48
GB
No. Fault
Possible cause
Possible solution
7
Master User is already
registered.
- Master User is already
stored in ADAX SET’s internal
memory.
- Change the Master number
(see SMS command list, page 41).
- Revert to default settings
(see SMS command list, page 41).
8
Invalid format.
Check and try again.
- Incorrect command format. Read the user guide.
9
Sorry, you are not
authorised to use this
command.
- Extra user is using incorrect
code or is attempting to use
a function not available to
extra users.
Check that you have the correct code
(see
point 2, page 39)
10 No SMS response
- Pay-as-you-go account
balance is empty.
- Inactive/deactivated
SIM-card.
- No GSM connection.
- Power supply disconnected.
- Incorrect SMS command.
SIM-card.
Top-up account balance.
Contact your service provider.
Check power supply.
Check SMS command – see user guide.
If using an old SIM-card with information
stored in its memory, deleting this
information may help.
11
SMS response with
following content:
Temp: N/A
- Temperature sensor not
installed.
- Temperature sensor
incorrectly installed
Check that temperature sensor is attached.
Check that temperature sensor is pushed
fully in place.
NOTE!
If the problem is not solved by any of the suggestions in this
checklist, you should refer to authorised service personnel at you local
dealer, or the manufacturer:
13) Technical specifications:
Power supply:
220-240 V
~
50HZ
Power output:
16 Amp, recommended max. 3000W
Operating temperature:
Min. -10°C / Max. +50°C
Storage temperature:
Min. -20°C / Max. +60°C
Humidity:
10–90%, without condensation
Communication protocol:
GSM PHASE 2/2+ (including data)
Data interface:
GSM SIM 1.8V/3.0V connection
Temperature sensor:
–10°C/ +50°C
GSM network:
EGSM900, DCS1800
Print # 62669
110612