Warranty 

ADE will repair or replace this product if evidence is provided that it has failed within 1 year from 
the date of sale (proof of purchase is required) due to lack of workmanship or defective material. 
All moving parts, such as batteries, cables, etc. are excluded. 

The use of accessories other than those approved by ADE, especially batteries, will void the 
warranty. 

This warranty does not cover external normal wear and tear or damage caused by accident or 
misuse. The warranty will not apply for devices that have been opened by unauthorised persons. 
The statutory rights of the customer are not affected by this agreement in any way. 

The dealer from whom the scale was purchased is responsible for complaints, customer service 
and spare parts. 

14.  Technical data 

Model 

ESW10 

Maximum load 

150 kg 

Division 

10 g 

Scale dimensions (WxDxH) 

420 x 670 x 950 mm 

Dimensions of the weighing platform 

420 x 520 mm 

Weighing platform material 

Stainless steel 

Interface 

RS-232 output 

Stabilisation time 

Typically 1 second 

Ambient temperature 

0°C – +40°C 

Display 

6-digit LCD display with 24 mm high digits 

Supply / power supply 

External AC adapter, 9 V, 800 mA 

Battery 

6 V/DC / 4 Ah internal rechargeable battery 

 

 

 

Summary of Contents for ESW10 Series

Page 1: ...W10 200206 Rev007 UM de ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 40 432 776 0 Fax 49 40 432 776 10 Email info ade germany de OPERATING MANUAL READ BEFORE USE PLEASE KEEP...

Page 2: ...splay elements 5 Operating elements 5 Display symbols 6 Battery status indicator Charging 6 9 Operation during weighing processes 6 Zeroing the scale 6 Taring 6 Counting programme 7 Weight control 7 A...

Page 3: ...who operate the scale must have read and understood this operating manual before using it for the first time 3 Safety instructions It is essential that you read understand and follow all instructions...

Page 4: ...ease contact authorised customer support 4 Intended use Your ADE ESW10 floor scale is a high quality product and was manufactured for use as a non automatic scale The scale is ideal as a precise fast...

Page 5: ...e is exactly in the centre of the spirit level 10 First connect the power supply to the corresponding plug on the rear of the display device and only then connect to the mains Make sure that the suppl...

Page 6: ...mode Taring is indicated by the TARE symbol on the display In counting mode it is used to select the reference piece count SAMPLE Piece count key Switches from weighing mode to counting mode In count...

Page 7: ...is empty When the zero point is reached the display shows ZERO Taring Place the container to be tared on the scale pan and press the key The previously displayed weight of the container is saved and...

Page 8: ...hen it is reached or exceeded The memory can be preset for a maximum and a minimum value Preliminary remarks Enter the control target weight range Set the control target weight range by saving both a...

Page 9: ...The scale can be set so that additional weighings can be done manually by pressing the key The additional weighing function is only possible during the weighing process This function is not available...

Page 10: ...ts Pressing the key increases the digits Confirm the set value by pressing the key Pressing the key cancels the process and exits the menu without saving Example When the display shows F0 H L press th...

Page 11: ...ight EL on Backlight activated EL Au Backlight automatic EL off Backlight disabled EL Au bEEP Sets the beep function Control mode 2 Control mode 3 No beep F5 Prt Setting the RS232 interface for printi...

Page 12: ...nit of weight No 1 This number indicates that a new value is saved in the memory at any time TOTAL 12 340 kg The total value stored If two blank lines If The total weight piece weight and piece count...

Page 13: ...to the mains Weight display is unstable Draughts or air movements Close the window Choose a different location Vibrations Avoid vibrations Choose a different location Electromagnetic fields static ch...

Page 14: ...mal display range Remove the overloading weight from the scale and make sure that the weighing platform is correctly positioned If the values remain unchanged this indicates that the measuring cell or...

Page 15: ...will not apply for devices that have been opened by unauthorised persons The statutory rights of the customer are not affected by this agreement in any way The dealer from whom the scale was purchase...

Page 16: ...2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in their respectively applicable versions This declaration will lose its validity if any modification is made to the scale withou...

Page 17: ...ESW10 200206 Rev007 UM en 16...

Page 18: ...17 ESW10 200206 Rev007 UM en Distributor...

Reviews: