Appendix B: Additional Information
150-506-100-03
30
March 28, 2000
HRE-506 List 1 and List 2
5
Turn the valve until it is hand tight with compression against the gasket material.
The housing is now ready to be pressurized either through the Schrader air valve stem, which is part of the
T-valve and accepts a standard tire valve chuck, or through the air valve stem located at the opposite end of
the T-valve, as shown in
.
6
Remove the two-unit desiccant bag from the shipping carton and place it in the HRE-506 unit.
7
Attach a plastic tube (
1
/
4
-inch ID x
3
/
8
-inch OD, not included) to the
1
/
4
-inch air inlet protrusion of the air
intake valve.
8
Secure the tube to the valve with the hex bolt and ferrule.
Spare Connections
The HRE-506 stub has three spare pairs and one order wire pair. One spare pair and the order wire pair are in the
blue group. The remaining two spares are in the orange group.
Order Wire Connections
The external order wire pair access port is connected to its surge protector by the red-brown jumper wire. The
black and white order wire pair also terminates on this protector. This permits access to the order wire without
opening the enclosure. Simply unscrew the order wire protective cap, as shown in
, to expose
the order wire terminals.
The tube and fitting assembly is also called an Express Air Connection Fitting, which is not
supplied by ADC.