Scale installation and operation 

Your ADE portion scale with induction charging is a quality product. 
It is ideal for use wherever dusty or harsh working conditions prevail, including professional 
commercial  kitchens,  bakeries,  butcher  shops,  etc.  With  the  ProSeal  technology,  the 
annoyance about dirt, dust, splashing water and corrosion is a thing of the past.  
Thanks  to  the  induction  charging  used,  the  scale  has  no  interfaces  at  all  in  order  to  avoid 
corrosion or contamination of connections. From the polymer membrane to the foot thread, it 
offers  a  completely  sealed  housing  with  IP65  dust  and  splashing  water  protection  that  has 
been intelligently designed and moulded to meet the highest demands, with no inaccessible 
grooves,  gaps  or  acute  angles  at  all.  In  addition,  the  weighing  surface  and  the  supporting 
substation can be disassembled in no time thanks to a practical quick-release fastener. Ideal 
for all-round easy cleaning that leaves no residues behind. 
Backlight  and  automatic  power-off,  as  well  as  the  display  of  different  units  can  be  set  or 
disabled. 
To  achieve  precise  results,  please  read  the  user  guide  carefully  and  follow  the  instructions 
contained therein. 

Inspecting the contents of the box 

  Portion scale 

  Load cross, silicone mat and weighing plate 

  Quick-release fastener for the load cross 

  Induction charger 

  User manual incl. declaration of conformity 

Safety information 

 

The induction charger generates an electromagnetic field. This can pose 
a threat to persons with pacemakers or other implants!

 

 

Never attempt to charge the scale with/on an induction hob/cooker. This 
is NOT technically feasible and can also cause destruction of the scale.

 

Mains and battery connection of the scale 

Power is supplied either by means of the rechargeable batteries already installed in the device 
or  through mains operation using the included AC adapter (230 V AC). The printed voltage 
level must comply with the local voltage. 

 

The rechargeable batteries are already installed in the scale housing. 

When charging the device for the first time, use the included AC adapter. The charging 
time is approx. 12 hours during initial charging. 

When fully charged, the scale has an operating time of up to 120 hours. 

Summary of Contents for PWI30

Page 1: ...H Co KG Hammer Steindamm 27 29 22089 Hamburg Germany 49 0 40 432776 0 Fax 49 0 40 432776 10 E mail info ade germany de Portion scale PWI30 with induction charging PWI30 190920 Rev005 UM en IMPORTANT READ CAREFULLY BEFORE USE PLEASE KEEP FOR FUTURE REFERENCE ...

Page 2: ...harging 5 Assembling and levelling the scale 6 Using the scale 6 Switching on the scale 6 Determining weight 6 Zeroing the scale 6 Tare function 6 Setting the unit of weight 7 Switching off the scale 7 Error messages 7 Parameter settings 7 Backlight 8 Selecting the unit 8 Automatic power off in battery mode 9 Digit interval d 9 Zero offset 9 Cleaning 10 Safety information 10 Storage and transport ...

Page 3: ...PWI30 190920 Rev005 UM en 2 Overview display 1 Spirit level 2 LCD display 3 Buttons 4 Weighing plate 5 Housing 6 Foot 7 Induction charging base 8 Induction charger 9 Charging adapter ...

Page 4: ...rn on and off To toggle between the units of weight Display symbols EEEEEE Overload a beep sounds at the same time immediately remove the object from the weighing platform Indication that a fixed weight value has been stored which will be subtracted at each subsequent weighing process TARE symbol Indication that the scale is reset to zero Indication that the achieved weight value is stable Battery...

Page 5: ... power off as well as the display of different units can be set or disabled To achieve precise results please read the user guide carefully and follow the instructions contained therein Inspecting the contents of the box Portion scale Load cross silicone mat and weighing plate Quick release fastener for the load cross Induction charger User manual incl declaration of conformity Safety information ...

Page 6: ...ments symbols are opposite each other The charging function is available only if the distance between the transmission and reception elements is sufficiently small It is therefore necessary to ensure that the induction charger is properly positioned in the induction charging base LED display for induction charging Slide the induction charger into the induction charging base and connect the chargin...

Page 7: ... three seconds The display will show ADE for two seconds and will then automatically switch to weighing mode 0 000 is shown on the display If this is not the case press the button As a result measurement inaccuracies will be compensated after turning on the scale and will be reset to zero before the actual weighing process The display now shows 0 000 and the figure indicates the zero position show...

Page 8: ... back to the kg unit The selected unit is shown as on the display Switching off the scale To manually turn off the scale press and hold down the button for four seconds in weighing mode As soon as a beep sounds release the button and the scale will turn off Error messages Overload EEEEE display The scale overload 9d is signalled by the EEEEE display The overload must be eliminated immediately to p...

Page 9: ... unit Use this parameter setting to disable the units of weight the display of which is not required t9 Enable On or disable Off the display of kg as the unit of weight 9 Enable On or disable Off the display of g as the unit of weight lb Enable On or disable Off the display of lb as the unit of weight oZ Enable On or disable Off the display of oz as the unit of weight Press the button to save the ...

Page 10: ...e displayed digit interval It is recommended to leave this setting unchanged and use the button to switch immediately to the next parameter setting If it is necessary to adjust the division there are the following setting options d 1 1 g division d 2 2 g division d 5 5 g division d 10 10 g division d 20 20 g division Press the button to save the selected setting and switch automatically to the nex...

Page 11: ...ranes on the underside that prevent the formation of condensate inside the scale To ensure protection against mechanical damage the membranes are provided with two bleed screw caps that must also be cleaned if they are soiled During assembly make sure that the membranes and seals are inserted correctly Safety information Safe operation is no longer guaranteed If the AC adapter or the power cord sh...

Page 12: ...s etc are excluded This warranty does not cover external normal signs of wear and tear or damages caused by accident or misuse The warranty will not apply for devices that have been opened by unauthorised persons In addition the operation of the scale with damaged or missing membranes is not allowed and will void the warranty The statutory rights of the customer are not affected by this agreement ...

Page 13: ...afe Quick release fastener for disassembly of the weighing surface Working conditions Ambient temperature 10 C 50 C Relative humidity 1 80 Functions Weighing taring units of weight kg g lb oz User friendly 2 button operation Unit conversion 1 kg 1000 g 1 kg 2 206 lb 1 kg 35 27 oz Power supply 230 V AC mains and battery operation interface free Induction charging power adapter 5 V DC 1 A high perfo...

Page 14: ...tive 2014 30 EU regarding electromagnetic compatibility Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in the currently valid versions This declaration will lose its validity if any modification is made to the scale without our consent Hamburg January 2019 ADE Germany GmbH Co KG Hammer Steindamm 27 29 D 22089 Hamburg Manufacturer ADE Germany GmbH Co KG Hammer Steindamm 27 29 D 22089 Ha...

Page 15: ...PWI30 190920 Rev005 UM en 14 ...

Page 16: ...15 PWI30 190920 Rev005 UM en Distributor ...

Reviews: