAIN 132 MASTER 133 MAT 134 MEDICAL 135 MEDICINE 136 MICROWAV...

Page 33: ...g 01 30 Press to accept entry Note Device Address 04 must be used for the 4285 4286 Voice Module if one is installed If not it can be used for another device type Device Address 00 is always set as an...

Page 34: ...ve users with access to multiple partitions the ability to arm and disarm those partitions from it To enable this keypad for global arming disarming enter 1 To prevent the ability to use this keypad f...

Page 35: ...ing N Y N Press for NO answer Y Press SHIFT Y for YES answer SHIF T Press before pressing a SHIFT key function Will light READY LED LED goes out once a key is pressed Press again for each SHIFT functi...

Page 36: ...ion Enter N for private system users skip to Question 7 CS ID 11 Enter the primary central station s system ID number 1 7F will not be displayed for private system users BAT PRESENT Y N N Enter Y if o...

Page 37: ...ions are available 1 EVENT EV is the condition alarm fault trouble that must occur to a zone or group of zones zone list in order to activate the device These conditions apply only when a zone list is...

Page 38: ...E SYSTEM OPERATION ZT Instead of using a RESTORE ZONE LIST a specific zone response type or system operation action can be selected to de activate the device If a specific ZONE TYPE is chosen any zone...

Page 39: ...es Choices for Start Stop System Operation 00 No Response Not Used 01 Entry Exit 1 02 Entry exit 2 03 Perimeter 04 Interior Follower 05 Trouble Day Alarm Night 06 24 Hr Silent 07 24 Hr Audible 08 24 H...

Page 40: ...any partition Enter 1 8 for specific partition number Press to continue RELAY GROUP Relays may be grouped for common activation by time driven events commands 06 10 Enter 0 no group or 1 8 for a spec...

Page 41: ...ne would be 601 Program this zone for response type 19 24 Hr Trouble in Zone Programming Zone List Programming After all relays have been programmed upon entering 00 at the ENTER RELAY NO prompt you w...

Page 42: ...l the RLY VOICE DESCR prompt is displayed Follow the instructions below While in this mode press to advance to next screen Press to back up to previous screen RLY VOICE DESCR 0 no 1 yes Press 1 to pro...

Page 43: ...Five 074 Floor 029 Four 073 Fourth 217 Foyer 137 Word Index Front 087 Garage 023 Gas 138 Glass 139 Hall 050 Heat 010 Inside 209 Kitchen 022 Laundry 140 Left 027 Library 141 Light 019 Living 030 Loadi...

Page 44: ...the relay voice descriptor and custom word substitutes vocabulary list found in the Relay Voice Descriptors part of this section Press to accept entry The CUSTOM WORD NO prompt will be displayed Ente...

Page 45: ...This will further simplify the programming process PARTITIONS Partition Descriptor 4 char max Prim Sub Sec Sub Alpha Default Message 32 character maximum Partition 1 Partition 2 Partition 3 Partition...

Page 46: ...increments Console Annunciation During Entry Console Annunciation During Exit Confirmation of Arming Ding for Bell 1 Confirmation of Arming Ding for Bell 2 Aux Rly Chime on Bell 1 Chime on Bell 2 Aux...

Page 47: ...6 22 07 23 08 24 09 25 10 26 11 27 12 28 13 29 14 30 15 31 Type 0 Device Not Used 1 Alpha Console 3 RF Receiver 4 Output Relay Module 5 Voice Module 6 Long Range Radio 9 Vista Gateway Module Console S...

Page 48: ...el Open Close 2 Digit User Global Arm Auth Level Open Close 2 Digit User Global Arm Auth Level Open Close ACCESS CODES USER DEFINITIONS FOR PARTITIONS 7 8 4 digit Access Partition 7 Partition 8 Securi...

Page 49: ...No Zone Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 01 02 03 04 05 06 07 08 09 010 011 012 013 0...

Page 50: ...one Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 025 026 027 028 029 030 031 032 033 034 035 036 0...

Page 51: ...Zone Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 049 050 051 052 053 054 055 056 057 058 059 060...

Page 52: ...one Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 073 074 075 076 077 078 079 080 081 082 083 084 0...

Page 53: ...one Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 097 098 099 100 101 102 103 104 105 106 107 108 1...

Page 54: ...5 126 127 128 ZONE DEFINITIONS FOR KEYPAD PANIC ZONES 995 996 999 Enter yes no for each partition field 22 Zone No Zone Type 1 2 3 4 5 6 7 8 Bell Rel Act Report Code Zone Information part numbers Alph...

Page 55: ...Code Zone Information part numbers Alpha Descriptor 3 words max Zone No Zone Type Report Code Zone Information part numbers Alpha Descriptor 3 words max 601 617 602 618 603 619 604 620 605 621 606 62...

Page 56: ...Fire Waterflow 22 disarm 02 entry exit 2 08 24 hour auxiliary 18 Fire Supervisory 23 no alarm response 03 perimeter 09 supervised fire 19 24 hour trouble 27 access control 04 interior follower 10 inte...

Page 57: ...he installation instructions as you enter the data during the displays and prompts that appear in sequence Note The Device Programming section must be programmed for the device address Set the dip swi...

Page 58: ...s list device action will START STOP ZONE LIST Upon restore of ALL zones on this list device action will STOP It need not be same list as used for START ZT ZONE TYPE SYSTEM OPERATION Choices for Zone...

Page 59: ...ed in the 93 Menu Mode in the Relay Programming Section Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the disp...

Page 60: ...week and holidays Holidays 1 Yes 0 No 0 For defining up to 16 holidays for which partitions they apply Timed Events 1 Yes 0 No 0 For defining up to 20 time driven events with the following parameters...

Page 61: ...6 17 18 19 20 Keep this worksheet handy as you will be asked for a given time window number later in this section Since the time windows are shared among all partitions it is important to make sure th...

Page 62: ...ear in sequence HOL Partition Month Day 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Time Driven Event Worksheet The system provides up to 20 time driven events that can be programmed for th...

Page 63: ...er for commands 20 24 is Partition s Activation times 1 Beginning 2 End 3 During are the only valid choices for auto arming and disarming functions 20 Arm Stay 21 Arm Away 22 Disarm 23 Force Arm Stay...

Page 64: ...r each partition Enter the temporary scheduling mode by pressing Installer Code 81 Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you ent...

Page 65: ...tart Time HH MM Stop Time HH MM 6 Disarm Window Start Time HH MM Stop Time HH MM Arm Window Start Time HH MM Stop Time HH MM 7 Disarm Window Start Time HH MM Stop Time HH MM Arm Window Start Time HH M...

Page 66: ...66...

Page 67: ...ERFACE TO 5140DLM MAIN DIALER ON HOOK VOLTAGE THRESHOLD INTACT 25V CUT 13V BACK UP DIALER EARTH GROUND SCREW wire to main PCB terminal 30 J2 VOLTAGE TRIGGERS See instructions for trigger use and progr...

Page 68: ...9 359 l V128FB PRV1 10 98 165 Eileen Way Syosset NY 11791 Copyright 1998 PITTWAY Corporation...

Reviews: