9002

Automatic Sphygmomanometer

AMERICAN DIAGNOSTIC CORPORAT I O N

User’s

Manual

A D C
55 Commerce Drive
Hauppauge, NY 11788

ADC (UK) Ltd.
Unit 6, PO14 1TH
United Kingdom

Inspected in the U.S.A.

Made in Japan

tel: 631-273-9600, 1-800-232-2670

fax: 631-273-9659

w w w. a d c t o d a y. c o m

email: info@adctoday. c o m

IB p/n 93-9002-00 rev 3                                                                                         Printed in Japan

0 1 9 7

Summary of Contents for 9002

Page 1: ...ION User s Manual ADC 55 Commerce Drive Hauppauge NY 11788 ADC UK Ltd Unit 6 PO14 1TH United Kingdom Inspected in the U S A Made in Japan tel 631 273 9600 1 800 232 2670 fax 631 273 9659 www adctoday com email info adctoday com IB p n 93 9002 00 rev 3 Printed in Japan 0197 ...

Page 2: ...easure a patient s blood pressure and pulse automatically In manual mode it allows you to use the time proven auscultatory method to obtain blood pressure readings Thank you for your patronage It is indeed our pleasure to serve you Sincerely American Diagnostic Corp 2006 AMERICAN DIAGNOSTIC CORP FOR QUESTIONS COMMENTS OR SUGGESTIONS CALL TOLL FREE 1 800 ADC 2670 2006 ADC All rights reserved No one...

Page 3: ...with the date of delivery 2 The entire sphygmomanometer is warranted for one year 3 Cuff bladder and coiled tubing are warranted for two years 4 The manometer is warranted to remain accurate to 3mmHg over its full range when compared to a reference standard for life What is Covered Repair or replacement of parts and labor What is not covered Transportation charges to and from ADC Damages caused by...

Page 4: ... automated sphygmomanometers The 9002 digital ADC e sphygTM 2 sphygmomanometer has the ability to function according to its specifications in the presence of common arrhythmia such as atrial or ventricular premature beats or atrial fibrillation Specifications Operating Principle Oscillometric method Indicator 300 digits column LCD and 10 digits segment LCD Pressure Indicating Range 0 to 300 mmHg c...

Page 5: ...t drape tubing around your neck Caution The standard material used for the bladder inflation bulb and coiled tubing is natural rubber latex and it may cause allergic reactions Latex free options are available Note To obtain the greatest accuracy from your blood pressure instrument it is recommended that the instrument be used within a temperature range of 50 F 10 C to 104 F 40 C with a relative hu...

Page 6: ...will accommodate that of approximately 13 5 to 20 04 inches 34 3 to 50 9 centimeters Cuff Sizes Manual Mode In manual mode any of ADC s 5 cuff sizes infant child adult large adult or thigh may be used on any patient Operation with AC Adapter or Rechargeable Battery The digital ADC e sphygTM 2 sphygmomanometer is powered by either an AC Adapter or rechargeable nickel metal hybrid NiMH battery both ...

Page 7: ...TOR BATTERY COMPARTMENT COVER BATTERY PLUG 9002W Wall Unit Parts Tools ADC Item Item no 1 e sphygTM 2 9002 2 6mm Allen Wrench 752M 116 3 Wall Bracket 952 103 4 Wall Basket with 3 screws 3 mollys 952 025 5 Coiled tubing 885 6 Mounting Bolt Washer 1 972 101 7 Connector 9002 2 8 Connector Male 891M 9 Connector Female 891F 10 AdcuffTM Bladder 850F 11 2 Screws for wall bracket 952 104 12 2 Mollys for w...

Page 8: ...ed and allowed to air dry NEVER iron When storing the device do not place heavy objects on it and do not coil BLADDER TUBE too tightly When the unit has been stored at a temperature below the freezing point keep it for at least 1 hour in a warm place before using Remove the battery if the device is to be stored for an extended period of time Keep the batteries out of the reach of children Caution ...

Page 9: ... turns green as it indicates the battery is charged The color of the AC INDICATOR may switch to green and return to orange if the 9002 is operated while charging battery however it does not indicate a problem Fig 1 Fig 2 Fig 3 ADAPTER PLUG BATTERY PLUG Error Displays and Troubleshooting If you cannot get correct measurement with the methods above do not tamper with the internal mechanism Contact y...

Page 10: ...her START STOP button or SET MEMORY button is pressed It is recommended to activate the device by pressing SET MEMORY button since the device could start inflation if START STOP button is pressed Press START STOP button again and stop inflation if the cuff is not wrapped around arm Error Displays and Troubleshooting ERROR SYMBOL SYMPTOM CAUSE REMEDY LOW BATTERY Change the battery Only a Battery is...

Page 11: ...ed to the the patient maximum pressure because stays still during of movement of body etc measurement MEASUREMENT ERROR Make sure the Measurement could not be patient remains made because of moving or still and quiet talking during measurement during measurement INFLATION ERROR Reinsert AIR PLUG and make AIR PLUG is not correctly sure that it is securely inserted inserted Make sure that the patien...

Page 12: ...rge 6mm allen key Figure 4 5 Connect tubing as noted in Wall configuration 4 6 Adjust height of manometer by loosening adjusting knob and raising or lowering inner pole until gauge is at desired height Tighten adjusting knob by hand Figure 5 Figure 4 Figure 1 Figure 2 Figure 3 Figure 5 How to Assemble Mobile Model MemoryFunction Measured result obtained in AUTO mode is automatically saved in the m...

Page 13: ...down START STOP button once deflation has started and the cuff is pressurized again Pressurization will continue while the button is pressed Pressure does not exceed 290 mmHg Press START STOP button when blood pressure is taken and air is rapidly exhausted from the cuff Air is also rapidly exhausted from the cuff when pressure descends to 30 mmHg Turn off the device by pressing O side of MAIN POWE...

Page 14: ...ings may result If your patient is wearing a shirt that might restrict circulation in his her upper arm or he she rolls his her sleeve up over the upper arm the blood flow will be restricted preventing accurate measurement ARM CIRCUMFERENCE CUFF SIZE 10 28 to 16 1 inches 26 1 to 40 9 cm ADULT 13 5 to 20 04 inches 34 3 to 50 9 cm LARGE ADULT 7 48 to 10 71 inches 19 0 to 27 2 cm CHILD Press START ST...