If the lamps do not illuminate and the onboard Green LED (D12) does not flash at a 1 second rate (heartbeat), then there
is a fault on the power supply board or incoming power. Remove the input power and check the input wiring for opens or
shorts.
•
Make certain you replace the cover after you are done checking the power supply.
Figure 15: Halogen Sign Power Supply 44A7199-200 with Cover Removed
Refer to
for the power supply LEDs.
Table 14: Halogen Sign Power Supply LEDs
LED
Function
Green (D12)
Flashes at 120 beats per minute when power is applied to the power
supply board.
Red (D13)
Indicates the power supply board assembly is not able to maintain a
regulated lamp current. This also indicates that at least one lamp is
burnt out.
4.3.4 Halogen Lamp Power Supply Connections
If you replace the power supply board, refer to
for the power supply board connections. See also
. Refer
to
Checking the Halogen Lamp Sign Power Supply
Table 15: Halogen Sign Power Supply Connections
This connector…
Connects to this device…
P1, P2
A string of up to eight 48 W primary lamps
P3, P4
A string of up to eight 48 W backup lamps
P12, P13
The output of a 6.6 A isolation transformer providing input power for
the halogen sign
P7, P8, P9
Optional lamps-out indicator
L-858 AGSF
Maintenance
32
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for L-858 AGSF Series
Page 1: ...L 858 AGSF Incandescent Airfield Guidance Signs FAA User Manual 96A0286 Rev AT 2020 09 16 ...
Page 2: ......
Page 8: ...L 858 AGSF List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...L 858 AGSF List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 16: ...L 858 AGSF Safety 6 Copyright ADB Safegate All Rights Reserved ...
Page 56: ......