ON / TARE 

To switch the scale on/off and to zero it. 
For taring a desired weight value. 

UNIT 

To switch between the weight units (kg, lb). 

MEM 

For storing and recalling measured values. 

 

Positioning and commissioning of the scale 

Insert batteries 

Open the battery compartment underneath the scale and insert batteries 4x LR6 / AA 1.5V (not 
included in delivery) 

Make sure to insert batteries respecting the indicated polarity (+/-). Close the battery 
compartment and control the safe latching. 

Positioning of the scale 

Place the scale on a level surface. 
Make sure all four flexible feet embedded on the bottom side of the scale have direct contact 
to the surface. Minor unevenness is levelled by the flexibility of the feet. 
 

Make sure the scale is not bouncing but has a firm stand. 
This is imperative to secure the safety of the baby and a necessary condition to achieve 
a correct and reliable weight result. 

Commissioning of the scale 

The  scale  can  be  operated  on  either  mains  or  batteries.  Subject  to  proper  insertment  of 
batteries you may switch on the scale immediately by pressing the ON / TARE key. 
 
For use on mains the scale has to be connected to the mains adapter included.  
The  connecting  plug  is  situated  on  the  backside  of  the  scale.  Make  sure  to  only  use  the 
delivered mains adapter. 
Before  connection  of  mains  adapter  please  check  the  voltage  parameter  imprinted  on  the 
mains adapter corresponds to the local voltage. If this is not the case DO NOT connect the 
adapter to the scale! 
 
Connect the mains adapter to the local power supply. 
 
 

 

Summary of Contents for M112600

Page 1: ...Operating Manual International Range Electronic Baby Scale M112600 Electronic Baby Scale M112600 M112600 210511 Rev004 UM e ...

Page 2: ...batteries 3 Positioning of the scale 3 Commissioning of the scale 3 Use of the scale 4 Some remarks before weighing 4 Tare Function Tare 4 Select Weighing Unit 4 Memory Function 5 Maintenance and Care 5 Cleaning advice 5 Warning signals 5 Storage and Transport 5 Waste disposal 5 Warranty Liability 6 CE Declaration of Conformity 7 Technical Data 8 ...

Page 3: ...against accidental dropping Do not let the infant child jump around on the scale This product is not a toy and should not be used as one When not in use store out of reach of children Before use make sure that the mains voltage and type of current indicated on the rating plate match the mains voltage and type of current at the place of use Make sure that the mains cable is not a potential trip haz...

Page 4: ...e Minor unevenness is levelled by the flexibility of the feet Make sure the scale is not bouncing but has a firm stand This is imperative to secure the safety of the baby and a necessary condition to achieve a correct and reliable weight result Commissioning of the scale The scale can be operated on either mains or batteries Subject to proper insertment of batteries you may switch on the scale imm...

Page 5: ...inking once it reached a standstill In case the baby remains on the tray for a while the blinking weight indication remains on the display for another 5 minutes before the scale shuts off automatically Taking the baby off the tray while the weight result is still blinking the display will come automatically back to the zero indication 0 000 before switching off automatically after 5 minutes 7 For ...

Page 6: ...rage To recognize this the display shows Err when pressing the MEM key Maintenance and Care Cleaning advice For cleaning just use a damp cloth or common disinfection products Do NOT use any aggressive cleaning fluids Take care no water is penetrating the scale This might cause severe damage to the electronic part and would set the scale out of order Warning signals If display shows o Ld too much w...

Page 7: ...uitable or improper storage The cost of transport will be borne by the customer should the equipment be located anywhere other than the customer s premises In the event of transport damage claims under warranty can be accepted subject to using the complete original packaging and the equipment secured the way it was packed and secured originally All the packaging should therefore be retained Any wa...

Page 8: ...bH Neuer Hoeltigbaum 15 22143 Hamburg Germany 49 40 432 776 0 49 40 432 776 10 info ade germany de www ade germany de Declaration of conformity by the manufacturer These scales have been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30 EU Low Voltage Directive 2014 35 EU RoHS Directive 2011 65 ...

Page 9: ... of the scale WxDxH 600 x 385 x 85 mm Tray BxTxH 600 x 280 x 40 mm Large LCD Display 30 mm Max Capacity 20 kg Graduation d 5 g Changeable weight units kg lb Tare and multi tare function Memory function Battery operation 4 x LR6 AA 1 5V Net Weight ca 2 6 kg ...

Page 10: ...9 M112600 210511 Rev004 UM e ...

Page 11: ...M112600 210511 Rev004 UM e 10 ...

Page 12: ...11 M112600 210511 Rev004 UM e Dealer ...

Reviews: