background image

SR-20RM

 

USER GUIDE

  

PLUG INTO THE FUTURE OF TECHNOLOGY

Summary of Contents for SR-20RM

Page 1: ...SR 20RM USER GUIDE PLUG INTO THE FUTURE OF TECHNOLOGY ...

Page 2: ...2 WWW ADDC NET 516 673 4444 INFO ADDC NET ALL PRODUCTS ARE PROUDLY MADE IN THE USA Revision History Revision Notes V2 3 Revision 2 3 was published in February of 2022 ...

Page 3: ...Section 2 4 SR 20 RM Power Supplies 10 Section 2 5 Networking Your SR 20RM 11 Section 2 6 Powering On Your SR 20RM 12 Section 3 SR 20RM Overview 13 Section 3 1 SR 10 Modules 14 Section 3 2 Rear Panel 15 Section 3 3 Front Panel 16 Section 4 ROMware Software 17 Section 4 1 Login 17 Section 4 2 Main Screen Overview 17 Section 4 3 SR 10 Switch Configuration 18 Section 4 4 BioDigitalPC Power Control Mo...

Page 4: ...e of the chassis and notable features of the SR 20 RM server solution Installations will be supported by ADDC Unless otherwise specified all instructions provided in this manual will assume that a user is a trained technician How to Read this Document You will see this icon throughout the manual intended to point out warnings important information and briefly explain any new terminology ...

Page 5: ...quipment Included SR 20RM Chassis SR 20RM Top Cover Comes Assembled BioDigitalPC Server Cards Check Invoice for Quantity 2 AC DC Power Supplies 4 10Gbps SFP Cables 2 AC Power Cords 2 Rack Slides Section 1 1 What s in the Box 10Gbps SFP Cables SR 20RM Chassis SR 20RM Top Cover Rack Slides AC DC Power Supplies AC Power Cords Section 1 0 Recieving Your SR 20RM ...

Page 6: ...ont of the rack Leave a minimum clearance of 8in 20 32cm behind the rack Temperature Considerations Your SR 20RM is designed to operate at room temperature with its self contained cooling Power Considerations When properly configured and installed the SR 20RM can draw up to 800 Watts depending on the number load and version of the BioDigitalPC s used To prevent improper cooling of equipment do not...

Page 7: ...ck stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over and cause severe injury to the technicians and damage to the device This section provides information on installing the SR 20RM chassis into a rack unit with the quick release rails provided Mount Rack Slides on t...

Page 8: ... technicians are authorized to work beneath the SR 20RM System Cover and access any of the components inside the system Section 2 3 2 Installing a BioDigitalPC Step 3 Insert Card with Arnouse Digital Devices Corp facing upwards and the connector of the card is facing towards the latch When inserting the card place between the two horizontal metal bars ensuring the card is going to be aligned prope...

Page 9: ...ock the locking tab Section 2 3 4 Replacing the SR 20RM Top Cover Section 2 3 3 Removing a BioDigitalPC Section 2 3 Installing Your BioDigitalPC s Once complete a technician should replace the SR 20RM Top Cover Step 3 Lift to remove the card from its slot Step 2 Pull the ejection bar forward towards you you should feel the card pop out of the connector ...

Page 10: ...Power Cord into the replacement SR 20RM Power Supply 4 You should see the OK LED illuminated green Handle Tab Correct orientation pictured inserting power supplies upside down may damage the system The SR 20RM requires one power supply for the system to operate optimally Each power supply powers 10 PC cards To ensure redundancy see the power supply schemas in Section 2 6 Remove and replace only on...

Page 11: ... ROMWare Switch Management Section 2 5 4 10Gbps Networking without Out of Band Switch Management 1 10 100 Ethernet Cable 1 External Computer eg a laptop 2 10 100 Ethernet Cables 1 10 100 1000 Ethernet Cables 2 1 port 10 100 1000 Ethernet Switch 3 10 100 Ethernet Cables 4 1 port or more 10 100 Ethernet Switch 2 10 100 1000 Ethernet Cables All equipment found in Section 2 5 2 plus the following 4 SF...

Page 12: ...ction 2 6 Power On Your SR 20RM Section 2 6 2 Dual Feed Redundant Power Supply Configuration Section 2 6 1 Single Feed Redundant Power Supply Configuration Power Source A Power Source A Power Source B Each Power Source must be capable of the maximum draw of 650W There is no power button ...

Page 13: ...13 WWW ADDC NET 516 673 4444 INFO ADDC NET ALL PRODUCTS ARE PROUDLY MADE IN THE USA Section 3 SR 20RM Overview Network Connections Module Module Number Card Slot Number Front Interface ...

Page 14: ...ving three 1Gbps NICs attached to an integrated switch Each switch has two SFP 10Gbps connectors and one 1Gbps RJ 45 connector broken out to the rear panel of the SR 20RM See Section 3 2 for additional information Each SR 10 s integrated switch and BioDigitalPC power control are managed via the SR 20RM s Web based management program called ROMWare See Section 4 for additional information Section 3...

Page 15: ...and Switch Hardware Ports 1Gbps Ports Section 3 2 Rear Panel Switch Management Ports Power Management Ports ROMware AC Power 10Gbps SFP Ports Section 3 2 2 Management Switch and 10Gbps SFP Ports Section 3 2 1 AC Power 1 2 KVM Modules Port 1Gb Ports RS232 Switch Serial Management Ports 10 Gbps SFP Ports ...

Page 16: ... SR 10 s primary 10Gbps SFP Port 10G B An SR 10 s secondary 10Gbps SFP Port 1G AUX An SR 10 s auxiliary one Gigabit An individual slot s 1Gbps NIC LEDs One LED for each 1Gbps NIC 10G A 10G B 1G AUX 10G A 10G B 1G AUX Module 2 Module Power Buttons Touch Screen that can control each individual card I E Reboot shutdown power on ...

Page 17: ...are asks for credentials to log in and begin management and or monitoring of your SR 20RM Users are supplied with administrative credentials that have been factory set Only one admin can be logged in at once through the IP 10 0 1 254 Section 4 1 Login Section 4 ROMware Software Section 4 2 Main Screen Overview ...

Page 18: ...turn On and Off each SR 10 Power Module Clear Faults will clear faults for this SR 10 s power supply To verify the SR 10 s Power Supply is operating optimally you can press the button labeled Power for more information Section 4 3 DC Power Control Monitoring Clicking on a box will show more information regarding the current status of the DC Power Supplies ...

Page 19: ...ves power from the BioDigitalPC Server card Sends a signal to the BioDigitalPC Server card to shut down gracefully Removes power from the BioDigitalPC Server card waits 30 seconds and then applies power back to the BioDigitalPC Server card Removes power from the remote power control Do not use this unless specifically instructed to Gracefully reboots the BioDigitalPC Server card Section 4 4 BioDig...

Page 20: ...ique SR 20RM slot number SR 10 Module Position The position number of the SR 10 Module within the SR 20RM BioDigitalPC Slot Position The Position of the Slot within the SR 10 Current Status Displays the current status of the slot Present Not Present On and Off Hardware Information Click View to show the Slot Hardware Information See the page 21 for more information ...

Page 21: ...this SR 10 module Is Auto Power On Enabled With this enabled after boot up of the SR 20RM the BioDigitalPC in this slot will be powered on if present after delay number of seconds Delay The number of seconds to wait after power up of the SR 20RM before powering on the BioDigitalPC if present in this slot MAC Address 1 2 3 MAC addresses of the 3 1Gbps NICS for this slot ...

Page 22: ... MADE IN THE USA Section 4 5 SR 20RM System Settings Click on the cog to access the Systems Settings The System Settings allows the user to change four things ROMware password the machines IP address the machines Gateway and the ability to enable or disable the Keypad ...

Page 23: ...DD Stack ADD FDD is used to add SR 20RM s together to a stack This allows you to access all of your SR 20RMs from one interface Refresh FDD Stack button Upon clicking on Add FDD this box will appear Fill out FDD IP Adress and FDD Name and the corresponding SR 20RM will be added to the FDD Stack 10 0 1 134 ...

Page 24: ...24 WWW ADDC NET 516 673 4444 INFO ADDC NET ALL PRODUCTS ARE PROUDLY MADE IN THE USA The Connect button will add the SR 20RM ot the FDD Stack Section 4 6 SR 20RM FDD Stack ...

Page 25: ...73 4444 INFO ADDC NET ALL PRODUCTS ARE PROUDLY MADE IN THE USA After Connecting to the added SR 20RM your screen will now show the new SR 20RM as the Controlling FDD Controlling FDD 10 0 1 134 Section 4 6 SR 20RM FDD Stack ...

Page 26: ... USA Section 4 7 Front Panel Touchscreen Overview System Startup Screen Allow 3 4 minutes for system to boot up ADDC Support Screen This screen is displayed right after the system boots up and will be closed after ten seconds or it can also be closed by clicking on the red button ...

Page 27: ...FF GREEN indicates that there is a PC Card installed and turned ON Click on question mark button to recall the ADDC support screen Module 1 Selected PC Card installed but turned OFF on slot 1 No PC Cards installed on slots 2 10 PC Card installed and turned ON on slot 1 no PC Cards installed on slots 2 10 Notice that corresponding NIC LEDs are illuminated indicating that the PC Card s NICs are conn...

Page 28: ...d by clicking on the red button Powers ON the BioDigitalPC Server card Immediately removes power from the BioDigitalPC Server card Sends a signal to the BioDigitalPC Server card to shut down gracefully Removes power from the BioDigitalPC Server card waits 30 seconds and then applies power back to the BioDigitalPC Server card Removes power from the remote power control Do not use this unless specif...

Page 29: ... number 123123 to access the PC Card Slots Power Status Screen It is recommended that you change the default pin number it can be changed from ROMWare Lite When the lock screen is enabled there will be a logout button next to the question mark button the logout button will lock the screen There is a default session timeout of six minutes if there is no user activity in six minutes the session will...

Reviews: