![AddSecure IRIS-4 50 Quick Installation And Maintenance Manual Download Page 6](http://html1.mh-extra.com/html/addsecure/iris-4-50/iris-4-50_quick-installation-and-maintenance-manual_3047293006.webp)
IRIS-4 50
Quick Installation and
Maintenance Guide
6
7. SPECIFICATIONS
Transmission paths Edge DS2220 / IRIS-4 50
Cellular
LTE (4G) Cat1
B28A(700MHz), B20(800MHz), B8(900MHz)
B3(1800 MHz), B1(2100MHz), B7(2600MHz)
UMTS (3G)
B8(900MHz), B3(1800MHz), B1(2100 MHz)
GPRS (2G)
B8(900MHz), B3(1800MHz)
Connection
SMA socket for antenna
Fault detection
Loss of registration with network, loss of connectivity to ISA/ARC
IP
TCP ports (outbound) 53165 (Alarms and Polling)
51292 (Diagnostic and Reflashing)
10001 (Upload/Download)
Alarm transmission
Interface to
ISA or IRIS Management Suite via
Monitoring Center
EN 50136-2 pass-through mode
Dial capture interface
Two-wire interface
to alarm panel
Serial interface
RS232 (basic TX/RX)
to alarm panel
PIN Inputs interface
Maximum input voltage range 0V to +28V DC
Input ‘low’ (alarm) threshold < 1V
Input ‘high’ (restore) threshold > 2V
Selectable internal pull-up
impedance 10K to 3.3V supply
Note:
Cabling must not exceed 3 meters
Note:
Cabling must not exceed 3 meters
Note:
Cabling must not exceed 3 meters