background image

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)   

Phone: 408-453-6212 

Email: www.addonics.com/support/query/

Dip Switch Settings

Enable

ERR Buzzer

Function

Auto-

Rebuilding

to Spare

Drive

Port Multiplier Mode

Raid Mode

1               2 

   3                4               5

Individual Drive

(Factory Default)

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

ON

0

1 and 10

3

5

Clone

Large

RAID Setting Button

Dip Switch

eSATA Host Port (Port 5)

SATA Port 2

SATA Port 1

SATA Port 0

SATA Port 3

SATA Port 4

Drive activity LED Jumper Block (J1)
Error LED Jumper Block (J3)

Floppy

Power

Connector

Summary of Contents for ST55HPMXA

Page 1: ...o get your unit functioning properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 6212 Email http www addonics com suppo...

Page 2: ...the hard drives into the optional mounting brackets or slide in 5 25 devices into the tower Other types of enclosures like the 5SA disk array can also be mounted Mounting one 5SA disk array and anoth...

Page 3: ...de Raid Mode 1 2 3 4 5 Individual Drive Factory Default OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON ON OFF OFF ON OFF OFF OFF ON ON 0 1 and 10 3 5...

Page 4: ...ual drive mode is ENABLED M0 M2 Note When the default factory RAID setting is used independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Imag...

Page 5: ...he 5 port HPM XA using DIP switch Recommended to be used on operating system without JMicron HW RAID Manager support like Linux Mac Solaris Windows users can also use the procedure below Note Steps A...

Page 6: ...BLED EZ function is DISABLED 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 0 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Clone Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 1 RAID 10 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Large Mo...

Page 7: ...s connected to an eSATA host controller card on the RAID BIOS the raid array will display as Addonics H W RAID0 if setup as a RAID0 array k If booted into Windows in Disk Drives under Device Manager t...

Page 8: ...are For a 2 drive RAID1 with spare Drives connected to SATA ports 1 4 belong to the active RAID1 array and drive connected to port 5 is the spare B When will rebuild action start When the raid fails a...

Reviews: