Safety information

•  For use in dry, oil free indoor environments only.
•  Not suitable for use in hazardous or explosive environments or next to highly 

flammable materials.

•  Warning – the power adapter contains live parts.
•  No user serviceable parts are contained within the power adapter - do not 

dismantle.

•  Do not use the power adapter if the power adapter case becomes damaged, 

cracked or broken or if you suspect that it is not operating properly.

•  Replace the power adapter with a manufacturer approved type only. 
•  If you use a power extension cable, make sure the total ampere rating of the 

devices plugged into the extension cable do not exceed the cable’s ampere 
rating. Also, make sure that the total ampere rating of all the devices 
plugged into the wall outlet does not exceed the wall outlet’s ampere rating.

•  Do not attempt to service the CCS4-USB unit, the power adapter or the 

optional remote control yourself.

•  The power adapter can get warm in operation – do not situate it in an 

enclosed space without any ventilation. 

•  The CCS4-USB unit does not provide ground isolation and should not be 

used for any applications that require ground isolation or galvanic isolation.

•  When using the power adapter, use only with a grounded outlet. When 

using a backup power supply (UPS), power the computers, the monitors and 
the CCS4-USB from the same supply.

Warranty

Adder Technology Ltd warrants that this product shall be free from defects in 
workmanship and materials for a period of two years from the date of original 
purchase. If the product should fail to operate correctly in normal use during the 
warranty period, Adder will replace or repair it free of charge. No liability can be 
accepted for damage due to misuse or circumstances outside Adder’s control. 
Also Adder will not be responsible for any loss, damage or injury arising directly 
or indirectly from the use of this product. Adder’s total liability under the terms 
of this warranty shall in all circumstances be limited to the replacement value 
of this product. If any difficulty is experienced in the installation or use of this 
product that you are unable to resolve, please contact your supplier.

Summary of Contents for CCS4-USB

Page 1: ...CCS4 USB Four port keyboard and mouse switch Now with Free Flow switching technology...

Page 2: ...switching 12 Miscellaneous functions 12 OPTIONS port speed 12 Free Flow configuration 13 Installing the Free Flow configuration application 13 Configuring the Free Flow system 13 Optional Free Flow o...

Page 3: ...nity X50 and X USB to extend the distance between the user and the computers under control Switching between the systems connected to the CCS4 USB can be achieved in five different ways The innovative...

Page 4: ...se moment to switch from one screen system to the next The beauty of Free Flow is its simplicity of configuration and operation Once the initial configuration has taken place all monitoring and switch...

Page 5: ...of the necessary signals states and processes Therefore manufacturers have previously relied upon a fixed keyboard and mouse profile that is declared to each computer regardless of the actual connect...

Page 6: ...ange to the next computer channel MODE button Press to determine which peripherals should be switched to another computer channel will occur when the COMPUTER button is pressed 4 3 2 1 5V 2 5A I N D O...

Page 7: ...patch lead Part number VSC23 Power adapter 12 5W and country specific power lead Audio cable 2m 3 5mm stereo jacks Part number VSC22 ww w a dder com 4 3 2 1 AD DER RC4 remote control plus standard 3m...

Page 8: ...the optional remote control the CCS4 USB unit can be situated out of sight within the cabling cradle of a desk or placed adjacent to the connected systems Consult the precautions listed within the Sa...

Page 9: ...from your USB keyboard and mouse to the USB sockets specifically labelled with keyboard and mouse symbols The keyboard and mouse will operate in any of the USB sockets however True Emulation is not a...

Page 10: ...re air cannot circulate to cool the equipment Do not operate the equipment in ambient temperatures exceeding 40 degrees Centigrade Do not place the products in contact with equipment whose surface tem...

Page 11: ...able link from the computer needs to connect the transmit TXD line of the computer to the receive RXD input of the CCS4 USB and also link the ground terminals GND of the two devices See Appendix 1 for...

Page 12: ...ion mode allows you to determine numerous aspects of the CCS4 USB unit capabilities To use the configuration menu During normal use the seven segment display on the control panel shows the number of t...

Page 13: ...will show momentarily 4 Press and then to exit the menu and save changes To show the current firmware version 1 Enter the Configuration menu 2 Press to enter the Functions menu 3 Press and then The di...

Page 14: ...een names if used are not downloaded to the CCS4 USB unit 1A 2A 3A 4A 1A 2A 3A 4A 1A 2A 3A 4A The important thing is to define where each screen edge abuts to the next so that the CCS USB unit can det...

Page 15: ...e image this option allows you to determine which port should be enabled whenever the CCS4 USB unit is first powered on Switch Mode Located within Configure Switch menu item see above image these chec...

Page 16: ...upply plug from the rear panel of the unit 3 Connect the upgrade computer to the CCS4 USB unit Connect the supplied Flash Upgrade Adaptor to the serial port of the Windows based computer and then link...

Page 17: ...log IMPORTANT Check that the Intended Target Units field matches the Unit Connected field If these fields do not match then you may have an incorrect upgrade file check with Adder Technology Ltd befor...

Page 18: ...channel to automatically change and will jump to the next screen Notes Free Flow cannot be enabled until a layout has been configured and downloaded to the CCS4 USB unit see Free Flow configuration Th...

Page 19: ...uter However if these particular hotkeys clash with another device or program you can change them to a different combination within the Configuration menu Additional hotkey press combinations In addit...

Page 20: ...is reached release the middle button When using this method of switching The computer channels that are visited depend upon the configuration menu setting see note The ports K M audio and or USB that...

Page 21: ...not case sensitive and can be any combination of key strokes including the function keys but excluding the Num Lock Caps Lock Scroll Lock and keys If your keyboard has special media keys these also c...

Page 22: ...Getting assistance If you are still experiencing problems after checking the list of solutions in the Troubleshooting section then we provide a number of other solutions Adder Technology website www a...

Page 23: ...or both types of connector Serial remote control and flash upgrade cable 8p8c Serial remote control and flash upgrade cable 10p10c 8p8c connector D Type female 9 way 6 2 TXD RXD 3 2 3 5 RXD GND TXD GN...

Page 24: ...e it in an enclosed space without any ventilation The CCS4 USB unit does not provide ground isolation and should not be used for any applications that require ground isolation or galvanic isolation Wh...

Page 25: ...eiver is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency energy and...

Page 26: ...imited Technology House Trafalgar Way Bar Hill Cambridge CB23 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 350R Merrimac Street Newburyport MA 01950 United States of...

Reviews: