LTPS-UM-8013-03
Local
Configuration
D3LX CO and RMT Modules
August 30, 2002
23
L
OCAL
C
ONFIGURATION
A D3LX system can be configured locally by an SCU (version 3.7 or later) with a D3LX CO module in an LEC.
It can also be configured remotely by a D3RCAM with a D3LX RMT module installed in a remote chassis. See
“Remote Configuration” on page 33
for the procedure configuring remotely using the D3RCAM.
The following details the local configuration procedure.
C
ONFIGURING
THE
D3LX S
YSTEM
T
HROUGH
THE
SCU
Use the craft interface system menu to view or edit the configuration for
each D3LX module in the chassis. This menu can also be used to equip,
provision, assign thresholds, and assign service state.
1
Connect a maintenance terminal to the craft port on the SCU front panel and log on to the craft interface
system as described in
“Connecting a Maintenance Terminal to the SCU Craft Port” on page 19
2
From the Main menu, select
3. Unit Configuration
.
3
From the Unit Configuration menu, select
4. D3LX Configuration
.
The D3LX Configuration appears as shown in
Figure 13.
D3LX Configuration Screen
See
“Navigating Through Craft Interface Menus” on page 22
for detailed information on making
selections.
3. Unit Configuration
4. D3LX Configuration