LIMITED WARRANTY

American Diagnostic Corporation (ADC

®

) warrants its products against defects

in materials and workmanship under normal use and service as follows:

1.   Warranty service extends to the original retail purchaser only and commences

with the date of delivery.

2.   The optical system is warranted for one year.

What is Covered:

Repair, or replacement of parts, and labor.

What is Not Covered:

Transportation charges to and from ADC

®

. Damages caused by abuse, misuse,

accident, or negligence. Incidental, special, or consequential damages. Some

states do not allow the exclusion or limitation of incidental, special, or conse-

quential damages, so this limitation may not apply to you.

To Obtain Warranty Service:

Send item(s) postage paid to ADC

®

, Attn: Repair Dept., 55 Commerce Dr., Haup-

pauge, NY 11788. Please include your name and address, phone no., proof of

purchase, and a brief note explaining the problem.

Implied Warranty:

Any implied warranty shall be limited in duration to the terms of this warranty

and in no case beyond the original selling price (except where prohibited by law).

This warranty gives you specific legal rights and you may have other rights

which vary from state to state.

Summary of Contents for Proscope 2.5V

Page 1: ...Otoscope Ophthalmoscope Instrument Set Use Care Maintenance ...

Page 2: ...es illumination of the ear canal and tympanic membrane Nasal Speculum Adapter for Otoscope Attachment 5215 only When using the otoscope attachment with a nasal speculum adapter the device allows for direct examination of the nares while maintaining a line of sight Bent Arm Illuminator 5215 only The bent arm illuminator is a handheld light that can be used to illuminate a patient s mouth and upper ...

Page 3: ...he value of radiance were reduced in half twice the time would be needed to reach the maximum exposure limit While no acute optical radiation hazards have been identified for direct or indirect oph thalmoscopes it is recommended that the intensity of light directed into the patient s eye be limited to the minimum level which is necessary for diagnosis Infants aphakes and persons with diseased eyes...

Page 4: ...nd effectiveness of this device This includes steam sterilization WARNING Use of any accessories or materials not indicated in the user s manual can degrade the minimum safety of the equipment CAUTION Federal law restricts this device to sale by or on the order of a physician or licensed health care practitioner WARNING During use metal components near instrument head can become warm This is espec...

Page 5: ...position is off red 1 position is full power Slide the switch in the opposite direction to turn off Fig 3 Handle Care and Maintenance The handle can be cleaned following the guidelines in the Cleaning and Disinfection section below Periodically check the condition of the batteries making sure there is no sign of corrosion or oxidation Always replace BOTH batteries Alka line batteries are recommend...

Page 6: ...and twist coun terclockwise to engage Fig 4b Reverse procedure to re move and discard after each use Removing Viewing lens To remove the Viewing lens Item 5211 L during an exami nation rotate lens counterclockwise and pull Reverse proce dure to attach Fig 5 Replacing lamp Remove speculum Pull black sleeve off of lamp Twist lamp counterclockwise to remove Replace with ADC Item 5211 4 Reverse proced...

Page 7: ... is designed for examination of the oral cavity inconjunction with the tongue depressor blade or laryngeal mirror attachments Supplied attachments include a reusable tongue blade Item 5215 TD adapter for disposable tongue blade Item 5215 TO 3mm laryngeal mirror Item 5215 M3 and 4mm laryngeal mirror Item 5215 M4 These attachments are supplied with complete set Item 5215 only or can be purchased sep...

Page 8: ...specified below These alternate cleaning disinfecting methods have not been vali dated with ADC s devices and may cause damage or corrosion to your medical device All devices and accessories excluding disposable specula should be thoroughly cleaned and disinfected prior to their first use Devices and accessories being sent for repair or servicing must also be disinfected prior to shipping OUTLINE ...

Page 9: ...Reusable Specula Nasal Specula and Bent Arm Illuminator Accessories Including Laryngeal Mirrors Tongue blade and Tongue blade holder Prepare Enzol or equivalent enzymatic cleaning solution as per manufacturer s in structions and soak for ten minutes Enzol is typically prepared at one ounce of product per gallon of water or two ounces of product per gallon of water for cleaning devices with dried o...

Page 10: ... should be visible on the immersed accessories during this soak time The accessories should then be removed from the disinfectant and immersed in purified water to rinse off all disinfectant Immersion should be for a minimum of one minute and the process should be repeated two additional times using fresh purified water each time Once rinsing is complete the accessories should be thoroughly dried ...

Page 11: ...and devices should be allowed to dry for a minimum of two hours to ensure that all moisture has been eliminated prior to reinsertion of batteries Battery handles must be given a visual inspection for corrosion or damage prior to the reinsertion of batteries Check for damaged corroded or discolored parts within the battery compartment Any handles showing signs of damage from cleaning and disinfecti...

Page 12: ...sed Specula mount is damaged Lens mount is damaged Lens is dirty Lens is damaged Lamp near end of useful life Batteries are depleted Damage from excessive moisture Corrective Action Replace the lamp with ADC part 5211 4 Replace the lamp with ADC part 5211 4 Replace with fresh C batteries Service required Use only Welch Allyn brand or compatible Service required Service required Clean with lint fre...

Page 13: ... Thread connection is damaged The aperture dial is not centered Lamp near end of useful life Batteries are depleted Dirt in or damage to mechanism Damage from excessive moisture Corrective Action Rotate Aperture dial Replace the lamp with ADC part 5210 4 Replace the lamp with ADC part 5210 4 Re insert lamp Service required Move aperture dial to the full detent position Replace the lamp with ADC pa...

Page 14: ...rong lamp installed Batteries are depleted Accessories may have reached end of useful life Thread connection is damaged Lamp near end of useful life Batteries are depleted Damage from excessive moisture Corrective Action Replace the lamp with ADC part 5211 4 Replace the lamp with ADC part 5211 4 Replace with fresh C batteries Obtain replacement accessories Service required Replace the lamp with AD...

Page 15: ... this product is contaminated this directive does not apply Symbols Attention Read Operating Manual for Cautions and Instructions for Use TYPE B Indicates this is a product with Type B applied parts Environment 4 F to 120 2 F 20 C to 49 C RH 95 500 hpa 1060 hpa Altitude 50 F to 120 2 F 10 C to 49 C RH 95 Max 500 hpa 1060 hpa Altitude 95 F 35 C Attention This is NOT an AP or APG apparatus Transport...

Page 16: ...e Incidental special or consequential damages Some states do not allow the exclusion or limitation of incidental special or conse quential damages so this limitation may not apply to you To Obtain Warranty Service Send item s postage paid to ADC Attn Repair Dept 55 Commerce Dr Haup pauge NY 11788 Please include your name and address phone no proof of purchase and a brief note explaining the proble...

Page 17: ... ADC UK Ltd Unit 6 PO14 1TH United Kingdom Inspected Assembled and Packaged in the U S A Made in Pakistan tel 631 273 9600 toll free 1 800 232 2670 fax 631 273 9659 www adctoday com info adctoday com IB p n 93 5215 00 rev 7 Printed in the U S A ...

Reviews: