![ADB Safegate RELIANCE Navigator User Manual Download Page 35](http://html1.mh-extra.com/html/adb-safegate/reliance-navigator/reliance-navigator_user-manual_2847399035.webp)
5.0 Parts
Ordering Code
Touchscreen
1 = One 12-inch PC (in tower only)
2 = One 15-inch PC (in tower only)
3 = Two 12-inch PC (in tower and vault)
4 = Two 15-inch PC (in tower and vault)
Communications Package
1 = No communication extension
1
2 = Multi-mode fiber optic communication
extension
2
3 = Single-mode fiber optic communication
extension
2
4 = 2.4 GHz radio communication extension
UPS
1 = External UPS with 15-minute backup
3
Alarm Package
1 = External speakers at touchscreen station
CCR Control
1 = No B1 or B10 control provided
4
2 = Separate B1 or B10 control provided
5
Remote Dial-In
1 = No dial-in
2 = Remote dial-in diagnostic included
Extreme Temperature Kit
1 = No electric heater
2 = Electric heater mounted in PLC Cabinet
6
Second PC Mounting Option
0 = External mounting of second PC
7
1 = Internal mounting of second PC
8
Notes
•
All fiber optic cables should be terminated with ST style connectors. Fiber
optic cable and connectors not provided by ADB SAFEGATE.
1
PLC cabinet must be within 9
ft
of Touchscreen/PC.
2
Fiber optic cable supplied by others, multi-mode wavelength 1300
nanometers, single-mode 1310 nanometers.
3
For use with 120 VAC 60 Hz operation only.
4
Use this option if all CCRs present do not require B1 (5-Step) or B10 (3-
Step) to activate the low -intensity step.
5
Use this option if any CCRs present require both B1 (5 -Step) or B10 (3-
Step) and CC to activate the low -intensity step.
6
Extreme Temperature Kit includes 200 W heater tha t allows a decrease in
minimum operating temperature to -18 °C (0 °F).
7
Use this option if it is desired to mount the vault touchscreen outside of
the PLC cabinet (i.e. on a desk).
8
Use this option if it is desired to mount the vault touchscreen inside the
PLC cabinet.
44A7675 - X X 1 1 X X - X X 0