Section 3 - Installing the Control 

3-25 

}

ECHELON NETWORK
(PASSPOINT ACS)

YELLOW

RED

BLACK

PROM C

TRANSFORMER

4-PIN

KEYPAD

PLUG

}

TO
CONTROL’S
KEYPAD 
TERMINALS

GREEN

 

Figure 3-32:  Wiring the VISTA Gateway Module 

 

 

 

 

 

 

 

 

 

 

 

 

Event Log Connections 

This system has the ability to record up to 512 events of 
various categories in the Event Log (history log).  Each 
event is recorded with the time and date of its 
occurrence (if real-time clock is set).  These categories 
are Alarm, Supervisory/Check, Bypass, Open/Close, and 
System conditions. The log may be viewed on an alpha 
keypad, or printed on a parallel or serial printer.  

NOTE: If you are using a parallel printer you must use 
the VA8201 Alpha Pager Module. 

Printer Configurations 

Configure the serial printer as follows: 

• 

7 data bits, even parity, 1 stop bit 

• 

1200 baud 

 

 

• 

When using a printer, field 14 must be 
programmed for RS232 input (1). Zone 9 
can longer be used as a protection zone. 

• 

If you are using a serial printer, terminal 23 
on the control panel cannot be used to 
interface with Automation software

 

Using the Alpha Pager Module (APM) 

To connect a printer using the Alpha Pager Module, 
perform the following steps: 

Step Action 

Connect the APM to the control (see 
Installing the Alpha Pager Module 
previously in this section). 

Connect the printer according to the 
instructions that accompany the APM. 

 

Using the 4100SM 

To connect a serial printer using the 4100SM, refer to 
Figure 3-33 and perform the following steps: 

Step Action 

Connect terminal 23 on the control panel to 
terminal 3 on the 4100SM. 

Step Action 

Connect terminal 6 on the 4100SM to the 
Brown wire on the 4142TR cable.  

Connect the 4142TR cable to J8 on the 
control. 

Connect terminals 8 and 7 of the 4100SM to 
terminals 6 and 7 (aux. power (+) and (-)), 
respectively of the control. 

Connect the UL EDP Listed serial printer to 
the 4100SM Interface Module. 

NOTES:  

The 4100SM Module is supplied with a 10-
foot RS232 cable.  A longer cable can be used 
if the VISTA-128B PLUS is separated from 
the serial printer by more than 10 feet, but 
the total cable length should be less than 50 
feet. 

See the 4100SM Installation Instructions for 
details concerning the serial printer 
operation. 

23

1

2

3

4

5

6

7

8

9

NU

CONTROL

PANEL

J8 CONNECTOR

VIOLET

GREY

YELLO

W

RED

GREEN

BR

O

W

N

BLUE

BLA

C

K

IN 2

IN 3

GR

OUND

OUT 5

OUT 6

GR

OUND

GR

OUND

PR

IN

TER

 D

TR

4142TR CABLE (SUPPLIED WITH 4100SM)

8

7

6

5

4

3

2

1

4100SM SERIAL MODULE

+ PWR

- (GND)

RXD

not used

not used

TXD

not used

DTR

BLUE WHITE

To TB6 Aux. Power (+)

(25mA current draw)

To TB7 Aux. Power (-)

USE GENDER CHANGER

SUPPLIED WITH 4100SM

IF PRINTER HAS DB25

MALE CONNECTOR

3M

Cable

Supplied with

4100SM

SERIAL PRINTER
SET FOR: 8 DATA BITS

EVEN PARITY
STOP BIT
300/1200 BAUD

4100SM JUMPERS
(CUT TO SET RESPECTIVE SIGNAL FLOATING)

COLOR

FUNCTION

PIN #

RED

BLUE

WHITE

CD

CTS
DSR

8
5
6

RED

4100SM-010-V0

 

Figure 3-33:  Printer Connections to the 4100SM 

Summary of Contents for Vista-128B PLUS

Page 1: ...JODU 3DUWLWLRQHG 6HFXULW 6 VWHP ZLWK 6FKHGXOLQJ QVWDOODWLRQ DQG 6HWXS XLGH ARMED READY PANIC OFF AWAY STAY MAX TEST BYPASS INSTANT CODE CHIME READY 1 2 3 6 5 4 8 9 7 0 ALARM CHECK FIRE AWAY STAY INSTA...

Page 2: ......

Page 3: ...ry and Panic Devices to Zones 1 9 3 6 Installing RPM Devices 3 9 Wireless Zone Expansion 3 11 Installing Output Devices 3 14 Installing the Ground Start Module 3 16 Installing a Remote Keyswitch 3 16...

Page 4: ...12 Up About Programming 6 14 Temporary Schedules 6 15 User Scheduling Menu Mode 6 16 SECTION 7 Downloading Primer 7 1 General Information 7 1 Unattended Download 7 2 Getting On Line with a Control Pan...

Page 5: ...Alarm A 1 UL611 UL1610 Central Station Burglary Alarm A 2 California State Fire Marshal CSFM and UL Residential Fire Battery Backup Requirements A 2 APPENDIX B Summary of System Commands B 1 APPENDIX...

Page 6: ...204 Relay Module 3 15 Figure 3 21 4204CF Relay Module 3 15 Figure 3 22 Wiring the FSA Module 3 15 Figure 3 23 Ground Start Module Connections 3 16 Figure 3 24 Remote Keyswitch Wiring 3 17 Figure 3 25...

Page 7: ...ties This symbol indicates a critical note that could seriously affect the operation of the system or could cause damage to the system Please read each warning carefully This symbol also denotes warni...

Page 8: ...viii...

Page 9: ...ADEMCO PassPoint system via the VISTA Gateway Module or a VistaKey module via the polling loop UL The access control function is not Listed for use with the VISTA 128B PLUS Control Panel in a UL inst...

Page 10: ...ng Can arm the system with zones faulted Vent Zone These zones are automatically bypassed and can be programmed to automatically unbypass when the zone restores Can arm with entry exit and interior ty...

Page 11: ...gle door access control module The system can support up to 250 access cards Supports ADEMCO PassPoint system via one VISTA Gateway Module VGM for a fully integrated access control system Can store ac...

Page 12: ...ach macro is a series of keypad commands of up to 32 keystrokes using the A B C and D keys by partition Provides cross zone capability which helps prevent false alarms by preventing a zone from going...

Page 13: ...o Partition 9 if Master keypad operation is desired See Master Keypad Setup and Operation later in this section Zones Each zone must be assigned to one partition The zones assigned to a partition will...

Page 14: ...at follows explanation The Common Lobby feature employs logic for automatic arming and disarming of the common lobby Two programming fields determine the way the common lobby will react relative to th...

Page 15: ...current status of the other partition when the user takes action Sequence 1 Office 1 Office 2 Lobby Action User 1 Disarms Armed Disarms User 2 Disarmed Disarms No Change User 1 Arms Disarmed No chang...

Page 16: ...ow another partition that is programmed to arm or disarm the lobby The lobby must be armed separately after arming all affecting partitions first Auto Arming Disarming If scheduling is used to automat...

Page 17: ...some partitions are ready Press 0 or 9 to return to the master partition Otherwise if no keys are pressed for 2 minutes the system automatically returns to the master partition The sounder on a Maste...

Page 18: ...Device Programming of its host VISTA 128B PLUS How to Use Panel Linking Panel Linking can be used in any of three different modes Single Partition Single Panel displays status of a partition on a remo...

Page 19: ...ress 1 to attempt to disarm all partitions Press 2 to attempt to arm AWAY all partitions Press 3 to attempt to arm STAY all partitions Press 4 to attempt to arm MAXIMUM all partitions Press 7 to attem...

Page 20: ...STANT all partitions Press 0 to exit mode After a few seconds the keypad displays the status of the original partition of the original panel for the keypad Also this mode will end in approximately 120...

Page 21: ...p for universal commercial cabinet To install the lock perform the following steps Step Action 1 Insert the key into the lock Position the lock in the hole making certain that the latch will make cont...

Page 22: ...Premises listing Mount a shock sensor such as Sentrol No 5402 to the control s backbox Follow the manufacturer s instructions for proper sensor mounting This sensor also must be wired to a hardwire z...

Page 23: ...wire gauge determined in step 1 4 Connect the keypad s to terminals 6 7 8 and 9 on the control board as shown in Figure 3 4 The length of all wire runs combined regardless of the wire gauge must not...

Page 24: ...e total current drawn from the auxiliary power polling loop and alarm output combined must not exceed 750mA For Household Burglary installations the total current drawn from the alarm output must not...

Page 25: ...ES NONPOLARIZED BURGLARY INDICATING DEVICES POLARIZED FIRE INDICATING DEVICE POLARIZING DIODES MUST MOUNT AT INDICATING DEVICE BELL BELL HORN non_polar_devices Figure 3 7 Wiring Nonpolarized Burglary...

Page 26: ...ervoltage protection in accordance with UL1459 as specified in UL985 UL1023 Reporting Formats The system supports the following formats ADEMCO Low Speed 3 1 4 1 4 2 Sescoa Radionics 3 1 4 1 4 2 ADEMCO...

Page 27: ...ast detector in the loop across the zone 1 terminals The EOL resistor must be connected across the loop wires at the last detector 2k EOLR ZONE 1 SMOKE 2 WIRE SMOKE DETECTOR 10 11 Figure 3 10 2 Wire S...

Page 28: ...ERED RELAY OPENS WHEN POWER IS LOST 2k EOLR For all above controls 4 wire smoke detectors may only be used on Zone 1 Figure 3 12 Wiring 4 Wire Smoke Detectors to a 333PRM The 333PRM reverses polarity...

Page 29: ...ices on the polling loop cannot total more than 128mA unless the system uses a 4297 Polling Loop Extender Module Devices that can be programmed via either DIP switches or the built in unique serial nu...

Page 30: ...oop see Figure 3 16 No individual wire run may exceed the lengths shown in the following table Maximum Polling Loop Wire Runs Wire Gauge Max Length 22 gauge 650 feet 20 gauge 950 feet 18 gauge 1500 fe...

Page 31: ...t 4297 modules in series Extension Loop 1 Extension Loop 2 Extension Loop 8 Up to 8 modules may be connected in parallel Extension loops will be electrically isolated if blue jumper on each 4297 is le...

Page 32: ...enabled in the system s Device Programming in the 93 Menu Mode To install the 5881 RF receiver perform the following steps Step Action 1 Mount the receiver following the advisories stated previously...

Page 33: ...red to as loops or inputs Each loop must be assigned a different zone number For button type transmitters wireless keys such as the 5804 and 5804BD you must assign a unique zone number to each individ...

Page 34: ...F 5890 PIR Detector RF Installing Output Devices The VISTA 128B PLUS supports up to 96 outputs to activate and de activate as desired Each device must be programmed as to how to act ACTION when to act...

Page 35: ...les in any combination can be supported The FSA module will not operate until the device address you have set the DIP switches for is enabled in the control s Device Programming in the 93 Menu Mode To...

Page 36: ...e line The wire that reads 50VDC is the RING side 2 Connect the 675 Ground Start Module to the panel s J7 connector trigger output 1 to auxiliary power and to the RING side of the telephone line as sh...

Page 37: ...gger a low current relay and wire the power for the smoke detectors through the relay s contacts NOTE The output is normally high 12VDC and goes low when the User Code Off is entered at the keypad To...

Page 38: ...door or attempt to attach it to the PC board To mount and wire the Panel Link Module refer to Figure 3 26 and perform the following steps Step Action 1 Remove all power from the control panel before...

Page 39: ...WIRING FROM C COM TO 7720 IN CONDUIT 2 CONNECT RADIO FAULT OUTPUT TO C COM EOLR SUPERVISED ZONE ZONE 2 8 ONLY USE 2K EOLR 3 SEE UL INSTALLATION REQUIREMENTS ON A LATER PAGE TO DETERMINE WHEN 659EN US...

Page 40: ...s sent to both the Primary Phone No and LRR Additional LRR reporting options are defined by selecting categories of events for each subscriber ID in fields 58 and 59 The reporting categories are Alarm...

Page 41: ...nd can be programmed to send the information to up to 8 different paging services In addition the module can direct the reports to a parallel or serial printer NOTE The APM is only required for alphan...

Page 42: ...Part Number K5350 Wiring the Alpha Pager Module The Alpha Pager Module connects via the 4142TR cable to the J8 connector on the VISTA 128B PLUS To wire the Alpha Pager Module refer to Figure 3 30 and...

Page 43: ...ept assigning the access point zone number 1 15 which is set via a user friendly 16 position rotary switch The addition and removal of VistaKey modules from the system is easily accomplished via the V...

Page 44: ...ROTECTION ASSOC BATTERYMARCH PARK QUINCY MA 02269 PRINTED INFORMATION DESCRIBING PROPER MAINTENANCE EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT TO TB1 11 OR 12 12 VDC...

Page 45: ...4100SM To connect a serial printer using the 4100SM refer to Figure 3 33 and perform the following steps Step Action 1 Connect terminal 23 on the control panel to terminal 3 on the 4100SM Step Action...

Page 46: ...ses phones and any answering machines The VIP module will not operate until the device address 04 is enabled in the control s Device Programming in 93 Menu Mode Do not mount the VIP Module on the cabi...

Page 47: ...3 34 4285 4286 VIP Module Connections Installing TeleSmart The TeleSmart system provides a voice interface for an ADEMCO security system It has the following features 4 unique mailboxes for storing me...

Page 48: ...170mA 130mA 6 7 Set the keypad address tamper option and playback volume setting by pressing and holding the 1 and 3 keys at the same time for 3 seconds then follows the prompts You must press these...

Page 49: ...ll send a Listen in to Follow If you are also using a 4285 4286 VIP Module be sure to follow Figure 3 42 when making connections To install the Eagle 1250 AAV module to the control perform the followi...

Page 50: ...TIONS FOR CONNECTIONS TO AUDIO SPEAKERS AND MICROPHONE EAGLE 1250 6 7 16 17 27 26 28 29 30 ZONE 5 J7 DIP Switch 1 2 3 4 5 6 ON CONTROL EARTH GROUND RED R GREEN T GREY R BROWN T INCOMING PHONE LINE RJ3...

Page 51: ...ATTERY CHARGING VOLTAGE 13 7 VDC NOTE WHEN POWERING UP THE PANEL PLUG THE TRANSFORMER IN BEFORE CONNECTING THE BATTERY BATTERY TABS PRIMARY POWER Supplied by a transformer which is rated at 16 5VAC 40...

Page 52: ...used This module is powered from the panel s auxiliary power and provides a separate polling loop output which can support an additional 128mA load Note that the total number of points connected to th...

Page 53: ...type These batteries require a different charging voltage than is supplied by the panel UL Household Fire or Combination Household Fire Burglary installations require the use of a backup battery that...

Page 54: ...arge mercantile cabinet only 14AH Yuasa NP7 12 Connect two in parallel 17 2AH Yuasa NPG18 12 Fits in large mercantile cabinet only 7 Connect the battery referring to Figure 3 43 The standby battery is...

Page 55: ...d Programming Mode In the Data Field Program Mode you may access any field simply by entering either or the field number To write or change information in a field press the field number 03 To read the...

Page 56: ...le a phone number the keypad displays the last entry and waits To proceed enter the next data field you wish to program Programming Partition Specific Data Fields To program partition specific data fi...

Page 57: ...aracteristics for addressable devices including keypads RF receivers 5881 output relay modules 4204 4204CF FSA FSA 8 FSA 24 4285 4286 VIP Module Panel Link Module VA8201 ECP long range radio 7845C and...

Page 58: ...ed 5 Audio Alarm Verification if used 7 Keyswitch if used 8 Latching Type Glassbreak Detectors if used 1 9 Traditional Hardwired Zones 9 RS232 Input if used 1 128 5800 Series Wireless Devices 10 128 P...

Page 59: ...04 00 040 10 00 076 01 00 112 07 00 005 05 00 041 11 00 077 02 00 113 08 00 006 06 00 042 12 00 078 03 00 114 09 00 007 07 00 043 13 00 079 04 00 115 10 00 008 08 00 044 14 00 080 05 00 116 11 00 009...

Page 60: ...rom the keypad Type 05 Trouble by Day Alarm by Night Provides an instant alarm if the zone is faulted and the system is armed in the AWAY STAY INSTANT or MAXIMUM mode During the disarmed state day the...

Page 61: ...one Expansion section for more information Zone Input Type Definitions Each zone must be assigned an input type which defines the where the system will look for status of the zone RF receiver polling...

Page 62: ...th Device Type 10 2 If you want to supervise the PLM program zone 8xx with response type 05 where xx the module s address If you want the zone to report to the central station make sure the report cod...

Page 63: ...is enabled in the PassPoint ACS See the PassPoint ACS documentation for a detailed explanation Programming the VISTA Gateway Module See the PassPoint ACS instructions to program the VISTA Gateway Modu...

Page 64: ...ect the output type ECP 1 4204 4204CF or 2 X 10 See Output Programming in the Programming Guide for a detailed explanation Using the VISTA 128B PLUS for Stand Alone Access Control The VISTA 128B PLUS...

Page 65: ...le Random Timers For Partitions 1 8 0 disable 1 enable If enabled the activation time of the window is randomized up to 30 minutes and is initialized by either of two methods User Code 41 Initiates th...

Page 66: ...witch LEDs Openings closing report as user 0 if enabled in field 40 16 Confirmation of Arming Ding partition specific 0 disable 1 enable If enabled produces second external alarm sounding ding at the...

Page 67: ...is desired enter a test code in Report Code Programming in 93 Menu Mode Set first test report time in field 83 Maximum Test report interval is 0024 for UL installations 28 Power Up in Previous State 0...

Page 68: ...ID Number Make entries as 2 digit numbers as follows 00 0 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 A 11 B 12 C 13 D 14 E 15 F Enter eight digits NOTE This field is applicable only if downloadin...

Page 69: ...one ring followed by nothing does not answer the first call but readies itself to pick up on the first ring of the next incoming call that is received within 30 seconds i e the downloader calling agai...

Page 70: ...rimary phone number field 33 downloader phone number field 35 Or you can go into the Unattended Program Mode from normal operating mode by entering User Code 8 9 56 Dynamic Signaling Delay Enter 00 15...

Page 71: ...elay if any for burglary alarm communications Must be 0 for UL installations 89 Restore Report Timing 0 instant 1 after bell timeout 2 when system is disarmed Select the time when restore reports are...

Page 72: ...arm the system before exit error occurs If the user does not re enter the premises and disarm the system the system bypasses the faulted entry exit and or interior zone s The rest of the system is arm...

Page 73: ...sed If a relay is programmed to activate on a fault of one of the zones the relay activates without the other zone being faulted If a relay is programmed to activate on either an alarm or trouble both...

Page 74: ...ction Must be 1 for UL 1 30 RF Receiver Supervision Check in Interval Enter 02 15 times 2 hours 4 30 hours 00 disable receiver supervision Select the check in monitoring interval for the RF receiver s...

Page 75: ...g partition specific 0 disable 1 enable If enabled the system produces slow beeping from the keypads during exit delay and reverts to rapid beeping during the last 10 seconds of the exit delay 1 46 Au...

Page 76: ...able 1 enable This field has five entries as follows Alarm Check Bypass Open Close System If enabled the system logs those types of events into the event log NOTE Events are also logged into the PassP...

Page 77: ...uto arming of the system 2 07 Auto Disarm Delay partition specific 00 no delay 01 14 times 4 minutes 04 56 delay 15 no auto disarming This is the time between the end of the disarming window and the s...

Page 78: ...s on the J7 radio triggers to the LRR The LRR uses these pulses to determine that its connection to the control is still intact Must be 1 for UL installations 2 22 Display Fire Alarms of Other Partiti...

Page 79: ...enable This field has six entries as follows Alarm Trouble Bypass Open Close System Test If enabled the system sends a signal to the pager 2 40 Pager 2 Phone Number Enter 0 9 11 for 12 for 13 for a 2...

Page 80: ...able 1 enable This field has six entries as follows Alarm Trouble Bypass Open Close System Test If enabled the system sends a signal to the pager 2 54 Pager 4 Phone Number Enter 0 9 11 for 12 for 13 f...

Page 81: ...enable This field has six entries as follows Alarm Trouble Bypass Open Close System Test If enabled the system sends a signal to the pager 2 68 Pager 6 Phone Number Enter 0 9 11 for 12 for 13 for a 2...

Page 82: ...able 1 enable This field has six entries as follows Alarm Trouble Bypass Open Close System Test If enabled the system sends a signal to the pager 2 82 Pager 8 Phone Number Enter 0 9 11 for 12 for 13 f...

Page 83: ...rements up to 56 minutes in partition specific program field 2 05 At the expiration of this delay the Auto Arm Warning will start Auto Arm Warning The Auto Arm Warning causes the keypad sounder to war...

Page 84: ...be made to perform an action only once e g turn on the porch light this Wednesday at 8 00 PM The system also provides up to 20 programmable timers available to the end user for the purpose of activat...

Page 85: ...h the store is closed Employees can arm and disarm the system when programmed within the open and close time windows without causing a report to be sent to the central station reporting by exception f...

Page 86: ...s before the closing window begins Missed Opening Closing type reports are programmed in the Report Code programming section The Exception Reporting option must be set for these to be sent Closing Win...

Page 87: ...Enter 0 to skip a section and display the next menu option PROMPT EXPLANATION Time Window 1 YES 0 NO 0 Upon entering Schedule Menu Mode this prompt appears Enter 1 to program time windows Refer to Ti...

Page 88: ...00 00AM If you entered a time window number the cursor is now positioned on the tens of hours digit of the start of window entry Enter the desired start of window hour and press The cursor moves to th...

Page 89: ...or the window number is displayed Press the key to accept the entry Tue P1 OP WIND 00 00 00 00 00 The keypad now prompts for Tuesday s open close schedule Follow the procedure for Monday s prompts Whe...

Page 90: ...ocedure for each holiday to be programmed Quit 1 YES 0 NO 0 Enter 0 at the Quit prompt to return to the main menu choices and continue programming Enter 1 to quit Scheduling Menu Mode Time Driven Even...

Page 91: ...ulted zns Partition s 25 Arm INSTANT Partition s 26 Arm MAXIMUM Partition s The auto arm warning field 2 06 applies when using Time Driven events to auto arm Temporary schedules do not override an aut...

Page 92: ...Code 41 This will randomize up to 30 minutes the activation time of all devices programmed for randomization assigned to the partition the sequence is entered in Enter the sequence again to turn off t...

Page 93: ...e right appears Enter the zone list number that contains the zones to be bypassed or unbypassed Press to accept entry The Time Window prompt appears 01 ZONE LIST ENTER 01 15 01 42 Enable Access Window...

Page 94: ...effect only for the duration of the window 04 Trigger at both the start and the end of the window Example coffee break buzzer 05 Random trigger up to 30 minutes after the start of the window 06 Rando...

Page 95: ...access schedule for the displayed day As the number is keyed in the actual time that has been stored for the window is displayed Press to continue MON A1 Window 2 00 00 00 00 00 Enter the second time...

Page 96: ...rsor moves to the minutes position Press the to move the cursor backwards Enter the minutes of the hour 00 59 Press to accept entry The cursor moves to the AM PM position Press to accept the current s...

Page 97: ...ess to accept entry 01 Arm AWAY Stop 1 YES 0 NO 0 Enter 1 YES if arming AWAY or MAXIMUM completely satisfies the Up About condition A new window starts upon disarming or arming STAY or INSTANT provide...

Page 98: ...0 00AM 00 00AM Repeat the procedure described above for all days of the week When all the windows for all the days have been completed the system prompts for which days of the schedule are to be activ...

Page 99: ...TIME 11 45 PM The cursor positioned on the tens of hours digit of the OFF time Enter the desired hour Press to move to the minutes field The minutes are entered in the same manner The AM PM indicatio...

Page 100: ...VISTA 128B PLUS Installation and Setup Guide 6 18...

Page 101: ...the control against compromise while it is being accessed from a remote location 1 Security code handshake The subscriber s account number as well as an 8 digit ID number known only to the office mus...

Page 102: ...e key to accept the phone number and exit Press the key to exit without changing any data The system displays the Quit menu prompt Press 1 to exit the Installer Unattended Program Mode or 0 to continu...

Page 103: ...uccessful link is established The system is now on line with the computer Alarms and Trouble responses and reports are disabled during actual uploading or downloading sessions If you are on line but n...

Page 104: ...ownloading is meant as a tool for the installer during the installation process The connections between the control and the 4100SM are different than those shown in the 4100SM Installation Instruction...

Page 105: ...e week is automatically calculated based on the date entered Time and date entries are made by simply entering the appropriate hour minute month day and year Press to move the cursor to the right of t...

Page 106: ...VISTA 128B PLUS Installation and Setup Guide 8 2...

Page 107: ...tain authority levels restrict disarming bypassing or the assigning of other user codes These restrictions are noted in the descriptions below Use the View Capabilities keypad function to view the par...

Page 108: ...ing modifications within the system based on the user code authority levels Master Codes and all lower level codes can be used interchangeably when performing system functions within a partition a sys...

Page 109: ...n unused number Also notice that no access is allowed for this user into Partitions 3 8 Attempts to access these partitions would be denied automatically Adding a Master Manager or Operator Code Durin...

Page 110: ...ser number authority level open close and global arm options that were programmed for each partition to which the user was granted access For example XMT USER DATA 1 YES 0 NO If the user number is fro...

Page 111: ...onfirm that you want to delete this user Press 0 NO or 1 YES If you answered yes that user s code is removed from all partitions to which it was assigned and all authorization levels and other informa...

Page 112: ...VISTA 128B PLUS Installation and Setup Guide 9 6...

Page 113: ...e conducted on a weekly basis When this test is first entered the system activates the alarm output for 3 seconds The system sends a Start of Walk Test message to the central station The keypad displa...

Page 114: ...m 2 Fault each wireless zone causing each device to transmit As the system receives a signal from each of the transmitters the zone number of that transmitter disappears from the display 3 Enter Insta...

Page 115: ...the telephone communication portion of your system LO BAT This indicates that a low battery condition exists in the wireless transmitter displayed Pressing any key silences the audible warning sound S...

Page 116: ...PLEASE before you call Technical Support be sure you READ THE INSTRUCTIONS Check all wiring connections Determine that the power supply and or backup battery are supplying proper voltages Verify your...

Page 117: ...sensors may not be used If 4190WH RPMs are used set field 24 to 0 to enable tamper detection Attach a door tamper switch supplied to the VISTA 128B PLUS cabinet backbox For safe and vault installatio...

Page 118: ...service except use the 7920SE in place of the 7720 California State Fire Marshal CSFM and UL Residential Fire Battery Backup Requirements The California State Fire Marshal and UL have regulations that...

Page 119: ...e FCC rules On the front cover of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipment If requested this inf...

Page 120: ...the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5 AVIS L tiquette d Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme a...

Page 121: ...ller or Master Only Wireless System Commands House ID Sniffer Mode Code 2 Installer Only Transmitter ID Test Code 3 Installer Only Go No Go Test Code 5 Test Key Partition GOTO User Code Partition Numb...

Page 122: ...ode 0 Request to Enter Exit User Code 73 Request to Enter Exit at Access Point User Code 74 Access Point Number Change Access Point State User Code 75 Access Point State Perform a Test of the VistaKey...

Page 123: ...750 mA aux load using 7 AH battery Circuit Protectors PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wirin...

Page 124: ...VISTA 128B PLUS Installation and Setup Guide C 2...

Page 125: ...f RPM Supervision 383 RPM Sensor Tamper 384 RF Transmitter Low Battery 389 Detector Self Test Failed 401 O C by User 403 Power Up Armed Auto Arm 406 Cancel by User Code Definition 407 Remote Arm Disar...

Page 126: ...M SHUT System Shutdown BYPASS Bypass SELF TEST Self test TEST ENTRY Manual Test Entry TEST EXIT Manual Test Exit Alpha Event Description LOG 50 FULL Event Log 50 Full LOG 90 FULL Event Log 90 Full LOG...

Page 127: ...et ACPT RLY Access Point Relay Supervision Fail SELF MOD Module Self Test Failure ACZN CHG Access Control Zone Change ACS PROG Access Control Program Entry ACS PRGX Access Control Program Exit THRT CH...

Page 128: ...VISTA 128B PLUS Installation and Setup Guide D 4...

Page 129: ...2 EXPRESS C 1 ADEMCO 4146 3 16 ADEMCO 685 receiver 3 6 ADEMCO 685 Receiver 3 29 Ademco AB12 3 1 ADEMCO Contact ID 3 6 ADEMCO CONTACT ID C 1 ADEMCO HIGH SPEED C 1 ADEMCO Low Speed 3 6 ADEMCO LOW SPEED...

Page 130: ...ress 9 1 Duress Codes Level 6 9 2 Duress Reporting 9 2 Dynamic Signaling Delay 3 20 5 6 Dynamic Signaling Priority 3 20 5 6 E Early Power Detect 3 21 Earth Ground 3 31 ECP Wire Run 3 18 Enable 5800 RF...

Page 131: ...ess 9 4 Multi Panel View Mode 2 8 Multi Partition Multi Panel Mode 2 7 Multiple Alarms 5 3 Multiple Partition Access 9 3 N No Alarm Response Type 23 4 7 Non UL Installations 3 4 Normally Closed or EOL...

Page 132: ...ate 5 12 Printer Configurations 3 25 Printer Type 5 12 Priority of Displays for Panel Linking 2 8 Program Modes 4 1 Programming Commands B 1 PROGRAMMING COMMANDS 4 1 Programming Entry Errors 4 2 Progr...

Page 133: ...pes 3 13 Transmitter Supervision 3 13 Trouble by Day Alarm by Night Type 05 4 6 Trouble Conditions 10 3 Trouble Messages 10 3 Turning the System Over to the User 10 4 U UL Installation Requirements A...

Page 134: ...ification 5 12 Zone 804 3 26 Zone Defaults 4 5 Zone Index 4 4 Zone Input Type Definitions 4 7 Zone Number Designations 4 4 ZONE PROG vii 4 3 Zone Response Type Definitions 4 6 Zone Type Restores for Z...

Page 135: ...y cannot detect motion or intrusion that takes place behind walls ceilings floors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material...

Page 136: ...E FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY W...

Page 137: ...jumper to disable supervision of alarm sounder output Leave jumper intact to supervise output See Installation and Setup Guide for Programming and Wiring Instructions Zone 9 may be used for RS232 inp...

Page 138: ...l K4968 11 00 165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION...

Reviews: