Warranty

Adder Technology Ltd warrants that this product shall be free from defects in 
workmanship and materials for a period of two years from the date of original 
purchase. If the product should fail to operate correctly in normal use during the 
warranty period, Adder will replace or repair it free of charge. No liability can be 
accepted for damage due to misuse or circumstances outside Adder’s control. 
Also Adder will not be responsible for any loss, damage or injury arising directly 
or indirectly from the use of this product. Adder’s total liability under the terms 
of this warranty shall in all circumstances be limited to the replacement value of 
this product.
If any difficulty is experienced in the installation or use of this product that you 
are unable to resolve, please contact your supplier.

Safety information

•  For use in dry, oil free indoor environments only.
•  do not use to link between buildings.
•  Ensure that all twisted pair interconnect cables are installed in compliance 

with all applicable wiring regulations. 

•  do not connect CATx link interfaces (RJ45 style connectors) to any other 

equipment, particularly network or telecommunications equipment.

•  Warning – the power adapter contains live parts.
•  No user serviceable parts are contained within the power adapter - do not 

dismantle.

•  Plug the power adapter into a socket outlet close to the X200 module that it 

is powering.

•  Replace the power adapter with a manufacturer approved type only. 
•  do not use the power adapter if the power adapter case becomes damaged, 

cracked or broken or if you suspect that it is not operating properly.

•  If you use a power extension cord with the X200 module, make sure the 

total ampere rating of the devices plugged into the extension cord do not 
exceed the cord’s ampere rating. Also, make sure that the total ampere 
rating of all the devices plugged into the wall outlet does not exceed the 
wall outlet’s ampere rating.

•  do not attempt to service the modules yourself.
•  The X200 module and power supply can get warm in operation – do not 

situate them in an enclosed space without any ventilation. 

•  The X200 module does not provide ground isolation and should not be used 

for any applications that require ground isolation or galvanic isolation. 

Summary of Contents for Adder X00 Extender

Page 1: ...REMOTE ADDER PW R TO LOCAL 1 TO LOCAL 2 Adder X200 Extender User Guide...

Page 2: ...tem 8 Special configuration Configuration 9 What are hotkeys 9 Entering using and exiting configuration mode 9 Password setting 10 Mouse switching control 10 Hot plugging PS 2 style connections and mo...

Page 3: ...ory 5 5e or 6 twisted pair cabling Special circuitry within the remote module allows you to make adjustments to the sharpness and brightness settings to suit your own preferences PSU X200 CAM CAM PC1...

Page 4: ...able with or without audio and skew compensation capabilities Serial flash upgrade cable 4 way jack connector to 9 way D type male serial connector not pictured Part number CAB 9DF RJ9 2M What you may...

Page 5: ...networks While these uneven twists work well for Ethernet signals they can impose problems for the video signals transceived by the X200 modules The X200 modules send the red green and blue video sign...

Page 6: ...to the socket of the CAM The other end of each cable run will attach to the remote X200 module Computer Access Module Category 5 5e or 6 cable to X200 module Green indicator power present Yellow indi...

Page 7: ...lled POWER 5 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply Connect the other end of the power lead to a nearby mains socket 6 Where necessary us...

Page 8: ...1 OFF Normal operation ON Before power is applied Places the X200 module into flash upgrade mode so that the internal software can be changed Please see the Flash upgrade section in the Special config...

Page 9: ...ators adjacent to the CATx connectors on the X200 module will be lit To unlock the system 1 Enter the correct password and press Note Passwords are NOT case sensitive Note If an invalid password has b...

Page 10: ...s are also needed for computer tasks you can change them for another combination using switches 2 and 3 on the X200 remote module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2 ON 3...

Page 11: ...tings 1 Connect the X200 module to a computer in the same manner as you would to carry out a flash upgrade see Performing flash upgrades 2 While power is applied set the X200 upgrade switch SW1 to its...

Page 12: ...t is likely to support the Intellimouse format If you have a Microsoft mouse then it will usually state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot...

Page 13: ...rd indicators Num Lock Caps Lock and Scroll Lock will now begin to flash in sequence The speed of the sequence indicates the level of the sharpness adjustment currently applied the slower the rate the...

Page 14: ...8 6 5 2 Data signal Red video signal Green video signal Blue video signal 7 3 4 1 7 3 4 1 To use skew adjustment 1 Display a skew pattern on the appropriate computer You can either use the supplied s...

Page 15: ...el Corresponding keyboard indicators will flash rapidly to show which channel is currently selected for adjustment Num Lock for Red Caps Lock for Green and Scroll Lock for Blue Advance colour timing R...

Page 16: ...nto its ON position 3 Use the optional upgrade cable to link between the socket adjacent to the X200 switch block and a vacant RS232 9 way serial port of the computer system to be used R E M O T E A D...

Page 17: ...ick the Upload Now button The progress will be shown within the dialog Should you decide not to continue with the upload at any stage click the Abort button response to this is usually immediate howev...

Page 18: ...information Getting assistance Adder Technology website www adder com Check the Support section of our website for the latest solutions and driver files Email support adder com Fax in the UK 01954 780...

Page 19: ...d in compliance with all applicable wiring regulations Do not connect CATx link interfaces RJ45 style connectors to any other equipment particularly network or telecommunications equipment Warning the...

Page 20: ...b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an e...

Page 21: ...imited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 29 Water Street Newburyport MA 01950 United States of Americ...

Reviews: