AddSecure IRIS-4 50 Quick Installation And Maintenance Manual Download Page 6

IRIS-4 50

Quick Installation and
Maintenance Guide

6

7. SPECIFICATIONS

Transmission paths      Edge DS2220 / IRIS-4 50

Cellular 
  LTE (4G) Cat1 

B28A(700MHz), B20(800MHz), B8(900MHz)

  

 

B3(1800 MHz), B1(2100MHz), B7(2600MHz)

  UMTS (3G) 

 B8(900MHz), B3(1800MHz), B1(2100 MHz) 

  GPRS (2G)  

B8(900MHz), B3(1800MHz)

  Connection 

 SMA socket for antenna

  Fault detection 

Loss of registration with network, loss of connectivity to ISA/ARC

IP
  TCP ports (outbound)  53165 (Alarms and Polling)
  

 

51292 (Diagnostic and Reflashing)

  

 

10001  (Upload/Download)

Alarm transmission
  Interface to 

 ISA or IRIS Management Suite via

  Monitoring Center 

EN 50136-2 pass-through mode

  Dial capture interface 

Two-wire interface

  to alarm panel 
  Serial interface  

RS232 (basic TX/RX)

  to alarm panel 

  PIN Inputs interface 

Maximum input voltage range 0V to +28V DC

   

 

Input ‘low’ (alarm) threshold < 1V

  

 

Input ‘high’ (restore) threshold > 2V

  

 

Selectable internal pull-up 

  

 

impedance 10K to 3.3V supply

 Note:

Cabling must not exceed 3 meters

 Note:

Cabling must not exceed 3 meters

 Note:

Cabling must not exceed 3 meters

Summary of Contents for IRIS-4 50

Page 1: ...AIRBORNE DC MEDIUM Hurtigmanual Snabbguide IRIS 4 50 Quick Installation and Maintenance Guide...

Page 2: ...ting pads Adhesive mounting pad Cable tie wrap for mounting Signal strength default button USB micro connector Cable harness loom with color coded identification Cellular antenna connection Terminal A...

Page 3: ...nitoring centre IP address LED COLOUR DISPLAY REASON Terminal status green On steady No faults Flashing on 0 5s off 0 5s One or more fault present Cellular yellow On Cellular OK will flicker off for 0...

Page 4: ...is expected to be available Do not fix the antenna until after the terminal has been powered up and the cellular signal strength can be checked see section Connecting Power below 6 INSTALLATION 6 4 Co...

Page 5: ...can be configured using the IRIS Toolbox software application on a PC connected to the terminal with a USB cable Please use Toolbox software version 4 7 1 or later To reset to factory default setting...

Page 6: ...utbound 53165 Alarms and Polling 51292 Diagnostic and Reflashing 10001 Upload Download Alarm transmission Interface to ISA or IRIS Management Suite via Monitoring Center EN 50136 2 pass through mode D...

Page 7: ...um operating voltage 28V DC Maximum current rating 100mA DC Power supply Supply voltage 5 28 VDC Typical current 80mA 12VDC 40mA 24VDC Maximum current 1A 12VDC Recommended external PSU 12V DC 1A 12 Wa...

Page 8: ...have the following safety classifications Power Interface SELV for connection to a DC supply Inputs SELV for connection to alarm output pin CONFORMANCE European Directives The terminal complies with t...