3. PRODUCT FEATURES

FEATURES 

IRIS-4 50

Cellular network interface 2/3/4G 

1

eSIM  

1

Dial capture input 

1

Pin inputs 

2

Relay outputs 

2

Serial input (RS232) 

1

4. BEFORE YOU START

The terminal must have its cellular subscription activated, prior to installation, by going 
to 

www.addsecure.com/activate

, and using the Terminal Activation Code (TAC), which is 

found on the terminal and the packaging. Make sure that the monitoring centre (ARC) to 
which the terminal will send alarm signals is equipped with the appropriate IRIS Secure 
Apps receiving system.

The following information should be obtained from the Monitoring Centre. 
•  Terminal account number.
•  Monitoring centre IP address.

LED COLOUR 

DISPLAY 

REASON

Terminal status (green)

 

On, steady 

No faults.

 

Flashing, on 0.5s, off 0.5s 

One or more fault present.

Cellular (yellow)

 

On  

Cellular OK, will flicker off for 0.1s to    

 

 

shows poll to alarm receiver at ARC.

 

Flashing, 0.5s on. 0.5s off 

Polling failed or not configured.

 

Flashing, 0.1s on, 0.9s off 

Registered to cellular network, but

 

 

no IP connection.

 

Off 

Not registered to cellular network.

Panel (red)

 

On 

Panel interface OK.

 

Flashing, on 0.5s, off 0.5s 

Panel interface fault, either Dial Capture 

 

 

tamper, pin input tamper or no serial 

 

 

activity. Note each of these fault notifica-

 

 

tions are disabled by default. 

    All LEDs

  

Will flash together for a short period when the terminal has been defaulted.

     

 

Will blink together for a short period if the terminal is installing new

 

 

software which it has received.

5. LED INDICATIONS 

Summary of Contents for IRIS-4 50

Page 1: ...AIRBORNE DC MEDIUM Hurtigmanual Snabbguide IRIS 4 50 Quick Installation and Maintenance Guide...

Page 2: ...ting pads Adhesive mounting pad Cable tie wrap for mounting Signal strength default button USB micro connector Cable harness loom with color coded identification Cellular antenna connection Terminal A...

Page 3: ...nitoring centre IP address LED COLOUR DISPLAY REASON Terminal status green On steady No faults Flashing on 0 5s off 0 5s One or more fault present Cellular yellow On Cellular OK will flicker off for 0...

Page 4: ...is expected to be available Do not fix the antenna until after the terminal has been powered up and the cellular signal strength can be checked see section Connecting Power below 6 INSTALLATION 6 4 Co...

Page 5: ...can be configured using the IRIS Toolbox software application on a PC connected to the terminal with a USB cable Please use Toolbox software version 4 7 1 or later To reset to factory default setting...

Page 6: ...utbound 53165 Alarms and Polling 51292 Diagnostic and Reflashing 10001 Upload Download Alarm transmission Interface to ISA or IRIS Management Suite via Monitoring Center EN 50136 2 pass through mode D...

Page 7: ...um operating voltage 28V DC Maximum current rating 100mA DC Power supply Supply voltage 5 28 VDC Typical current 80mA 12VDC 40mA 24VDC Maximum current 1A 12VDC Recommended external PSU 12V DC 1A 12 Wa...

Page 8: ...have the following safety classifications Power Interface SELV for connection to a DC supply Inputs SELV for connection to alarm output pin CONFORMANCE European Directives The terminal complies with t...

Reviews: