background image

LTPH-UM-1261-01

1-1

1

Chapter

P

RODUCT

 D

ESCRIPTION

The HMS-318 L3 is a 22-slot, 3190 mechanics shelf that is capable of being managed locally or remotely. It can be 
mounted in a 19-inch rack and is fully NEBS 3 and UL-60950 complaint.

The ADC HiGain

®

 Management Shelf (HMS-318 List 3) weighs approximately 17 pounds (7.7 kg). It measures 17.3 

in. wide x 5.22 in. high x 12 in. deep (43.9 cm x 13.3 cm x 30.5 cm). These dimensions do not include the mounting 
brackets that are factory-installed to the shelf.

The HMS-318 List 3 shelf can be mounted in three different types of rack mount configurations:

• A standard (EIA or WECO) 19-inch (48.3-cm) Central Office (CO) or telco-style equipment rack (using the

mounting rack adapter brackets provided). These brackets can be positioned for either 2- or 5-inch recess.

• A standard (EIA or WECO) 23-inch (58.4-cm) Central Office (CO) or telco-style equipment rack (using the

optional Extender Bracket: EB-52). These brackets can be positioned for either 2- or 5-inch recess.

• A European Telecommunications Standards Institute (ETSI) telco-style rack mounting (using ETSI mounting

adapter brackets and hardware provided).

The HMS-318 List 3 shelf supports:

• 1.544 Mbps (T1) full-duplex transmission over two unconditioned, non-loaded copper loops

• DSX-1 interfaces at the CO and the remote end, with remote provisioning and performance monitoring

• CO power modules (LPS-300C) which provide xDSL span powering to ADC’s LoopStar

 Wi-Fi

®

 Access Point

(AP) solution.

The HMS-318 List 3 shelf is shipped with:

• Adjustable mounting brackets (as described above) that allow the shelf to be positioned in the equipment rack to

match the recess of the existing equipment (either 2- or 5-inch mounting).

• HMS-318 List 3 Shelf Rack Mounting Kit:

– 3 x 5 inch label holder (1)

– Label, HMS-318 (1)

– BNC-T female connector (1) – used with 10 BASE-2 managed systems

– 50-ohm BNC terminator (1) – used with 10BASE-2 managed systems

– #12-24 x .5 inch mounting screws (4).

• ETSI mounting hardware:

– #6-32 x 0.250 inch mounting Phillips head screws w/lock washer (8)

– M6-1.0 x14 mm mounting panhead screws (4)

• Shelf grounding kit:

– #10-32 x .5 inch mounting Hex screw w/washer (1)

– Ring terminal stud, taped 12-10 AWG (1)

– ground jumper, 2-position (1)

– Cable ties (10)

• ETSI mounting brackets (2)

• This instruction manual, 

HiGain Management Shelf (HMS-318 List 3) User Manual

, catalog number 

LTPH-UM-1261.

The following optional accessories are available:

• Extender Bracket Kit, 5.25 inches high for mounting a shelf into a 23-inch (58.4-cm) telco-style equipment rack

Summary of Contents for HiGain HMS-318 List 3

Page 1: ...HiGain Managed Shelf 19 inch 3190 Mechanic 22 Slot Managed CO Shelf HMS 318 List 3 User Manual Document Number LTPH UM 1261 01 Product Catalog HMS 318 List 3 CLEI T1MF2S04RA...

Page 2: ...mark Other product names mentioned in this practice are used for identification purposes only and may be trademarks or regis tered trademarks of their respective companies Disclaimer of Liability Info...

Page 3: ...Ports 1 13 Heat Dissipation Factors 1 13 Air Flow Guidelines 1 15 Chapter 2 Installation 2 1 Before You begin 2 1 Safety Guidelines 2 4 Mounting the HMS 318 List 3 Shelf 2 4 DSX 1 and HDSLx Connectio...

Page 4: ...Table of Contents December 20 2004 iv LTPH UM 1261 01...

Page 5: ...re 1 6 HLU Slot Wire wrap Pinouts for HDSL2 Circuits 1 9 Figure 1 7 HLU Slot Wire wrap Pinouts for HDSL4 Circuits 1 10 Figure 1 8 HLU Slot Wire wrap Pinouts for Span Powered xDSL 1 11 Figure 1 9 HMS 3...

Page 6: ...List of Figures December 20 2004 vi LTPH UM 1261 01...

Page 7: ...Table 1 4 J27 AUX RS 232 Management Port DTE 1 13 Table 2 1 HMS 318 List 3 Shelf Parts List 2 2 Table A 1 P1 DSX 1 Receive or Span Powered xDSL B IN Tip and Ring A 1 Table A 2 P2 DSX 1 Transmit or Spa...

Page 8: ...List of Tables December 20 2004 viii LTPH UM 1261 01...

Page 9: ...tary information for the HMS 318 List 3 Shelf User Manual Copies of these manuals are available online at ADC s web site at www adc com documentationlibrary or you can order copies of these documents...

Page 10: ...itive to static electricity Appendix D Specifications Provides power requirements physical dimensions recommended operational and storage environments and accessories for the HMS 318 List 3 shelf Appe...

Page 11: ...before during and after shelf installation If an electrical accident occurs proceed as follows Use caution do not become a victim yourself Turn power off to the telco style rack that the shelf is loca...

Page 12: ...s circuits Coming in contact with high electrical potential will result in death or severe personal injury IMPORTANT The shelf chassis must be properly grounded to ensure personal and equipment safety...

Page 13: ...List 3 shelf supports 1 544 Mbps T1 full duplex transmission over two unconditioned non loaded copper loops DSX 1 interfaces at the CO and the remote end with remote provisioning and performance moni...

Page 14: ...wered xDSL or ADSL pairs per module and is used as an integral part of the LoopStar Wi Fi span powered Access Point AP solution A total of 11 LPS 300C modules can be installed in the UL 60950 complian...

Page 15: ...d pin assignments see Appendix A Signal and Pin Assignments on page A 1 LoopStar LPS 300C Power Module configuration for Wi Fi Also located on the rear panel for Visual Audible Alarm Contact operation...

Page 16: ...to and from the DSLAM P2 Amphenol 50 pin Male CO PAIR 2 DS1 xDSL A IN Tip and Ring non powered xDSL signal to and from the DSLAM P3 Amphenol 50 pin Male SPAN PAIR 1 HDSL xDSL A OUT Tip and Ring bi di...

Page 17: ...nd B Figure 1 3 Input Power Terminal Block TB1 HMS 318 List 3 Shelf Input Power Connections The input power terminal block supports split 48V battery power bussing Slots 1 through 11 on the HMS 318 Li...

Page 18: ...off can be achieved by pressing the ACO button on the front panel of the Management Unit for example HMU 319 or by connecting the ACO pin 22 on the HMS 318 List 3 shelf Alarms wire wrap field see Figu...

Page 19: ...cator of the CO alarm system MAJ VIS Major Visible There is a major alarm active on the HMS 318 List 3 shelf Connect this relay to the major alarm visual indicator of the CO alarm system MIN AUD Minor...

Page 20: ...connectors through the HMS 318 List 3 shelf s rear panel wire wrap pins 0 045 inch square 1 14 mm Straps for cable dressings and a protective Lexan rear cover are provided with each shelf Figure 1 5...

Page 21: ...m when activated Minor alarm output is normally floating 0 to 60V maximum and a ground 10 ma maximum 5 Vdc for HLU 319 List 2D when activated Notes System Alarm DSX 1 Tip IN DSX 1 Tip 1 OUT DSX 1 Ring...

Page 22: ...o the LoopStar LPS 300C L1 Power Module Technical Practice catalog number SCP LPS300 010 for installation initialize and power up information ATTENTION To ensure against damage to electronic component...

Page 23: ...el for xDSL circuits Figure 1 8 HLU Slot Wire wrap Pinouts for Span Powered xDSL xDSL A IN xDSL B IN A B C D E F J H Ground GND xDSL A OUT xDSL B OUT Management Bus Frame Ground 48 Vdc Battery Fuse Al...

Page 24: ...gement Ports Table 1 3 J26 RS 232 X 25 Management Port DTE Note The HMU 319 requires that Data Set Ready DSR be asserted by the connected Data Communications Equipment DCE in order to establish commun...

Page 25: ...eep individual CO equipment shelf with open faced mountings for natural convection cooling The maximum heat dissipation for open faced natural convection cooled mountings is limited to 134 7 Watts per...

Page 26: ...ney heating effect see Air Flow Guidelines on page 1 15 for further information about cooling the HMS 318 List 3 shelf Outdoor cabinet applications require forced air to ensure proper cooling Figure 1...

Page 27: ...oo warm an over temperature condition within the rack and the shelves that occupy it can occur The site should also be as dust free as possible Dust tends to clog the shelves reducing the flow of cool...

Page 28: ...Chapter 1 Product Description December 20 2004 1 16 LTPH UM 1261 01...

Page 29: ...g spaces or WECO with 2 in mounting spaces where the HMS 318 List 3 shelf will be housed Determine the location of any existing shelves and their interconnections including communications and power Th...

Page 30: ...ur HMS 318 List 3 shelf You will need the packaging materials in the future if you move or ship your HMS 318 List 3 shelf Check 9 Item Quantity Catalog Part No Installer Initial HiGain Management Shel...

Page 31: ...g or ESD preventive wrist strap 2 Phillips head screwdriver 1 Phillips head screwdriver Straight slot head screwdriver Cable preparation tools A 5 16 inch open end wrench Tape measure Wire strippers A...

Page 32: ...utions must be followed to ensure safety They are Never wear loose clothing jewelry such as rings bracelets or chains or other items that could get caught in the shelf housing during handling and use...

Page 33: ...ng the position of the brackets from a 2 or 5 inch recess mounting or vice versa ensure that you place the appropriate hardware screws washers and so on you remove in a convenient location for re asse...

Page 34: ...As mentioned in Chapter 1 Product Description on page 1 1 and Mounting the HMS 318 List 3 Shelf on page 2 4 the adapter brackets are attached to the HMS 318 List 3 shelf at the factory for a 19 inch t...

Page 35: ...nes on page xi and the Special Rack Mounting Precautions on page 2 4 before installing the HMS 318 List 3 shelf in the telco style equipment rack Step Action 1 Locate the telco style equipment rack po...

Page 36: ...wered xDSL connections to the HMS 318 List 3 shelf ensure that the Main CO power breaker is off Otherwise severe injury to the installer or damage to the unit may result Step Action 1 Complete one of...

Page 37: ...dure To connect the Bonding Safety ground to the HMS 318 List 3 Shelf complete the following steps IMPORTANT Before making connections to the HMS 318 List 3 shelf ensure that the Main CO power breaker...

Page 38: ...ug location aligning the hole Insert the ground lug screw 12 Hexhead through the locking washer and then through the hole in the ground lug and the ground lug location on the HMS 318 List 3 Shelf Ensu...

Page 39: ...st 3 shelf are powered by the 48VA bus Slots 12 through 22 are powered by the 48VB bus In the HMU HLU configuration the HMU 319 is diode OR ed to both power busses to guard against power failure in th...

Page 40: ...shelf temperature exceeds 45 C 1 C and deactivates the relay when the temperature drops below 35 C 1 C If the temperature exceeds 77 C 1 C a critical alarm is also generated The critical alarm resets...

Page 41: ...c wrist straps connected to the ESD Jack located on the right adapter bracket see Figure 1 on page 3 when inserting a circuit card Avoid touching components on the circuit card Step Action 1 Hold the...

Page 42: ...of the circuit card toward you Align the top and bottom edges of the LPS 300C with the HMS 318 List 3 shelf slot guides 2 Slide the LPS 300C Power Module into its respective slot 3 Press the LPS 300C...

Page 43: ...e Table A 4 on page A 5 Connector P1 DSX 1 Receive or Span Powered xDSL xDSL B IN Table A 1 provides signal and pin assignment information for making DSX 1 receive or Span Powered xDSL B IN circuit co...

Page 44: ...ctions to the HMS 318 List 3 shelf Table A 2 P2 DSX 1 Transmit or Span Powered xDSL A IN Tip and Ring 14 Ring 40 15 Tip 15 Ring 41 16 Tip 16 Ring 42 17 Tip 17 Ring 43 18 Tip 18 Ring 44 19 Tip 19 Ring...

Page 45: ...Tip 9 Ring 35 10 Tip 10 Ring 36 11 Tip 11 Ring 37 12 Tip 12 Ring 38 13 Tip 13 Ring 39 14 Tip 14 Ring 40 15 Tip 15 Ring 41 16 Tip 16 Ring 42 17 Tip 17 Ring 43 18 Tip 18 Ring 44 19 Tip 19 Ring 45 20 Tip...

Page 46: ...n Powered xDSL xDSL A OUT connections to the HMS 318 List 3 shelf Table A 3 P3 HDSL Span 1 or Span Powered xDSL A OUT Tip and Ring Cable Pin Number Slot Card Slot Pin Number 26 1 Tip 1 Ring 27 2 Tip 2...

Page 47: ...SL B OUT connections to the HMS 318 List 3 shelf Table A 4 P3 HDSL Span 1 or Span Powered xDSL A OUT Tip and Ring 18 Ring 44 19 Tip 19 Ring 45 20 Tip 20 Ring 46 21 Tip 21 Ring 47 22 Tip 22 Ring Cable...

Page 48: ...4 A 6 LTPH UM 1261 01 12 Ring 38 13 Tip 13 Ring 39 14 Tip 14 Ring 40 15 Tip 15 Ring 41 16 Tip 16 Ring 42 17 Tip 17 Ring 43 18 Tip 18 Ring 44 19 Tip 19 Ring 45 20 Tip 20 Ring 46 21 Tip 21 Ring 47 22 Ti...

Page 49: ...C Color Code Pair Number Tip Ring 1 White Blue 2 White Orange 3 White Green 4 White Brown 5 White Slate 6 Red Blue 7 Red Orange 8 Red Green 9 Red Brown 10 Red Slate 11 Black Blue 12 Black Orange 13 Bl...

Page 50: ...Appendix B Standard PIC Color Code December 20 2004 B 2 LTPH UM 1261 01...

Page 51: ...nce measurement should be between 1 and 10 Mohms STORING CIRCUIT CARDS Spare circuit cards must be left in the original shipping container until required To prevent damage to circuit cards while they...

Page 52: ...eep the circuit cards in their protective bags Step Action 1 Remove any front panel cables from the circuit card 2 Grasp the circuit card at the top or bottom ejector tab or the built in thumb hold an...

Page 53: ...sions HxWxD 5 22 in x 19 in x 12 in 13 3 cm x 48 3 cm x 30 5 cm without mounting brackets Weight 17 lb 7 7 kg Capacity 1 HMU Management Module and 22 HLU Modules or 22 ELU Modules or 11 LPS 300C Power...

Page 54: ...ng in either 19 inch 48 3 cm or 23 inch 58 4 cm bays Brackets for mounting in ETSI rack Accessories Available Extender Bracket Kit available in three colors EB 52 gray EB 52B black EB 52P putty a If f...

Page 55: ...nitoring upstream or downstream Power Monitoring and Remote Surveillance Service Maintenance Agreements and Systems Operation ADC Technical Assistance Center 800 366 3891 Email wsd support adc com Tec...

Page 56: ...Appendix E Product Support December 20 2004 E 2 LTPH UM 1261 01...

Page 57: ...ETSI European Telecommunications Standard Institute F FCC Federal Communications Commission FGND Frame Ground G G SHDSL Single pair High speed Digital Subscriber Line G 703 ITU T Recommendation for p...

Page 58: ...ces port P PIC Plastic Insulated Conductor R RCV Receive RMA Return Material Authorization RX Receive S SYS ID System Identifier alarm T T1 1 544 Mbps data rate North American V VIS Visible alarm W WE...

Page 59: ...nty is determined by your service agreement Refer to the ADC Warranty Software Handbook for additional information or contact your sales representative or Customer Service for details Modifications Th...

Page 60: ...Minneapolis MN 55440 1101 USA For Technical Assistance Tel 800 366 3891 HiGain Managed Shelf 19 inch 3190 Mechanic 22 Slot Managed CO Shelf HMS 318 List 3 User Manual Document Number Product Catalog H...

Reviews: