Adcon M433LC Technical Manual Download Page 21

 

Copyright Adcon RF Technology 2002 

LC-Ind Modems Technical Manual 

Rev: 1.0 

Page: 21

 

4.2.2 Standard commands 

  

 

 

Command  Description 

 

Operating mode 

ATO 

Activate transparent Mode  

“ATO” sets up the Module to transparent mode. To return to Hayes Mode, enter a 

‘+++’ sequence. 

+++ 

Activate 'AT' Mode. 

“+++” Gives an instant access to the modem parameter set-up mode (AT or Hayes 

Mode). ‘+++’ Command shall not be started with AT and ended by <CR>, but 

entered between a silent time duration (time-out) which parameter is defined in 

milliseconds in Register S214 (i.e. <time-out>’+++’<time-out>). 
Note: By activating the ‘AT’ Mode, LC-IND modems inactivate radio reception. 

 

Register Handling 

ATSn? 

Display of Register S Number N contents. 

LC-IND modems operating parameters are stored in ‘S’ classified Registers. S 

Registers are numbered from 0 to 512. Some parameters are standard for every 

Hayes type modems, other are specific to LC-IND units. 

ATSn=m 

Entering m value into Register S – Number n. 

A new parameter entered is Register S is automatically stored in the modem EEPROM 

memory. 

AT/S 

Clear Display of Significant Registers contents. 

Every significant register for the modem (radio configuration, Serial configuration, 

operating Mode,) are sent to the serial link, ready to be clearly displayed by a Software 

such as Windows «Terminal». 

AT/V 

Clear Display of the Modem Software version.  

Information concerning the version number and installation date is sent on the Serial Link 

in clear; ready to be displayed by Software such as Windows «Terminal». 

 

Test Functions 

ATTO 

Pure carrier transmission

 (for testing purposes) 

ATT1 

F0 modulated carrier transmission

 (for testing purposes) 

ATT2 

F1 modulated carrier transmission

 (for testing purposes) 

ATT3 

Alternative F0-F1 modulated carrier transmission

 (for testing purposes) 

Summary of Contents for M433LC

Page 1: ...M433LC Radio Modem ETSI 300 220 Technical Manual ISSUE 4 0 UPDATE 19 08 2002...

Page 2: ...mes mentioned in this document may be trademarks or registered trademarks of their respective companies All rights reserved Neither the whole nor any part of the information contained in this publicat...

Page 3: ...ristics 5 2 2 Connections 5 2 3 Diagrams 7 3 BASIC OPERATION USING MTC 8 3 1 The desktop 8 3 1 1 The menu bar 10 3 1 2 The tool bar 12 3 1 3 The application Tree 13 3 2 Peer to peer dialog 15 3 2 1 Co...

Page 4: ...he 433 MHz frequency band in compliance with the ETSI 300 220 European regulation Operating a 10 mW radiated power LC Ind modems can be used without any license The LC Ind modem is based on synthesise...

Page 5: ...diated power 10 dBm 10 mW in transmission Data error rating 10 4 for 90 dBm Communication range up to 1000 m in free field Operating temperature 0 C 50 C Dimensions 89 x 64 x 24 mm Weight 150 g 2 2 Co...

Page 6: ...Copyright Adcon RF Technology 2002 M433LC Ind Modem Technical Manual Rev 4 0 Page 6...

Page 7: ...2 3 Diagrams Ec helle 1 89 64 4xinserts M3 69 44 24 63...

Page 8: ...ia various hardware interfaces RS232 RS422 can be tested and configured at the same time The framework provides a desktop to display test and configure multiple modems including LC Ind radio modem wit...

Page 9: ...rts the following desktop is displayed A visual check that the software detected the radio modem during auto configuration can be done by clicking on the COM1 node The radio modem should appear as a c...

Page 10: ...esktop to an advanced operation desktop and vice versa The current description concerns the basic user level configuration For the advanced user level configuration description refer to the MTC Workbe...

Page 11: ...l dialog window between two given radio modules already configured with all necessary network parameters i e mode network and clients IDs The ports are chosen by the user Note It is not applicable to...

Page 12: ...cable in certain conditions and are therefore disabled elsewhere 1 2 3 4 The buttons functions are listed in the following table N NAME FUNCTION ACTION 1 Channel scanning Channel scanning of the curre...

Page 13: ...connected modems detected during auto configuration and the modem configuration files found in the application configuration file The application tree is composed of two windows that can not be close...

Page 14: ...different configuration files available sorted by type of modem It is not available in basic user level configuration Ports Window The About port window gives information about the status of each seri...

Page 15: ...o be selected A window allowing the user configuring two compatible radio units for peer to peer dialog is displayed Both operating mode and communication channel should be chosen by the user Once the...

Page 16: ...displayed on top of the panel it gives the type of module and the port it is connected to E g 433 LC COM1 Received data This non editable field displays the data received on the radio link from the o...

Page 17: ...Provides the number of errors occurring during a transmission Those errors are counted in characters Send button Sends the frame previously entered by the user in the data to send field to the other...

Page 18: ...Hayes mode NOTE The user s software application must adequately verify that all buffers are transmitted correctly taking into account that an interrupted transmission link may lead to losing one or s...

Page 19: ...de Serial data Data No 1 Data No 2 Rx TX switch 5 5 ms Carrier standard time 15 ms Data No 1 Data No 2 Time Out 5 ms Register S214 Carrier detect End carrier process Data No 1 Data No 2 RS 232 Recepti...

Page 20: ...nd CR The only exception to this data framing rule is the switching command from Transparent Mode to AT Mode In this case only the escape code by default must be started and followed by a silent time...

Page 21: ...ed from 0 to 512 Some parameters are standard for every Hayes type modems other are specific to LC IND units ATSn m Entering m value into Register S Number n A new parameter entered is Register S is a...

Page 22: ...tes the value of the time out on the serial link in ms Included between 1 and 255 Default value 5 ms Scanning R W S216 Status format during scanning Status can be delivered as a binary value or ASCII...

Page 23: ...sion Date Author Subject 0 1 98 GS Creation 1 0 99 GS Updates according to development 2 0 00 MHB Updates according to development 3 0 01 MHB Updates and re design 4 0 08 02 SG Updates and MTC integra...

Reviews: