150-454-111-06
Overview
HRE-454
February 25, 2000
3
Figure 1.
Typical HRE-454 List 5 and List 6 Application
Doubler, Line, and Remote Unit
All HRE-454 list numbers use the following doubler, line, and remote units. See the respective figure number
listed in the table next to the unit to view pinout assignments for that unit. Refer to
for HiGain pair assignments and
for a diagram listing all the HRE-454 wiring interfaces.
Table 1.
Doubler, Line, and Remote Unit Pin Assignment Figure Numbers
Unit
Figure and Page
Number
Description
Wire List
HRU-412
Remote module for 2 pair (HDSL), T1 (1.544 Mbps)
service.
ERU-412 List 2
Remote module for 2 pair (HDSL), E1 (2.048 Mbps)
service, G.703, 120
Ω
balanced.
HRU-512
Remote module for 1 pair (HDSL), T1 fractional (128 to 786
kbps) service.
HRU-612
Remote module for 1 pair (HDSL), T1 (1.544 Mbps)
service.
HDU-451,
HDU-404, and
EDU-451
Doubler module for 2 pair (HDSL), T1 (HDU-451, HDU-404)
or E1 (EDU-451) service.
HLU-431 List 1D,
HLU-432
Line Unit Module for 2 pair (HDSL) T1 (1.546 Mbps)
service.
HRU-402
Remote unit for 2 pair (HDSL), T1 (1.544 Mbps) service.
H2TU-R-402
Remote unit for 1 pair (HDSL2), T1 (1.544 Mbps) service.
Only the HRE-454 List 5 and List 6 units are wired to provide -48 Vdc power to their four slots.