N6752V9 2/03
REMOTE KEYPADS
6128, 6137, 6137R, 6138, 6139, & 6139R
,167$//$7,21*8,'(
KEYPAD FEATURES
6128
Fixed-Word
Keypad
6137/6137R
Fixed-Word
Keypad
6138
1-Line Alpha
Keypad
6139/6139R
2-Line Alpha Keypad
Backlit Display
No
Yes (see note
below)
Yes (see note
below)
Yes (see note below)
Dedicated Panic Keys
No
Yes
Yes
Yes
Flush Mount Option
No
No
Yes
Yes
All the above keypads have backlit keys, are keypad addressable, have a Red ARMED indicator and a Green READY indicator.
ADEMCO CONTROLS
W
W
W
W
VIA16*/4110XM* / 4110DL*
Yes
Yes, 6137
No
No
VIA30P†*/ VIA30PSE†*
VISTA 10SE†*/VISTA 20SE†*
Yes
Yes, 6137
Yes
Yes, 6139
4120XM†*
Yes
Yes, 6137
No
Yes, 6139
4140XMP */VISTA 40†**
Yes
Yes, 6137
No
Yes, 6139
VISTA-50 P†**/VISTA-50 UL†** /
VISTA-128B†**
Yes
Yes, 6137
No
Yes, 6139
5110XM†*/5120XM†*
No
Yes, 6137 or
6137R***
No
Yes, 6139 or 6139R***
5140XM†**/VISTA-32FB†**/ VISTA-
100†**/VISTA 128FB†**
No
No
No
Yes, 6139 or 6139R***
† A 2-Line alpha-numeric display keypad must be used to program these controls.
*
Use non-addressable mode with these controls (set to address 31).
**
Use addressable mode (addresses 00–30).
***
Keypad color subject to approval of local authority having jurisdiction.
Note: Permanent display backlighting is an option on some controls; see the control's instructions.
GENERAL INFORMATION
The 6128, 6137, 6137R, 6138, 6139, and 6139R Remote Keypads are
keypad addressable (no DIP switches), and are intended for use
with the controls listed in the table above. They can be set for the
non-addressable operation (address 31) if required by the control
with which they are used.
Note: The 6137R and 6139R have red bezels instead of gray.
Otherwise, they are exactly the same as the 6137 and 6139,
respectively.
The 6128 and 6137 are fixed-word keypads that provide a two-digit
display for zone identification, and a set of predesignated English
language prompts (e.g., ALARM, AWAY, STAY, CHECK, etc.) for
indicating the system's status.
The 6138 is a one-line alpha keypad that displays a 2-line message
one line at a time. To display the second line of information, press
the [#] key. Press the [#] key again to return to the first line of
information. The display automatically returns to the first line of
information if no key is pressed for three seconds.
Note: After pressing the [#] key to view the second line or return to
the first line, wait at least three seconds before entering a control
panel command (e.g., arm the system).
The 6139 is a two-line alpha keypad equipped with a programmable
2-line, 32-character (16 characters per line) English language
display for complete zone identification (if descriptors are
programmed), plus system status.
The keys on the keypads are located behind a decorative door, and
are continuously backlit for convenience. The inside of the
decorative door has space for a zone ID label (supplied) on which
the installer can write descriptions of each zone for handy user
reference.
All keypads allow panic alarm activation (if enabled in control
programming). For the 6128, panic alarms are activated by
pressing key pairs [1] & [
✱
]
, [
✱
]
& [#], and [3] & [#].
The 6137/6137R, 6138, and 6139/6139R are equipped with
dedicated single keys for panic activation — keys A, B, and C (the D
key is not used as panic), which are equivalent to the [1] & [
✱
],
[
✱
] & [#], and [3] & [#] keys, respectively.
Single panic keys (A, B, and C) must be held down for at least
2 seconds to activate an alarm.
A set of adhesive-backed labels with some typical panic symbols
(i.e., fire, police, personal emergency, etc.) is provided. These labels
can be placed on or next to the keys to identify each key's function
for the end user (as determined by the control panel's capability
and programming; see the control's instructions).
READY
ARMED
PANIC
READY
1
2
3
6
5
4
8
9
7
0
*
#
INSTANT
CODE
CHIME
MAX
TEST
BYPASS
OFF
AWAY
STAY
6139-006-V0
A
B
C
D
Remove
case back
by pushing
down the
2 "snaps"
along the
keypad's
top edge
and pulling
the case
apart.
Figure 1. 6139 Keypad (Shown for Reference)
WIRING AND INSTALLATION
The keypads can be surface mounted directly to a wall, or to a
single- or double-gang electrical box. For flush mounting the 6138
and 6139/6139R to drywall, use the optional 6139TRK Flush Mount
Kit (6128 & 6137/6137R cannot be flush mounted).