27
•
Parameterization of the "Slave" Modem:
Before parametering the Slave Modem, the Server must have been configured and must be in
Acquisition Mode.
User:
+++
/* Run in Hayes Mode. */
Modem response: O<CR>
User:
ATS200=3<CR>
/* Choice of the Frequency Table 3. */
Modem response: O<CR>
User:
ATS201=0<CR>
/* Choice of No. 1 Synchronization Frequency. */
Modem response: O<CR>
User:
ATS202=10<CR>
/* Choice of No. 2 Synchronization Frequency. */
Modem response: O<CR>
User:
ATS203=20<CR>
/* Choice of No. 3 Synchronization Frequency. */
Modem response: O<CR>
User:
ATS204=30<CR>
/* Choice of No. 4 Synchronization Frequency. */
Modem response: O<CR>
User:
ATS220=3<CR>
/* Choice of Slave Mode. */
Modem response: O<CR>
User:
ATS250=0<CR>
/* Indicates Uncoded Slave (No Personal Network No.).
*/
Modem response: O<CR>
User:
ATM1<CR>
/* Runs in Acquisition Mode */
Modem response: O<CR>
At this time, the two Modems have to acquire themselves, and the Slave Modem sends:
Modem response: S250=1<CR>S252=1<CR>
/* Indicates
Acquisition
done */
User:
AT0<CR>
/* Runs in Security Transparent Mode */
Modem response:
O<CR>