Summary of Contents for 4130XM

Page 1: ...VISTA SERIES 4130XM 5130XM 4140XMP USER S MANUAL N4811V4 2 92 ...

Page 2: ...lUMCREDlTREQUEST 23 QUICK GUIDE TO SYSTEM Functions 25 EMERGENCYPHONE NUMBERS 26 GLOSSARY 27 FCCSTATEMENT 29 THE LIMITATIONS OF lSAMRM SYSTEM 3O About This Manual 1 This manual is a step by step guide that will acquaint you with the system s features and benefits It defines the components and their functions describes their operation and acquaints you with normal and emergency procedures The Secur...

Page 3: ... station placed smoke or combustion detectors designed to provide early warning in case of fire I 1 41 I v v STANDARD THE ALPHA DISPLAY CONSOLE features a multifunction cklit 12 key digital keypad and uses a 2 line 32 character fully programmable alphanumeric Liquid Crystal Display LCD which displays the nature and location of all occurrences in friendly English Console display backlighting is pro...

Page 4: ...not be assianed HIGH SECURITY FEATURE The system can be programmed to require a 6 digit code for arming and disarming The 6 digit code consists of the 2 digit user number plus a 4 digit code Ask your installer if thi feature has been programmed USER 22 SPECIAL FEATURE Babysitter Code option The system can be programmed so that user 22 can disarm the system on y if the system was previously armed b...

Page 5: ...windows while the system is disarmed Refer to the other sections of this manual for procedures for using these features ENTRY EXIT DELAYS stLh HtLP FEAflfRE Your system is programmed by the installer with preset time delays during which the system must be disarmed upon entering or an alarm will occur This feature allows you to leave and reenter through the entry delay door without setting off the ...

Page 6: ...m Displays previously bypassed protection zones 7 CHIME KEY Turns on off the CHIME mode When on any entry through a delay or perimeter zone while the system is disarmed will cause a tone to sound at the Console s 6 8 KEY Permits ARMING of the system without use of a security code Quick Arm if programmed to do so 9 KEYS O 9 Used to enter your individual security access code s 10 CODE KEY Allows the...

Page 7: ... is activated BAT Low battery condition in a Radio Transmitter if used LARM Appears when an intrusion has been detected and the system is armed also appears during a Fire alarm Accompanied by the protection zone ID in alarm CHECK Appears when a malfunction is discovered in the system at any time or if a fault is detected in a FIRE zone at any time or in a DAY NGHT burglary zone during a disarmed p...

Page 8: ...nsole can also display the zone descriptors that a programmed in your system by pressing the READY key and holding down for at least 5 seconds The abbreviated instructions for the READY key will appear first followed by the descriptors programmed for your system Displaying all descricdors is useful when vou need when all protection zones have to kn ow the zone num6er of a been either closed or byp...

Page 9: ... system as usual automatically bypass al I open faulted zones without having to enter each opened zone numtrm 1 Enter the security code 2 Press the BYPASS key 3 Press the key Wait for all bypassed zones to be sequentially dispfayed then continue with step 4 of normal procedure DISPLAYING BYPASSED ZONES For determining what zones have been previously bypassed 1 Enter security code and press BYPASS ...

Page 10: ...guarding doors and windows with entry delay on Late arrivals can enter through the entry delay zone door and disarm the system within the entry delay period without causing an alarm See your installer for actual delay times set for your system Alarms will occur instantly when any exterior protection point is violated except the entry delay zone door which will activate an alarm if the system is no...

Page 11: ...e entry delay zone dmr and disarm the system within the entry delay period without causing an alarm See your instaEar for actual detay times set for your system Atarrns will occur instantly when any prot do npoint intafioror exterior is viotated except the entry delay zone door if AWAY key pmssetLWhii WiU emalSImif thesystem isnotd edwithinthe entry delay period MAXIMUM KEY RESULT Arms all perimet...

Page 12: ...the displayed NOTIFICATION section for protection zone and remedy the information which will enable you to fault close windows etc If the distinguish between FIRE and fault cannot be remedied notify BURGIARY alarm sounds the alarm agency 11 DURESS CODE WHEN FORCED TO DISARM ARM Enter the first three or 5 digits of the security code Increase the final digit by one and then press OFF or AWAY etc if ...

Page 13: ...ME MODE ON message will appear for about two seconds then disappear To display this message again to determine whether chime mode is on or off simply press and hold down the CHIME key for 5 seconds To turn Chime Mode off enter the security code and press the CHIME 9 key again The CHIME MODE OFF message will appear for about two seconds then disappear Isllzlfi ISARMED I i5515 h l READY TOARM ma m 0...

Page 14: ...displayed aszone96 RESULT If programmed for silent emergency by your installer and the system is connected to a central alarrr monitoring station the control will sen a silent alarm signal to the central station but there will be no audible alarms or visual displays If programmed for audible emergency by your installer a loud steady alarm will sound at your console and at any external sounders tha...

Page 15: ...ch protected door and window in turn Each action should produce three beeps from the Console and the identification of each protection point should appear on the dispfay 6 7 8 9 Walk in front of any interior motion detectors if used Listen for three beeps as the detector senses movement The identif tion of the detector shoukt appear when it is activated Follow the manufacturer s instructions to te...

Page 16: ...inute beeping at the Console indicates that a low battery condition exists in the wireless transmitter displayed CALL FOR SERVICE IMMEDIATELY POWER FAILURE If the POWER indicator is off operating power for the system has stopped and is inoperative CALL FOR SERVICE IMMEDIATELY If the POWER indicator is on but the message AC LOSS is displayed the Console is operating on battery power only If only so...

Page 17: ...and notify your local Fire Department immediately 4 If no flames or smoke are apparent investigate the cause of the alarm The zone descriptor of the zone s in an alarm condition will be displayed at the Console Note Approval of the panel s burglar alarm functions does not fall within the California State Fire Marshal s area of jurisdiction SILENCING A FIRE ALARM 1 Silence the alarm by entering you...

Page 18: ...he immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition it is recommended that the householder consider the use of heat or smoke detectors in the living room dining room bedroom s kitchen hallway s attic furnace room utility and storage rooms basements and attached garages Llvwc ao...

Page 19: ...ed to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room ExAMFiES m U iEELl FLoo 4 5 6 7 8 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you bscape Try the door If the door is hot check your alternate escape route If the door is cool open it cautiousl...

Page 20: ... are displayed One beep is heard for each zone displayed Subsequently the following is displayed DISARMED BYPASS Ready to Arm Opened Zone identltications will appear LO BAT displayed with description of transmitter ARMED AWAY or ARMED MAXIMUM is displayed Red ARMED indicator is lit a ARMED STAY ZONE BYPASSED or ARMED INSTANT ZONE BYPASSED is display ed Red ARMED indicator is lit b CHIME displayed ...

Page 21: ...RRM is disdaved protection zone in alarm is also dl played a Only REfl OV is displayed b NOT REflOY is displayed open protection zone number is displayed c The bypassed protection zone numbers are displayed One beep for each number displayed BVP13SS displayed Opened Zone identtf cationsWIII appear BAT displayed with ID number of transmitter 13illfl f and possiblv lNSTfl NT are displayed a ST13Yand...

Page 22: ...visory problems call for serv immediately ID number 95 96 or 99 represent Panic alarm codes assgned by the installer ID number 97 represents a system supervisory problem call for service immediately For your convenience a chart has been provided which may be used to record the specific protection points that have been assigned to each zone in your system Your installer will assist you in rewding t...

Page 23: ... Locale Sounding Device m Police Dept n Fire Dept m Central Station u Name end Address C POWERED BY A C With Rechargeable Power Supply D TESTING Quarterly Monthly Weekly Other E SMOKE DETECTOR LOCATIONS Furnace Room Ktchen 1 Bedrooms 1 Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door RearDcmr All Exterior Doors Ist Floor Windows All windows...

Page 24: ...IComplete the reverse side of this form detach from manual and forward to your homeowner s insurance carrier for possible premium credit 24 ...

Page 25: ...ass Enter code Press BYPASS 6 Press 1 Chime Mode Enter code Press CHIME 9 Test Mode Enter code Press TEST 5 View Messages Press and hold 0 for at least 5 seconds Self Help Press and hold any function key for at least 5 seconds rogra mmed by installer Arms system in mode selected Disarms svstem and silences alarms Bypassed zones are unprotected and will not cause an alarm if violated Bypasses all f...

Page 26: ...mm Dxxr FvTtd3m Emr fry SERVICING INFORMATION Your local authorized service representative is the person best qualified Ito service your alarm system Arranging some kind of regular program with him is advisable Your local service representative is Y _26 ...

Page 27: ...he system and perform other functions which were previously described in this manual ZONE A specific area of protection BYPASS To disarm a specific area of burglary protection while leaving other areas operational DELAY ZONE An area of protection containing doors most frequently used to enter or exit typically a front door back door or door from the garage into the building The delay zone allows s...

Page 28: ...e certifie que Ie matr iel es conforme certaines normes de protection d exploitation et de 54curit6 des r eaux de Wcommun ications Le minis tt re n assure toutefols pas que Ie mat 5nel onctionnera A la satisfaction de Milissteur Want installer ce mak iel I utifisateur doit s assurer qu il est parmis de Ie raccorder aux installations de entreprise locale de t61 ommunication Le mat riel dolt bgaleme...

Page 29: ...ferent branch circuits f necessary the user should consult the dealer or an experienced adioltelevision technician for additional suggestions Fhe user or installer may find the following booklet prepared by the Federal communications Commission helpful Interference Handbook Fhis booklet is available from the U S Government Printing Office Washington IC 20402 Stock No 004 000 00450 7 he user shall ...

Page 30: ...nstalled and positioned Smoke detectors may not sense fires that start where smoke cannot reach the detectors such as in chimneys in walls or roofs or on the other side of closed doors Smoke detectors also may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or basement fire Moreover smoke detectors have sensing limitation...

Page 31: ...m responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not respond appropriately This equipment like other electrical devices is subject to component failure Even though this equipment is designed to last as long as 10 years the electronic components could fail a...

Page 32: ...GES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Seller do...