background image

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)   

Phone: 408-453-6212 

Email: www.addonics.com/support/query/

Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

BZS –   Error buzzer function

EZ   –   Automatic rebuilding to spare drive (one of the drives on the raid is set as a  

 

spare). If EZ is ENABLED anda drive failure occurs, the spare will    

 

automatically act as a drive replacement and rebuilding will automatically  

 start.

M2  –   RAID mode 2

M1  –   RAID mode 1

M0  –   RAID mode 0

1. 

Error buzzer function is ENABLED (BZS) when dip switch is in OFF position

2. 

Auto-rebuilding to spare drive is DISABLED (EZ)

3. 

Individual drive mode is ENABLED (M0~M2)

Note: 

When the default factory RAID setting is used, independent drive configuration 

and optical drive are supported only when connecting to controllers with Silicon 

Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) 

compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.

LED Pin Header

J1 – Drive Activity LED

P5  –   Activity LED for eSATA host port lights up when it is connected to a           

 

SATA controller card.

P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is 

connected and blinks when there’s drive activity.

J3 – Error LED

P5  –   error LED for eSATA host port

P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5

J3 

  

 

    J1

Error LED    

 Activity LED

P5  P0  P1  P2  P3  P4

P5  P0  P1  P2  P3  P4

1      2      3      4      5

SW1

BZS  EZ    M2   M1   M0

OFF

OFF

OFF

OFF

OFF

Summary of Contents for ST55HPMXA

Page 1: ...o get your unit functioning properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 6212 Email http www addonics com suppo...

Page 2: ...the hard drives into the optional mounting brackets or slide in 5 25 devices into the tower Other types of enclosures like the 5SA disk array can also be mounted Mounting one 5SA disk array and anoth...

Page 3: ...de Raid Mode 1 2 3 4 5 Individual Drive Factory Default OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON ON OFF OFF ON OFF OFF OFF ON ON 0 1 and 10 3 5...

Page 4: ...ual drive mode is ENABLED M0 M2 Note When the default factory RAID setting is used independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Imag...

Page 5: ...he 5 port HPM XA using DIP switch Recommended to be used on operating system without JMicron HW RAID Manager support like Linux Mac Solaris Windows users can also use the procedure below Note Steps A...

Page 6: ...BLED EZ function is DISABLED 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 0 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Clone Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 1 RAID 10 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Large Mo...

Page 7: ...s connected to an eSATA host controller card on the RAID BIOS the raid array will display as Addonics H W RAID0 if setup as a RAID0 array k If booted into Windows in Disk Drives under Device Manager t...

Page 8: ...are For a 2 drive RAID1 with spare Drives connected to SATA ports 1 4 belong to the active RAID1 array and drive connected to port 5 is the spare B When will rebuild action start When the raid fails a...

Reviews: