ADE ESW10 Series Operating Manual Download Page 7

ESW10-200206-Rev007-UM-en 

 

 
 

Display symbols 

Symbol

 

Meaning 

 

 

Display for stable weight measurement. 

“GROSS” 

Display for gross weight. 

“TARE” 

Display for activated tare function. 

“ZERO” 

Display for zeroing. 

 

Low battery indicator. 

Battery status indicator “Charging” 

green 

Battery fully charged. 

yellow 

Battery is charging. 

red 

Battery almost discharged. 

9. 

Operation during weighing processes 

Zeroing the scale 

The scale is equipped with an automatic zero compensation for minimal deviations or residues 
on the platform. 

The 

 key can be pressed to reset if a low weight is displayed even though the platform is 

empty. 

You can press the 

 key to reset at any time in weighing or counting mode. However, this 

is normally only necessary if the weighing platform is empty. 

When the zero point is reached, the display shows “ZERO”. 

Taring 

Place  the  container  to  be  tared  on  the  scale  pan  and  press  the 

 key.  The  previously 

displayed  weight  of  the  container  is  saved  and  the  display  shows  “ZERO”.  The  display  also 
shows “TARE”. 

After removing the container, its weight is displayed as a minus value. 

If an item to be weighed is added to the container, the scale automatically subtracts the tare 
value of the container from the total weight and displays the result as a net value. 

The scale can be tared several times by pressing the 

 key if additional items to be weighed 

are added. Again only the value of the added items to be weighed is displayed. 

If  the  container  is  removed  from  the  platform,  the  weight  of  the  container  (and  possibly  the 
already tared weighed goods) is displayed as a negative number. 

Pressing  the 

 key  again  returns  the  scale  to  the  actual  zero  position  and  the  “ZERO” 

symbol appears on the display. 

Summary of Contents for ESW10 Series

Page 1: ...W10 200206 Rev007 UM de ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 40 432 776 0 Fax 49 40 432 776 10 Email info ade germany de OPERATING MANUAL READ BEFORE USE PLEASE KEEP...

Page 2: ...splay elements 5 Operating elements 5 Display symbols 6 Battery status indicator Charging 6 9 Operation during weighing processes 6 Zeroing the scale 6 Taring 6 Counting programme 7 Weight control 7 A...

Page 3: ...who operate the scale must have read and understood this operating manual before using it for the first time 3 Safety instructions It is essential that you read understand and follow all instructions...

Page 4: ...ease contact authorised customer support 4 Intended use Your ADE ESW10 floor scale is a high quality product and was manufactured for use as a non automatic scale The scale is ideal as a precise fast...

Page 5: ...e is exactly in the centre of the spirit level 10 First connect the power supply to the corresponding plug on the rear of the display device and only then connect to the mains Make sure that the suppl...

Page 6: ...mode Taring is indicated by the TARE symbol on the display In counting mode it is used to select the reference piece count SAMPLE Piece count key Switches from weighing mode to counting mode In count...

Page 7: ...is empty When the zero point is reached the display shows ZERO Taring Place the container to be tared on the scale pan and press the key The previously displayed weight of the container is saved and...

Page 8: ...hen it is reached or exceeded The memory can be preset for a maximum and a minimum value Preliminary remarks Enter the control target weight range Set the control target weight range by saving both a...

Page 9: ...The scale can be set so that additional weighings can be done manually by pressing the key The additional weighing function is only possible during the weighing process This function is not available...

Page 10: ...ts Pressing the key increases the digits Confirm the set value by pressing the key Pressing the key cancels the process and exits the menu without saving Example When the display shows F0 H L press th...

Page 11: ...ight EL on Backlight activated EL Au Backlight automatic EL off Backlight disabled EL Au bEEP Sets the beep function Control mode 2 Control mode 3 No beep F5 Prt Setting the RS232 interface for printi...

Page 12: ...nit of weight No 1 This number indicates that a new value is saved in the memory at any time TOTAL 12 340 kg The total value stored If two blank lines If The total weight piece weight and piece count...

Page 13: ...to the mains Weight display is unstable Draughts or air movements Close the window Choose a different location Vibrations Avoid vibrations Choose a different location Electromagnetic fields static ch...

Page 14: ...mal display range Remove the overloading weight from the scale and make sure that the weighing platform is correctly positioned If the values remain unchanged this indicates that the measuring cell or...

Page 15: ...will not apply for devices that have been opened by unauthorised persons The statutory rights of the customer are not affected by this agreement in any way The dealer from whom the scale was purchase...

Page 16: ...2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in their respectively applicable versions This declaration will lose its validity if any modification is made to the scale withou...

Page 17: ...ESW10 200206 Rev007 UM en 16...

Page 18: ...17 ESW10 200206 Rev007 UM en Distributor...

Reviews: