specified by EU directive 2014/33 and the EN81 regulations. Before leaving 

the site, you should obtain confirmation from the ARC that all is working 

correctly. 

 

12

 

Specifications

 

Ethernet  

Standard  

10/100 Base T with auto-negotiation, up to 100m 

Connection  

RJ45 socket for CAT5 cabling  

IP addressing 

Dynamic (DHCP) or fixed 

Fault detection 

Loss of Ethernet synchronization 

Wi-Fi  

Standard 

IEEE 802.11 b/g/n 

Connection 

2.4GHz b/g/n with internal PCBA chip antenna  

Fault detection 

Loss of association/data  

2G/3G/4G  

Frequencies 

Penta band LTE (4G) 

 

800/900/1800 MHz  

 

2100/2600 MHz  

 

Dual band UMTS (3G)  

 

900/2100 MHz  

 

Dual band GSM (2G)  

 

900/1800 MHz  

Connection 

MMCX socket for antenna on PCBA. On VS5051 additional SMA 

socket on the outside of the enclosure. 

Fault detection 

Loss of registration with network 

IP  

TCP ports (outbound)  

53165 (Alarms and Polling), 51292 (Diagnostic and Reflashing),  

 

10001 (Upload/Download)  

Alarm Transmission Interfaces 

Interface to ARC  

Addsecure Connect  

Dial capture interface to voice 

panel 

Two-wire interface via terminal block.  

Serial interfaces 

RS485, TTL (max 3 metres), RS232 (max 3 metres) 

PIN Inputs interface 

Maximum input voltage range 0V to +28V DC (max 3 metres) 

 

Input “low” (alarm) threshold < 1V 

 

Input “high” (restore) threshold > 2V 

 

Internal pull-up impedance 10K to 3.3V supply 

Alarm protocols supported 

 

 

SIA (level 1 to 3) reference SIA DC-03-1990.01(R2003.10) 

 

Contact ID reference SIA DC-05-1999.09 

 

FF (Scancom) 

 

Robofon (Dial capture only) 

 

Telim (Dial capture only) 

 

CESA (Dial capture only) 

Panel protocols supported 

 

Section

 

Details

 

Summary of Contents for Edge VS5010

Page 1: ...PDK 13010 v 6 0 Edge VS5010 and VS5051 User manual Edge VS5010 and VS5051 User Manual...

Page 2: ...ackup batteries for VS5051 7 7 6 Connecting voice panels and alarm transmitters 7 7 7 Connecting the terminal 7 7 7 1 Power Outputs 7 7 8 Powering up the terminal 8 8 Configuring the terminal 8 8 1 Ch...

Page 3: ...1 AddSecure Connect AddSecure Connect is a cloud based platform that uses a secure private LINK network via the on board eSIM and does not require the installer to add a SIM card It provides secure a...

Page 4: ...u can analyse and setup an installation remotely over AddSecure Connect You can read more about AddSecure Connect on www addsecure com 4 Before you start Ensure that a subscription to AddSecure Connec...

Page 5: ...Light BT Not in use DC power in PNL Panel LED Expansion port PWR Power LED TTL serial port CEL Cellular LED Pin inputs 4 ETH Ethernet LED RS232 port SYS System LED Case Tamper input Cellular diversit...

Page 6: ...erminal in the enclosure using the fixing kits supplied 2 Connect cables from the alarm panels voice panels and alarm transmitters to the terminal PCBA to the appropriate connections see section 7 6 C...

Page 7: ...figuration Note Only use battery packs provided by AddSecure 7 6 Connecting voice panels and alarm transmitters All voice panels or alarm panels sited in elevators use the two wire Dial Capture port 2...

Page 8: ...contact AddSecure 8 Configuring the terminal The terminal does not need to be configured All the configuration and activation is done by AddSecure directly to the unit 8 1 Checking signal strength A g...

Page 9: ...Local connection Internet accessible Ethernet OK Polling OK data activity System No power System fault System OK 9 Configuration of the voice panels For details about the configuration of specific vo...

Page 10: ...s required by EU directive 2014 33 11 2 Maintaining data AddSecure keep the information about the location of the plant phone numbers and related information updated based on input from the owner or s...

Page 11: ...Connection MMCX socket for antenna on PCBA On VS5051 additional SMA socket on the outside of the enclosure Fault detection Loss of registration with network IP TCP ports outbound 53165 Alarms and Poll...

Page 12: ...tronic protection 2 2A polyfuse Number of switchable outputs 3 Voltage at which fault is reported 10V Voltage at which fault is restored 11V Power storage device Type 7 2V NiMH rechargeable batteries...

Page 13: ...output pin 14 Conformance The terminal complies with the following European Directives and standards 2014 53 EU Radio Equipment Directive 2002 96 EC WEEE 2011 65 EC ROHS No 1907 2006 REACH EN81 28 EN8...

Page 14: ...ht No part of this document may be reproduced or used except as authorized by contract or other written permission from AddSecure The copyright and foregoing restriction on reproduction and use extend...

Reviews: