14
American Dryer Corp.
WFR 112807 - 15
Gas Specifications for Dryers Going to Rest of the World
***
Gas Type and
Nominal Heating Value
Supply
Pressure
**
Gross Heat Input
per Pocket/Tumbler
Orifice Size
**
Orifice
(Injector)
Qty. per
Pocket/
Tumbler
Burner
Pressure
B tu /f t
3
in WC
Btu/hr
kW
DMS
mm
in WC
Natural
1,000
7.0-13.0
64,000
18.74
23
3.912
1
3.5
*
Propane
2,500
11.0
64,000
18.74
42
2.375
1
10.5
Gas Specifications for Dryers Going to CE Countries
**
Gas
Type
Nominal
Heating Value
Supply
Pressure
***
Gross Heat Input
Per Pocket/Tumbler
Fuel
Consumption
Per Pocket/
Tumbler
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
B tu / ft
3
mb
Btu/hr
kW
DMS
mm
mb
Natural (I
2H
/I
2E
)
1,000
15-30
55,000
16.12
1.556 M
3
/H
22
3.988
1
6.9
Natural (I
2L
)
830
20-35
55,000
16.12
1.874 M
3
/H
22
3.988
1
9.5
Natural (I
2ELL
)
830
15-30
55,000
16.12
1.874 M
3
/H
22
3.988
1
9.5
*
Natural ( I
2E+
)
1,000
20
55,000
16.12
1.556 M
3
/H
31
3.048
1
—
830
25
55,000
16.12
1.874 M
3
/H
31
3.048
1
—
*
Butane (I
3+
)
3,175
28-30
55,000
16.12
1.161 kg/H
48
1.93
1
—
*
Propane (I
3+
)
2,500
37
55,000
16.12
1.161 kg/H
48
1.93
1
—
Butane (I
3B/P
)
3,175
28-30/50
55,000
16.12
1.161 kg/H
44
2.184
1
18.1
Propane (I
3P
)
2,500
28-30/50
55,000
16.12
1.161 kg/H
44
2.184
1
24.9
Heat Input / Gas Consumption / Orifice (Injector) Data
Shaded areas are stated in metric equivalents
*
Gas valve’s internal regulator disabled.
**
Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
!
WARNING
(CE Dryers Only)
This appliance must only be operated with the gas
type indicated on the dryer’s data plate. If the
appliance is converted (gas type changed), a data
plate amendment must be obtained from American
Dryer Corporation for CE approved units.
Shaded areas are stated in metric equivalents
*
Gas valve’s internal regulator disabled.
**
Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
*** Nominal supply pressure.
For Australia, refer to data plate.
Shaded areas are stated in metric equivalents
* Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Gas Connections
Inlet connection ..... 1/2” N.P.T.
3/8” B.S.P.T. (CE and Australian dryers)
Inlet supply size .... 1/2” Diameter Pipe (minimum)
Gas Specifications for Dryers Going to Australia
*
Gas
Type
Supply
Pressure
Gross Heat Input
Per Pocket/
Tumbler
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
kPa
MJ /h
DMS
mm
kPa
Natural
1.7-3.2
58.03
22
3.988
1
0.69
Propane
2.75
58.03
44
2.184
1
2.49