Charging   

By specific power adaptor, charging time 6 hours 

Power consumption 

Maximum power 2W 

Environment 

Specification guaranteed temperature range: (10~30)

 

Working Temperature: (-10~50)

 

Storage temperature: (-20~70)

 

Humidity: 0% ~ 95% RH, non-condensing 

Maximum altitude: 3000m 

Warm-up Time 

After 10 minutes of power on, specifications can be reached 

Ports Protection Voltage 

50Vmax 

CE Certificate 

TUV  IEC61326, IEC61010 

Rohs

 

Compliance 

Rohs II Directive 2011/65/EU, EN50581:2012 

IP Protection Level 

IP67, 1 meter drop test 

Vibration 

5g for low and high frequency 

Impact 

8g 

Salt spray test 

48 hours 

Summary of Contents for 282

Page 1: ...282 Dual Channel Reference Thermometer Readout...

Page 2: ......

Page 3: ...ADT282 Dual Channel Reference Thermometer Readout User Manual Version 2204V01 Additel Corporation...

Page 4: ...s for the ADT282 Dual Channel Reference Thermometer Readout To ensure correct operation and safety please follow the instructions in this manual Additel Corporation reserves the right to change the co...

Page 5: ...Specifications of Signal Measurement Environment Temperature 20 10 1 year accuracy 9 1 3 3 RTD Measurement 10 1 3 4 TC Measurement 11 1 4 Basic Structure 16 1 5 Accessory 18 1 6 Power Supply 19 2 Dis...

Page 6: ...th 28 4 2 Power Management 28 4 2 1 Display Brightness 28 4 2 2 Battery Information 28 4 2 3 Auto Backlight Off 28 4 2 4 Auto Sleep 29 4 2 5 Auto power off 29 4 3 Service 29 4 3 1 Calibration 29 4 3 2...

Page 7: ...erature unit Converter 33 6 2 Thermal calculator 33 6 3 Sensor Library 33 6 4 Data Logger 33 6 4 1 Logger Management 34 6 4 2 The start of data logging 34 6 4 3 The operation of data logging 35 6 4 4...

Page 8: ...oltage applied between the terminals or between any terminal and the grounding cannot exceed the rated value Before using the product please check the appearance of the product to ensure there is no d...

Page 9: ...display and supports plug and play of intelligent temperature probe ADT282 has a sensor library with numerous temperature sensors it is an ideal substitute for standard primary mercury thermometer Wi...

Page 10: ...hnical Specifications Table 2 General technical Specifications Item Specification Display 5 0 inch 480 800TFT LCD capacitive screen Dimensions 16 97 x 4 13 x 2 04 177 mm x 105 mm x 52 mm Weight 1 5 lb...

Page 11: ...temperature 20 70 Humidity 0 95 RH non condensing Maximum altitude 3000m Warm up Time After 10 minutes of power on specifications can be reached Ports Protection Voltage 50Vmax CE Certificate TUV IEC6...

Page 12: ...nd cyclically measure RTD measuring rate 1 6S single channel 1 6S dual channel TC measuring rate 0 8S single channel 0 8S dual channel CHA CHB digital channel simultaneously measure RTD measurement 6...

Page 13: ...ions of signal measurement Environment Temperature 20 10 1 year accuracy Signal types Range Resolution Accuracy RTD 0 400 0 1m 0 5m 0 20 25ppm 20 400 TC 10 75 mV 0 1uV 50ppmRDG 2uV Internal CJC NA NA...

Page 14: ...nvironment temperature 20 10 RTD Types Temperature 1 Year Accuracy PT10 385 200 850 200 200 0 014 200 600 0 024 600 850 0 033 PT25 385 200 850 200 200 0 012 200 600 0 024 600 850 0 033 PT50 385 200 85...

Page 15: ...olerance of the RTD measurement excluding the accuracy of the probe 2 After connecting the probe the combined accuracy can be calculated directly after the RSS root sum square of the probe accuracy an...

Page 16: ...32 R 50 1768 50 0 0 54 0 56 0 200 0 38 0 41 200 1768 0 25 0 29 B 0 1820 200 300 1 01 1 02 300 500 0 66 0 68 500 800 0 41 0 44 800 1820 0 28 0 32 K 270 1372 250 200 0 48 0 50 200 100 0 15 0 21 100 600...

Page 17: ...0 26 0 30 200 100 0 10 0 18 100 700 0 06 0 16 700 1000 0 08 0 17 J 210 1200 210 100 0 13 0 20 100 700 0 06 0 16 700 1200 0 10 0 18 T 270 400 250 100 0 36 0 39 100 0 0 08 0 17 0 400 0 05 0 16 C 0 2315...

Page 18: ...0 31 2000 2315 0 42 0 45 G 0 2315 50 100 0 60 0 62 100 200 0 38 0 41 200 400 0 24 0 28 400 1500 0 16 0 22 1500 2315 0 32 0 35 L 200 900 200 100 0 07 0 17 100 400 0 06 0 16 400 900 0 07 0 17 U 200 600...

Page 19: ...ture standard determined by the maximum tolerance of the TC mV measurement excluding the accuracy of the probe 2 After connecting the probe the combined accuracy can be calculated directly after the R...

Page 20: ...1 4 Basic Structure Figure 1 Basic Structure...

Page 21: ...ch display and capacitive screen 2 Power button Switch on off 3 Lemo style port A Connect to external modules 4 Lemo style port B Connect to external modules 5 Adapter port Power supply 6 USB slave po...

Page 22: ...e for connecting users RTD 2 pcs 2 pcs USB cable TYPE A to C 1 pc Power adaptor 1 pc Smart Li battery 1 pc Hanging strap User manual English 1 pc Certificate electrical English 1 pc Optional Lemo port...

Page 23: ...r adaptor The power adapter quickly adapts to various countries power plugs Please do not put the product in fire or short circuit the battery Use only the power adaptor provided by Additel for chargi...

Page 24: ...Figure 3 1 Status bar includes time and date battery status lock screen status Bluetooth and message control center Note Click the status bar to enter the control center for quickly view and control m...

Page 25: ...control multi function items as shown in Figure 4 Figure 4 Control center Date and time of the system click to modify Battery level shows battery remaining plug the adaptor and change the charge mode...

Page 26: ...lick to lock the screen Icon means the screen is locked operate will be not allowed Go to the control center to unlock The bottom part of the control center is the signal of different channels orderly...

Page 27: ...l time and the current signal type information is displayed on the upper left Click the icon to switch the signal type Click the menu icon in the upper right corner to set the current channel in the p...

Page 28: ...function Note To prevent damaging the device do not try to force the mini TC plug into the wrong terminal since one terminal is wider than the other If there is a temperature difference between the de...

Page 29: ...e are 2 lemo style RTD measurement sockets on the top of the unit to connect the RTDs After connecting the RTD to the device click the type switch menu of the corresponding temperature channel and sel...

Page 30: ...measurement channel to select the filter menu item in the pop up menu and the filter setup interface will be displayed Table 10 Table 10 Filter Setup Subject Valid Value Description Enable Enable dis...

Page 31: ...ing range is 1 FS 3 1 7 Statistics Click the menu icon in the measurement channel and select the statistics menu in the pop up menu the maximum value Max minimum value Min and average value Avg of the...

Page 32: ...ing interface provides the enable and disable of the Bluetooth communication function and the query function of the Bluetooth device name and physical address 4 2 Power Management 4 2 1 Display Bright...

Page 33: ...to never then the auto sleep will be invalid 4 2 5 Auto power off If there is no button and communication command operation within the set time the backlight will be turned off and the automatic shut...

Page 34: ...ancel zeroing to cancel the zero data of the item 4 3 2 Maintenance A password is required to access to this function The factory default password is 123456 Maintenance records The maintenance informa...

Page 35: ...ce provides multi languages and the available languages can be selected through this menu After the language is selected the device needs to be rebooted to take effect 4 4 3 Date Time The date and tim...

Page 36: ...ly information including basic information version information and operating information Basic information including product model serial number and system version information Modules information incl...

Page 37: ...sor types which can easily convert between temperature and electrical signals for different sensors 6 3 Sensor Library In order to meet the needs of user custom sensor types the device provides a sens...

Page 38: ...lete the logging channels click on the added channel to enter the current channel detailed configuration interface and further set the channel s measurement items units filter and other information Fo...

Page 39: ...a logging operation area and record operation information display area 1 Data record curve display area The abscissa is the time which will be automatically adjusted according to the time of the loggi...

Page 40: ...rk theme The display area can only show up to two channels at the same time When the number of channels exceeds two you can switch to other channel display by sliding left and right 3 Record operation...

Page 41: ...the data When the data logging is completed or manually terminated the calibrator will automatically display the record save interface and the record name and operator information need to be entered...

Page 42: ...ial temperature module CH1 and CH2 represent two temperature measurement channels at the top of the device Real time data Real time differential temperature value Read only When the temperature differ...

Page 43: ...nabled and the CH1 and CH2 can measure the temperature users can perform the channel align By doing this the device will calculate and save the temperature difference between two channels and calculat...

Page 44: ......