Video skew adjustment (X200AS models only)

The category 5, 5e and 6 cabling supported by the AdderView CATx consists of 
four pairs of wires per cable. Three of these pairs are used to convey red, green 
and blue video signals to the remote video monitor. due to the slight difference 
in twist rate between these three pairs, the 
red, green and blue video signals may not 
arrive at precisely the same time. This is 
visible as separate colour shadows on high 
contrast screen images and is particularly 
apparent when using higher screen 
resolutions and some types of category 5e 
cables.
To alleviate this situation, the Adder 
X200AS modules provide internal skew 
adjustment that can help to rectify the 
situation. The skew adjustment works by 
delaying or advancing the timing of any 
of the red, green or blue colour signals so 
that they are all delivered to the monitor 
at precisely the same time. For best results, the “skew” program supplied on 
the disk or downloadable from 

www.adder.com

 or 

www.adder.info

 is the 

most accurate way of setting skew as the red, green and blue lines are rendered 
exactly on the screen as single pixel wide lines. The skew.bmp test pattern can 
also be used but it is less accurate. Alternatively, you can create your own skew 
pattern using a standard image creation package, as detailed opposite.

Convergence test 
pattern showing the 
RGB crosses. In this 
case, the green signal 
can be seen out of 
line with the other 
two colours.

1 2 3 4 5 6 7 8

8

6

5

2

8

6

5

2

Data signal

Red

video signal

Green

video signal

Blue

video signal

7

3

4

1

7

3

4

1

To use skew adjustment

1  display a skew pattern on the appropriate computer. You can either use the 

supplied skew pattern or create your own:

Using the supplied skew pattern

i  Insert the supplied Adder Installation Cd-ROM into the Cd player of the 

computer.

ii  Within Windows, use the 

My Computer

 

option (usually available as a desktop icon 
or within the Start menu) to view the 
contents of the Cd-ROM. double-click 
the 

Skew

 entry to display the standard 

test pattern. If necessary, maximise the 
application window so that the image fills 
the screen.     

  The screen will show a series of fine red, 

green and blue crosses which should all be 
in line, vertically and horizontally. Skew affects the horizontal placement of 
the colours and using this pattern it is much easier to discover which, if any, 
colours are being adversely affected by the cable link.  

Creating a skew test pattern

skew test pattern  

i  Run any image creation/editing application, such as the Paint program 

supplied with Windows.

ii  Using the image application create three 

stacked horizontal rectangles (one red, 
one green and one blue) that fill the 
width of the screen.

iii  draw a vertical black line down across 

the coloured bars and then repeat this 
vertical line at intervals along the width 
of the coloured bars. These lines create 
breaks across the colours and give you 
more opportunities to view the horizontal 
position of each colour relative to the others. 

2  On the keyboard connected to the X200AS, simultaneously, press the 

hotkeys (by default, 

 and 

) along with 

 to enter configuration 

mode.

The three keyboard indicators (‘Num Lock’, 
‘Caps Lock’ and ‘Scroll Lock’) will now begin 
to flash in sequence.  

Summary of Contents for Adder X00 Extender

Page 1: ...REMOTE ADDER PW R TO LOCAL 1 TO LOCAL 2 Adder X200 Extender User Guide...

Page 2: ...tem 8 Special configuration Configuration 9 What are hotkeys 9 Entering using and exiting configuration mode 9 Password setting 10 Mouse switching control 10 Hot plugging PS 2 style connections and mo...

Page 3: ...ory 5 5e or 6 twisted pair cabling Special circuitry within the remote module allows you to make adjustments to the sharpness and brightness settings to suit your own preferences PSU X200 CAM CAM PC1...

Page 4: ...able with or without audio and skew compensation capabilities Serial flash upgrade cable 4 way jack connector to 9 way D type male serial connector not pictured Part number CAB 9DF RJ9 2M What you may...

Page 5: ...networks While these uneven twists work well for Ethernet signals they can impose problems for the video signals transceived by the X200 modules The X200 modules send the red green and blue video sign...

Page 6: ...to the socket of the CAM The other end of each cable run will attach to the remote X200 module Computer Access Module Category 5 5e or 6 cable to X200 module Green indicator power present Yellow indi...

Page 7: ...lled POWER 5 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply Connect the other end of the power lead to a nearby mains socket 6 Where necessary us...

Page 8: ...1 OFF Normal operation ON Before power is applied Places the X200 module into flash upgrade mode so that the internal software can be changed Please see the Flash upgrade section in the Special config...

Page 9: ...ators adjacent to the CATx connectors on the X200 module will be lit To unlock the system 1 Enter the correct password and press Note Passwords are NOT case sensitive Note If an invalid password has b...

Page 10: ...s are also needed for computer tasks you can change them for another combination using switches 2 and 3 on the X200 remote module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2 ON 3...

Page 11: ...tings 1 Connect the X200 module to a computer in the same manner as you would to carry out a flash upgrade see Performing flash upgrades 2 While power is applied set the X200 upgrade switch SW1 to its...

Page 12: ...t is likely to support the Intellimouse format If you have a Microsoft mouse then it will usually state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot...

Page 13: ...rd indicators Num Lock Caps Lock and Scroll Lock will now begin to flash in sequence The speed of the sequence indicates the level of the sharpness adjustment currently applied the slower the rate the...

Page 14: ...8 6 5 2 Data signal Red video signal Green video signal Blue video signal 7 3 4 1 7 3 4 1 To use skew adjustment 1 Display a skew pattern on the appropriate computer You can either use the supplied s...

Page 15: ...el Corresponding keyboard indicators will flash rapidly to show which channel is currently selected for adjustment Num Lock for Red Caps Lock for Green and Scroll Lock for Blue Advance colour timing R...

Page 16: ...nto its ON position 3 Use the optional upgrade cable to link between the socket adjacent to the X200 switch block and a vacant RS232 9 way serial port of the computer system to be used R E M O T E A D...

Page 17: ...ick the Upload Now button The progress will be shown within the dialog Should you decide not to continue with the upload at any stage click the Abort button response to this is usually immediate howev...

Page 18: ...information Getting assistance Adder Technology website www adder com Check the Support section of our website for the latest solutions and driver files Email support adder com Fax in the UK 01954 780...

Page 19: ...d in compliance with all applicable wiring regulations Do not connect CATx link interfaces RJ45 style connectors to any other equipment particularly network or telecommunications equipment Warning the...

Page 20: ...b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an e...

Page 21: ...imited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 29 Water Street Newburyport MA 01950 United States of Americ...

Reviews: