background image

 

©

 2009  ADC CORPORATION 

 

  First printing    February 28, 2009 

 

All 

rights 

reserved. 

     

 

 

Printed 

in 

Japan 

 

 

12701A 

Test Fixture 

OPERATION MANUAL 

Manual Number    FOE-00000045A00 

Summary of Contents for 12701A

Page 1: ...2009 ADC CORPORATION First printing February 28 2009 All rights reserved Printed in Japan 12701A Test Fixture OPERATION MANUAL Manual Number FOE 00000045A00...

Page 2: ......

Page 3: ...Close the cover during measurement to perform accurate measurement The cover has a shielded light shielded and safety structure 6 Watch out for vibration to perform accurate measurement The vibration...

Page 4: ......

Page 5: ...Transportation of the Product Be sure to read through this chapter before use 2 Panel Description 1 Relay Terminals 2 Rear Panel Describes the name and function of each part on the panel 3 Measuremen...

Page 6: ......

Page 7: ...e 1 6 1 5 3 Transportation 1 6 2 Panel Descriptions 2 1 2 1 Relay Terminals 2 1 2 2 Rear Panel 2 3 3 Measurement Examples 3 1 3 1 High Resistance Measurement 3 1 3 2 Resistance Measurement 3 6 3 3 Dio...

Page 8: ......

Page 9: ...he 12701A with the 6245 3 7 3 6 Connecting the Relay Terminals with the Test Box 3 9 3 7 12701A and 6245 Connection Diagram 4 wire Connection 3 10 3 8 Connecting the 12701A with the 6245 3 13 3 9 Conn...

Page 10: ......

Page 11: ...T 1 12701A Test Fixture Operation Manual List of Tables No Title Page 1 1 Supplied Accessories 2 1...

Page 12: ......

Page 13: ...rent source monitor 6243 6245 6246 to perform DC characteristics tests of semiconductors and other electronic components It allows easy connection of DUTs to a measuring instrument and offers stable m...

Page 14: ...supplied with the 12701A If there is any damage or defect please contact ADC Corporation or your sales representative Quote the model name of the accessory when ordering Table 1 1 Supplied Accessories...

Page 15: ...ccessories 1 Test boxes Name Model Remarks Diode test box A04501 Axial lead type measurement socket Applicable to diodes and resistors Insulating board A04506 Teflon board Teflon area 140 x 90 mm Powe...

Page 16: ...mini socket connection lead with mini hook A01228 15 2x2 dia 1 dia coaxial cable connection lead A01229 15 2x2 dia 1x2 dia coaxial cable connection lead A01287 15 2 dia 2 dia connection lead for high...

Page 17: ...Operating temperature range Maximum input current Operating temperature range 0 A to 5 A 20 C to 75 C 5 1 A to 10 A 20 C to 70 C 10 1 A to 20 A 20 C to 65 C z Relative humidity 85 or less with no cond...

Page 18: ...om dust and direct sunlight When storing it for an extended period 90 days or longer put the 12701A in a moisture proof bag together with desiccants 1 5 3 Transportation To transport the 12701A use th...

Page 19: ...ons This chapter describes the following items 1 Relay terminal 2 Rear panel 2 1 Relay Terminals The relay terminals connect to the test box socket using the connection leads The relay terminals conne...

Page 20: ...panel Its potential is equal to those of the outer shields of the case and the triaxial connectors 6 TEST BOX GUARD Connects with the mount of the test box socket See Figure 3 2 Ensure to connect it t...

Page 21: ...ENSE LO OUTPUT and LO SENSE of the 6245 and 6246 Bch 2 GND safety connector The potential is equal to those of the outer shields of the case and the triaxial connectors 3 VS1 HI and LO safety connecto...

Page 22: ...OPERATE of the 6246 the INTERLOCK of the 8252 6245 or 6246 or the LID SIGNAL of the 8340A voltage or current generation from the measuring instrument automatically stops when the cover of the 12701A...

Page 23: ...urrent measurement using the 8252 digital electrometer 3 1 High Resistance Measurement This section describes the procedure of implementing high resistance measurement using the 8340A digital ultra hi...

Page 24: ...BNC cable A01036 2 TRIAX TRIAX cable A01009 3 Banana banana cable A01240 LID SIGNAL FORCE SENSE 1 VS2 HI LID SIGNAL INPUT V SOURCE Installing the test box 6 Place the test box on the mount section of...

Page 25: ...E DG 1 Connect the relay terminal FORCE SENSE HI 1 and the test box 1 using the connection lead 9 Prepare the 2 dia 2 dia connection lead A01215 15 Connect the TEST BOX GUARD onto the plug where the c...

Page 26: ...nnection cable Relay terminal Test box 1 2x2 dia 1 dia coaxial cable connection lead A01228 15 2 2 dia 2 dia connection lead A01215 15 3 2 dia 1 dia connection lead A01214 20 DG 1 HI 1 DG 1 TEST BOX G...

Page 27: ...ment range to AUTO Press the AUTO key The LED light goes on 13 Set to MEASURE Press the MEASURE key The LED light goes on 14 Set the source voltage to IV Press the SET AUTO 1 and SEST ENTER keys Conne...

Page 28: ...6245 1 Ground the 12701A and the 6245 2 Connect the LID SIGNAL of the 12701A and the INTERLOCK of the 6245 using the BNC BNC cable A01036 3 Connect the FORCE SENSE 1 of the 12701A and the HI OUTPUT o...

Page 29: ...able A01009 4 TRIAX TRIAX cable A01009 LID SIGNAL FORCE SENSE 1 FORCE SENSE 2 FORCE SENSE 3 INTERLOCK HI OUTPUT HI SENSE LO SENSE LO OUTPUT Figure 3 5 Connecting the 12701A with the 6245 Installing th...

Page 30: ...nnection lead to the relay terminal FORCE SENSE DG 2 Connect the relay terminal FORCE SENSE HI 2 and the test box 2 using the connection lead 10 Prepare the 2 dia 2 dia connection lead A01215 15 Conne...

Page 31: ...ial cable connection lead A01228 15 2 2x2 dia 1 dia coaxial cable connection lead A01228 15 3 2 dia 2 dia connection lead A01215 15 4 2 dia 1 dia connection lead A01214 20 5 2 dia 1 dia connection lea...

Page 32: ...l Press the CH key to set to CH A 14 Set the measurement mode to DC source Press the DC key 15 Set the function to voltage source Press the V I key to set to VS 16 Set the source voltage value 17 Set...

Page 33: ...nnecting DUT 20 Check that the OPERATE key of the 6245 is turned off LED light off 21 Mount DUT onto the test box 22 Close the cover Applying voltage 23 Press the OPERATE key of the 6245 The LED light...

Page 34: ...e 6245 DC voltage current source monitor Connecting the 12701A with the 6245 1 Ground the 12701A and the 6245 2 Connect the LID SIGNAL of the 12701A and the INTERLOCK of the 6245 using the BNC BNC cab...

Page 35: ...X cable A01009 3 TRIAX TRIAX cable A01009 LID SIGNAL FORCE SENSE 1 FORCE SENSE 3 INTERLOCK HI OUTPUT LO SENSE LO OUTPUT Figure 3 8 Connecting the 12701A with the 6245 Installing the test box 5 Place t...

Page 36: ...Connect the relay terminal FORCE SENSE DG 3 and the TEST BOX GUARD 9 Prepare the 2 dia 1 dia connection lead A01214 20 Connect the test box 3 onto the plug where the connection lead A01215 15 is conn...

Page 37: ...et the measurement mode to DC source Press the DC key 12 Set the function to voltage source Press the V I key to set to VS 13 Set the source voltage value 14 Set the compliance limit 15 Set the measur...

Page 38: ...on Manual 3 3 Diode Leak Current Measurement 18 Mount DUT onto the test box 19 Close the cover Applying voltage 20 Press the OPERATE key of the 6245 The LED light goes on In this way a measured curren...

Page 39: ...4 4 Connect the VS1 LO of the 12701A and the LO GROUND short bar of the 8252 using the output cable A01044 Connection cable 12701A 6245 1 TRIAX TRIAX cable A01009 2 Output cable A01044 3 Output cable...

Page 40: ...n lead to the relay terminal FORCE SENSE DG 1 Connect the relay terminal FORCE SENSE HI 1 and the test box 1 using the connection lead 7 Prepare the 2 dia 2 dia connection lead A01215 15 Connect the T...

Page 41: ...inal Test box 1 2x2 dia 1 dia coaxial cable connection lead A01228 15 2 2 dia 2 dia connection lead A01215 15 3 2 dia 1 dia connection lead A01214 20 4 2 dia 1 dia connection lead A01214 20 DG 1 HI 1...

Page 42: ...3 20 12701A Test Fixture Operation Manual 3 4 Diode Leak Current Measurement Figure 3 13 12701A and 8252 Connection Diagram...

Page 43: ...value indication Press the IM RM key to set to IM 11 Set the measurement range to AUTO 12 Set the source voltage value Connecting DUT 13 Check that the OPERATE key of the 8252 is turned off OUTPUT lig...

Page 44: ......

Page 45: ...00M or higher 2 The driving guard ignores the input cable capacitance Cx1 by driving the core wire of the input cable and the inner shield at the same potential and also ignores Cx2 because of low imp...

Page 46: ...pplied When the HI OUTPUT of the 6245 or 6246 Bch and the FORCE SENSE 1 to 8 on the rear panel of the 12701A are connected and the relay terminal DG 1 to 8 and the TEST BOX GUARD are connected the tes...

Page 47: ...nnection 4 2 Internal Connection The following diagram shows the internal connection between the rear panel the relay terminals and the test box of the 12701A Figure 4 2 Block Diagram Chassis Test box...

Page 48: ......

Page 49: ...Between LID SIGNAL core wire and chassis TTL level 2 Maximum input current VS1 20 A VS2 3 A Triaxial 2 A 3 Dielectric strength 1 minute for each Between triaxial core wire and VS1 HI 300 V Between tr...

Page 50: ...5 2 12701A Test Fixture Operation Manual 5 2 General Specifications 5 2 General Specifications Dimensions Approx 201 W 122 H 243 D mm Mass 1 7 kg or less...

Page 51: ...model and features of the test boxes to be mounted on the 12701A Axial lead type diode or resistance measurement socket Maximum lead diameter up to 1 1 mm Kelvin connection method Two types of sample...

Page 52: ...2 12701A Test Fixture Operation Manual A 1 Test Box Socket Teflon board Teflon section area 140 90 mm Place DUT on it Pick it between the mini hook A04701 12 and the connection lead A01217 25 to measu...

Page 53: ...he 2 dia safety connectors of the relay terminal VS1 HI LO or VS2 HI LO and the 2 dia safety connectors of A04509 FORCE or SENSE using the safety plug connection leads 2 dia supplied with A04509 Use t...

Page 54: ......

Page 55: ...EXT 1 External Dimensions Unit mm Note These figures show the external dimensions of the 12701A The external view may vary depending on the product model or option...

Page 56: ......

Reviews: