ADE GW400 Series Operating Manual Download Page 5

GW400-210408-Rev004-UM-en 

 

5.  Scope of delivery 

Check the  delivery  for  completeness  as soon  as  you receive  the  scale. Carefully  unpack  the 
scale and accessories and remove all packaging materials. 

The following items are included in the delivery: 

-  Compact scale 

-  Power supply 

-  Operating manual 

-  Declaration of conformity 

-  Optional: 6 V 4 Ah rechargeable battery (inserted in the scale) 

 

 

For calibrated scales: Check the identity of the scale serial numbers and the 
declaration of conformity. This is a mandatory requirement to use the scale in 
legal metrology! 

6.  Getting started with the scale 

1.  Carefully unpack the scale and accessories and remove all packaging materials. 

2.  Remove the transportation lock, if any, at the bottom of the scale. The transportation lock 

is provided with the label shown below: 

 

 

 

 

If  you  do  not  remove  the  transportation  lock,  your  scale  can  show 
incorrect weighing results! 

3.  Place the scale on a level, stable surface. Do not place the scale on a shaky or vibrating 

table as this will cause distortion of measurement results. 

4.  Connect one end of the power supply to the power connector on the bottom of the scale 

and the other end to the local power supply. 

 

In this case, before connecting the supplied mains adapter to the scale, 
make sure that the voltage on the nameplate matches the local power 
supply. 

 

After the warm-up time (15 minutes), the scale is ready for use. 

The  warm-up  time  applies  to  every  disconnection  from  the  mains 
(except battery mode). 

5.  Align the scale using the support feet. Make sure that the air bubble of the spirit level is 

centred in the black frame. 

 

Check the horizontal position of the scale 
after every change of location! 

 

6.  Switch  on  the  scale.  When  switching  on  the  scale,  the  weighing  platform  must  be 

unloaded. The scale runs through a test programme and acknowledges the end of the 
switch-on routine with a sound signal. 

 

If  the  weighing  platform  is  loaded  during  the  switch-on  process,  the 
scale  is  not  properly  ready  for  operation.  Switch  off  the  scale  and 
repeat the switch-on process. 

Transport 
Transport 

Transports 

Wägen 

Weighing 

Pèsent 

Transportsicherung 
Transportation lock 

Séurités de transport 

Summary of Contents for GW400 Series

Page 1: ...OPERATING MANUAL Electronic compact scales Compact scale GW400 series GW400 210408 Rev004 UM en...

Page 2: ...6 Key names and functions 6 Display symbols 7 Battery status indicator 7 8 Using the scale 7 Preliminary note 7 Switching the scale on and off 7 Zeroing 8 Taring 8 9 Backlight and parameter settings...

Page 3: ...ne When reselling the scale the operating manual must also be supplied Target group This operating manual is intended for personnel who are responsible for setting up operating care and maintenance of...

Page 4: ...4 Intended use Your ADE scale is a quality product and was manufactured for use as a non automatic scale The scale is intended for determining the weight of goods and for a variety of other weighing...

Page 5: ...vibrating table as this will cause distortion of measurement results 4 Connect one end of the power supply to the power connector on the bottom of the scale and the other end to the local power supply...

Page 6: ...y connector 3 Spirit level 8 On Off switch 4 Keypad 9 Battery compartment cover 5 Battery indicator Key names and functions Symbol Description Function ZERO Zeroing key If this key is pressed the scal...

Page 7: ...to prevent irreparable damage to the load cell Switching the scale on and off Switching on the scale Remove all weights from the weighing surface Switch on the scale The On Off switch is located belo...

Page 8: ...ce the tare weight will be displayed as a negative value Pressing the key after unloading the weighing surface clears the tare weight If the display is not stable the arrow will not light up on the st...

Page 9: ...n press the key The menu can be exited by selecting the bACk parameter and pressing the key Caution On calibrated scales various functions such as CAL and GrA are locked A change leads to the loss of...

Page 10: ...cannot be eliminated or other error messages occur please contact your service partner Faults Fault Cause Measure The display shows nothing The scale has switched off automatically Switch on the scale...

Page 11: ...f the scale to avoid damage Disposal Waste electrical equipment does not belong in household waste Devices with this marking may not be disposed of as residual waste but must be recycled Remove if pos...

Page 12: ...authorised personnel can perform recalibration On the CE mark you can find the year of initial calibration next to the notified body 0122 Recalibration must be carried out when one or more security m...

Page 13: ...LED backlight display backlight can be disabled Casing Stable plastic housing Keypad Easy care membrane keypad Functions Weighing taring Automatic zeroing Overload indicator Battery level indicator a...

Page 14: ...NAWI directive 2014 31 EU EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in their respectively applicable versions This declaration will lose its validity if any...

Page 15: ...GW400 210408 Rev004 UM en 15...

Page 16: ...16 GW400 210408 Rev004 UM en Distributor...

Reviews: