Site Selection
Use the following guidelines in selecting a site:
¤
(110 VAC only) The installation site should include a
grounded 110 VAC power receptacle.
¤
The standard specifications for the following cable distances
as prescribed by the standards documents are:
Interface
Suggested Maximum Cable Length
V.35
50 FEET
EIA-530
200 FEET
NOTE:
At lower than maximum speed with proper cabling,
longer distances can be achieved. For more
information please refer to the application note on
cabling available from your Kentrox representative.
¤
The site should provide enough room for adequate
ventilation and cable routing. Allow at least 4.0 inches at
the rear of the unit for cables and air flow. Do not block any
of the air vents on the unit. Allow clearance for operation
and maintenance.
¤
The site should provide a stable environment. The operating
area should be clean and free from extremes of temperature,
humidity, shock and vibration.
¤
Relative humidity should stay between 0 and 95%. Do not
operate the unit at an altitude greater than 10,000 feet.
If any of these operating limits are exceeded, the unit may not operate
properly.
After Unpacking
Inspect the unit for any signs of damage. Report any damage to the
carrier and contact your Kentrox customer representative. Retain all
packing material in case you need to move or ship the unit in the
future.