Adaptive heating start
This feature will measure time required to heat up to a certain temperatures and pre-starts heating to reach target
temperature at required time.
If enabled, it will start heating earlier in P1 and P2 modes.
If heater was turned off, measured values will be erased. Heater will collect values again.
Time is always measured, so environment changes will be adapted.
By default, this feature is disabled.Factory reset will disable this feature too.
Enable/Disable adaptive heating start:
1. Select Manual mode (Refer “Changing mode”).
2. Turn control knob to 15°C.
3. Press and release knob twice during 1 second indicated by.
will light up if adaptive heating is enabled.
will light up if adaptive heating is disabled.
4. Turn control knob to the left to disable ( LED will light up).
Turn control knob to the right to enable ( LED will light up).
5. Press control knob once to confirm selection, indicated by.
6. Adjust required temperature.
Resetting the radiator to factory settings
This process resets all radiator settings (programmes and services) to the factory settings so it can be set-up as new.
Factory settings
1.
.
Turn the control dial to the hand symbol – Press to confirm
2.
.
Turn the control dial to 11°C
3.
.
Press the control dial in for 1 second two times – The green and red lights will blink
4.
.
Press and hold in the control dial for 3 seconds until the green light blinks
The radiator is now reset to its factory settings.
Follow the instructions in Step 1 of the instructions to set up your radiator.
Programme P2 – Day/Week programme
Set up your own custom program / temperature for a day or week
Activate P2 – Choose Day- or Week mode
1.
.
Turn the control dial to P2 (P2 level with the LED light)
2.
.
Quickly press the control dial in two times during the course of 1 second. The green light will blink
3.
Choose Day or Week mode
a.
Turn the control dial LEFT to select WEEK MODE –
b.
Turn the control dial RIGHT to select DAY MODE –
4.
.
Press the control dial in once to confirm your choice (Day or Week) – A blinking green light confirms your choice
11
Returning to normal operation:
-
Automatically after 60 minutes.
-
If temperature rises 3 (or more) °C during 10 minutes period.
-
If control knob is pressed during
indication.
-
If control knob is turned during
indication